The number of an Acl. range 1-99 - standard acl. range 100-199 - extended acl. range 200-299 - link acl. range 300-399 - hybrid acl. range 600-699 - ipv6 hybrid acl.
Sources for this description
ZTE MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.3902.1015.26.1.2.1.1
The number of an Acl. range 1-99 - standard acl. range 100-199 - extended acl. range 200-299 - link acl. range 300-399 - hybrid acl. range 600-699 - ipv6 hybrid acl.
Identification
{1 3 6 1 4 1 3902 1015 26 1 2 1 1}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In ZTE-AN-QOSPCL-MIB, the row index zxAnAclNumber is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.3902.1015.26.1.2.1.1.<zxAnAclNumber>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
zxAnAclNumber OBJECT-TYPE
SYNTAX Integer32 (1..399 | 600..699)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The number of an Acl.
range 1-99 - standard acl.
range 100-199 - extended acl.
range 200-299 - link acl.
range 300-399 - hybrid acl.
range 600-699 - ipv6 hybrid acl."
::= { zxAnAclEntry 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The number of an Acl. range 1-99 - standard acl. range 100-199 - extended acl. range 200-299 - link acl. range 300-399 - hybrid acl. range 600-699 - ipv6 hybrid acl.
ZTE MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: zxAnAclNumber
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"zxAnAclNumber",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"1",
".",
".",
"399",
"|",
"600",
".",
".",
"699",
")",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"The number of an Acl. range 1-99 - standard acl. range 100-199 - extended acl. range 200-299 - link acl. range 300-399 - hybrid acl. range 600-699 - ipv6 hybrid acl.\"",
"::=",
"{",
"zxAnAclEntry",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
1,
399
],
[
600,
699
]
]
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The number of an Acl. range 1-99 - standard acl. range 100-199 - extended acl. range 200-299 - link acl. range 300-399 - hybrid acl. range 600-699 - ipv6 hybrid acl."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. ZTE support.
Module: ZTE-AN-QOSPCL-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['MacAddress', 'RowStatus', 'DisplayString', 'TruthValue', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Counter32', 'IpAddress', 'Integer32'], 'ZTE-AN-TC-MIB': ['zxAn'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressPrefixLength']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3902.1015.26.1.2.1.2 | zxAnAclName | 0 | 0 | |
| 1.3.6.1.4.1.3902.1015.26.1.2.1.30 | zxAnAclRowStatus | 0 | 0 |