Reference record for OID 1.3.6.1.4.1.3955.5.5.2.1


parent
1.3.6.1.4.1.3955.5.5.2 (sp2Control)
node code
1
node name
resetModule
dot oid
1.3.6.1.4.1.3955.5.5.2.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) linksys(3955) etherHub(5) sp2Hub(5) sp2Control(2) resetModule(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) linksys(3955) etherHub(5) sp2Hub(5) sp2Control(2) resetModule(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) linksys(3955) etherHub(5) sp2Hub(5) sp2Control(2) resetModule(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) linksys(3955) etherHub(5) sp2Hub(5) sp2Control(2) resetModule(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) linksys(3955) etherHub(5) sp2Hub(5) sp2Control(2) resetModule(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) linksys(3955) etherHub(5) sp2Hub(5) sp2Control(2) resetModule(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/linksys/etherHub/sp2Hub/sp2Control/resetModule
  • /iso/identified-organization/dod/internet/private/enterprises/linksys/etherHub/sp2Hub/sp2Control/resetModule
  • /iso/org/dod/internet/private/enterprise/linksys/etherHub/sp2Hub/sp2Control/resetModule
  • /iso/org/dod/internet/private/enterprises/linksys/etherHub/sp2Hub/sp2Control/resetModule
  • /iso/iso-identified-organization/dod/internet/private/enterprise/linksys/etherHub/sp2Hub/sp2Control/resetModule
  • /iso/iso-identified-organization/dod/internet/private/enterprises/linksys/etherHub/sp2Hub/sp2Control/resetModule
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/3955/5/5/2/1

    Description by mibdepot

    Writing any data value to this register is identical
    to a hardware reset. Everything is reset except the
    Source Address RAM.

    Parsed from file LINKSYS.MIB.txt
    Company: None
    Module: LINKSYS-MIB

    Description by circitor

    Writing any data value to this register is identical
    to a hardware reset. Everything is reset except the
    Source Address RAM.

    Parsed from file LINKSYS-MIB.mib
    Module: LINKSYS-MIB

    Information by oid_info

    Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.

    Information by mibdepot

    resetModule OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing any data value to this register is identical to a hardware reset. Everything is reset except the Source Address RAM." ::= { sp2Control 1 }

    Information by circitor

    resetModule OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing any data value to this register is identical to a hardware reset. Everything is reset except the Source Address RAM." ::= { sp2Control 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.3955)

    LaPolla Greg

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.3955.5.5.2.1.0 resetModule 0 0 None

    Brothers (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.3955.5.5.2.2 sp2CtlEntry 7 7 None