Supplies the information about the type of
Cards in the repeater stack.
There is one octet for each unit in the stack. Each
octet can have the following values:
0 : undetected(power off or non-exist)
1 : repeater card
2 : management unit
3 : bridge/management card
4 : backup management(/bridge) card
5 : powered off
6 : unknown
Value 0 indicates either the powered off card's
cardindex is higher than all of the powered on cards
or the card is non-existant.
Value 5 indicates that the card is powered off
and there are powered on card(s) with higher index
number.
Octet offset(started 0) N indicates N+1 th card information.
I.e. The first octet indicates card 1's information.
Parsed from file 3Com-fms100.mib.txt
Company: None
Module: FMS100-MIB
Supplies the information about the type of
Cards in the repeater stack.
There is one octet for each unit in the stack. Each
octet can have the following values:
0 : undetected(power off or non-exist)
1 : repeater card
2 : management unit
3 : bridge/management card
4 : backup management(/bridge) card
5 : powered off
6 : unknown
Value 0 indicates either the powered off card's
cardindex is higher than all of the powered on cards
or the card is non-existant.
Value 5 indicates that the card is powered off
and there are powered on card(s) with higher index
number.
Octet offset(started 0) N indicates N+1 th card information.
I.e. The first octet indicates card 1's information.
Parsed from file FMS100-MIB.mib
Module: FMS100-MIB
Vendor: 3Com
Module: FMS100-MIB (3Com-fms100.mib)
Type: TABULAR
Access: read-only
Syntax: OCTET STRING
( SIZE (
1..8 ) )
Automatically extracted from www.mibdepot.com
pa100RptrStackCardTypeInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Supplies the information about the type of Cards in the repeater stack. There is one octet for each unit in the stack. Each octet can have the following values: 0 : undetected(power off or non-exist) 1 : repeater card 2 : management unit 3 : bridge/management card 4 : backup management(/bridge) card 5 : powered off 6 : unknown Value 0 indicates either the powered off card's cardindex is higher than all of the powered on cards or the card is non-existant. Value 5 indicates that the card is powered off and there are powered on card(s) with higher index number. Octet offset(started 0) N indicates N+1 th card information. I.e. The first octet indicates card 1's information." ::= { pa100RptrEntry 3 }
pa100RptrStackCardTypeInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Supplies the information about the type of Cards in the repeater stack. There is one octet for each unit in the stack. Each octet can have the following values: 0 : undetected(power off or non-exist) 1 : repeater card 2 : management unit 3 : bridge/management card 4 : backup management(/bridge) card 5 : powered off 6 : unknown Value 0 indicates either the powered off card's cardindex is higher than all of the powered on cards or the card is non-existant. Value 5 indicates that the card is powered off and there are powered on card(s) with higher index number. Octet offset(started 0) N indicates N+1 th card information. I.e. The first octet indicates card 1's information." ::= { pa100RptrEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.43.19.3.1.1.1.1 | pa100RptrServiceId | 0 | 0 | This object identifies the repeater which this entry contains information. |
1.3.6.1.4.1.43.19.3.1.1.1.2 | pa100RptrClass | 0 | 0 | The pa100RptrClass is the repeater class as defined in 802.3 standard. Class I: A type of repeater set specified such that in a ma… |