If set to true when netraCtRscAdminHostReset is set, then
a break will be sent to the host, causing a core dump to
be saved on the host. Otherwise, the setting of
netraCtRscAdminHostReset will cause a hardware reset.
Parsed from file SUN-SNMP-NETRA-CT-RSC-MIB.mib
Module: SUN-SNMP-NETRA-CT-RSC-MIB
netraCtRscPanicDump OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), notimpl(2147483647) } MAX-ACCESS read-write STATUS current DESCRIPTION "If set to true when netraCtRscAdminHostReset is set, then a break will be sent to the host, causing a core dump to be saved on the host. Otherwise, the setting of netraCtRscAdminHostReset will cause a hardware reset." ::= { netraCtRscConfigObjs 20 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.42.2.65.2.1.2.1 | netraCtRscGlobalPageFlag | 0 | 0 | An on(1) to this variable will enable paging for RSC alerts. An off(2) will disable paging. |
1.3.6.1.4.1.42.2.65.2.1.2.2 | netraCtRscGlobalEmailFlag | 0 | 0 | An on(1) to this variable will enable email for RSC alerts. An off(2) will disable email. |
1.3.6.1.4.1.42.2.65.2.1.2.3 | netraCtRscGlobalIPModeFlag | 0 | 0 | IP mode global flag |
1.3.6.1.4.1.42.2.65.2.1.2.4 | netraCtRscGlobalPPPFlag | 0 | 0 | serial configuration flag indicating whether PPP should be the default. |
1.3.6.1.4.1.42.2.65.2.1.2.5 | netraCtRscHostname | 0 | 0 | name of Host connected to RSC |
1.3.6.1.4.1.42.2.65.2.1.2.6 | netraCtRscCustomerInfo | 0 | 0 | Customer information used in the message generated for a pager or email alert |
1.3.6.1.4.1.42.2.65.2.1.2.7 | netraCtRscVersionBootMajor | 0 | 0 | RSC Firmware BootMonitor Revision Major Number |
1.3.6.1.4.1.42.2.65.2.1.2.8 | netraCtRscVersionBootMinor | 0 | 0 | RSC Firmware BootMonitor Revision Minor Number |
1.3.6.1.4.1.42.2.65.2.1.2.9 | netraCtRscVersionBootMicro | 0 | 0 | RSC Firmware BootMonitor Revision Micro Number |
1.3.6.1.4.1.42.2.65.2.1.2.10 | netraCtRscVersionMainMajor | 0 | 0 | RSC Core RSC Revision Major Number |
1.3.6.1.4.1.42.2.65.2.1.2.11 | netraCtRscVersionMainMinor | 0 | 0 | RSC Core RSC Revision Minor Number |
1.3.6.1.4.1.42.2.65.2.1.2.12 | netraCtRscVersionMainMicro | 0 | 0 | RSC Core RSC Revision Micro Number |
1.3.6.1.4.1.42.2.65.2.1.2.13 | netraCtRscVersionFirmwareMajor | 0 | 0 | RSC Core Firmware Revision Major Number |
1.3.6.1.4.1.42.2.65.2.1.2.14 | netraCtRscVersionFirmwareMinor | 0 | 0 | RSC Core Firmware Revision Minor Number |
1.3.6.1.4.1.42.2.65.2.1.2.15 | netraCtRscVersionFirmwareMicro | 0 | 0 | RSC Core Firmware Revision Micro Number |
1.3.6.1.4.1.42.2.65.2.1.2.16 | netraCtRscTOD | 0 | 0 | RSC time of day |
1.3.6.1.4.1.42.2.65.2.1.2.17 | netraCtRscEscape | 0 | 0 | set the first character of the 2-character escape sequence |
1.3.6.1.4.1.42.2.65.2.1.2.18 | netraCtRscHostWatchDogReboot | 0 | 0 | RSC monitors a heartbeat from the Solaris host. If this heartbeat is late, then a message will be logged, and an alarm will be se… |
1.3.6.1.4.1.42.2.65.2.1.2.19 | netraCtRscHostWatchDogTimeout | 0 | 0 | RSC monitors a heartbeat from the Solaris host. This variable indicates the maximum tolerable number of seconds between heartbeat… |