Enables the generation of a trap when the fan in the
chassis is not rotating with sufficient speed to cool the
power supplies.
Parsed from file CHS.MIB.txt
Company: cai
Module: CHS-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
uchasFanFailureTrapEna OBJECT-TYPE SYNTAX INTEGER{ enableTrap(1), disableAll(2), enableLog(3), enableAll(4) } ACCESS read-write STATUS optional DESCRIPTION "Enables the generation of a trap when the fan in the chassis is not rotating with sufficient speed to cool the power supplies." ::= { uchasTrapEnable 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.429.1.1.8.6.0 | uchasFanFailureTrapEna | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.429.1.1.8.1 | uchasModuleInsertedTrapEna | 1 | 1 | Enables the generation of a trap when a card is inserted into the chassis. This parameter is effective across all slots in the c… |
1.3.6.1.4.1.429.1.1.8.2 | uchasModuleRemovedTrapEna | 1 | 1 | Enables the generation of a trap when a card is removed from the chassis. This parameter is effective across all slots in the ch… |
1.3.6.1.4.1.429.1.1.8.3 | uchasPSUWarningTrapEna | 1 | 1 | Enables the generation of a trap when a power supply enters a warning state, such as one or more output voltages being out of ran… |
1.3.6.1.4.1.429.1.1.8.4 | uchasPSUFailureTrapEna | 1 | 1 | Enables the generation of a trap when a power supply fails and has been automatically shut down due to overvoltage, overcurrent, … |
1.3.6.1.4.1.429.1.1.8.5 | uchasTempWarningTrapEna | 1 | 1 | Enables the generation of a trap when the temperature in the chassis, as detected by the NMC, becomes excessive. |
1.3.6.1.4.1.429.1.1.8.7 | uchasEntityWatchdogTrapEna | 1 | 1 | Enables the generation of a trap when a logical networking entity in the chassis undergoes a watchdog timeout event, indicating s… |
1.3.6.1.4.1.429.1.1.8.8 | uchasEntityMgtBusFailTrapEna | 1 | 1 | Enables the generation of a trap when the SNMP proxy agent in the NMC is unable to communicate properly with a logical networking… |
1.3.6.1.4.1.429.1.1.8.9 | uchasPsuIncompatible | 1 | 1 | Enables the generation of a trap when the PSUs are not of the same ampere ratings in the chassis. Default = Enable Trap. |
1.3.6.1.4.1.429.1.1.8.10 | uchasAuxOut1OpenTrapEnable | 1 | 1 | Enables the generation of a trap when the Status of Aux Out1 changes. Default = Enable Trap. |
1.3.6.1.4.1.429.1.1.8.11 | uchasAuxOut1ClosedTrapEnable | 1 | 1 | Enables the generation of a trap when the Status of Aux Out1 changes. Default = Enable Trap. |
1.3.6.1.4.1.429.1.1.8.12 | uchasAuxOut2OpenTrapEnable | 1 | 1 | Enables the generation of a trap when the Status of Aux Out1 changes. Default = Enable Trap. |
1.3.6.1.4.1.429.1.1.8.13 | uchasAuxOut2ClosedTrapEnable | 1 | 1 | Enables the generation of a trap when the Status of Aux Out1 changes. Default = Enable Trap. |
1.3.6.1.4.1.429.1.1.8.14 | uchasCommandInitiatedEna | 1 | 1 | Enables the generation of a trap when a command has been initiated. |
1.3.6.1.4.1.429.1.1.8.15 | uchasCommandFailedInitiatedEna | 1 | 1 | Enables the generation of a trap when a command has failed to initiate. |
1.3.6.1.4.1.429.1.1.8.16 | uchasCommandCompleteEna | 1 | 1 | Enables the generation of a trap when a command has completed successfully. |
1.3.6.1.4.1.429.1.1.8.17 | uchasCommandFailedCompleteEna | 1 | 1 | Enables the generation of a trap when a command has failed to complete successfully. |