The Quantum Bridge Pvc cross-connection table. This table
defines Enet, DS1, or E1 port point-to-point cross-connections within
a single OAS system. The connection can be set between two
Ethernet, two DS1 or two E1 ports.
The table has two indexes: the interface index
of the first end-point and the interface index of the
second endpoint.
Note: Connections that are listed in this table
are not reflected in the atmVclTable.
Parsed from file qbpvc.mib.txt
Company: None
Module: QB-PVC-MIB
The Quantum Bridge Pvc cross-connection table. This table
defines Enet, DS1, or E1 port point-to-point cross-connections within
a single OAS system. The connection can be set between two
Ethernet, two DS1 or two E1 ports.
The table has two indexes: the interface index
of the first end-point and the interface index of the
second endpoint.
Note: Connections that are listed in this table
are not reflected in the atmVclTable.
Parsed from file QB-PVC-MIB.mib
Module: QB-PVC-MIB
Vendor: Quantum Bridge
Module: QB-PVC-MIB
[Automatically extracted from oidview.com]
qbCrossConnPvcTable OBJECT-TYPE SYNTAX SEQUENCE OF QbCrossConnPvcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Quantum Bridge Pvc cross-connection table. This table defines Enet, DS1, or E1 port point-to-point cross-connections within a single OAS system. The connection can be set between two Ethernet, two DS1 or two E1 ports. The table has two indexes: the interface index of the first end-point and the interface index of the second endpoint. Note: Connections that are listed in this table are not reflected in the atmVclTable. " ::= { qbCrossConnPvcGroup 3 }
qbCrossConnPvcTable OBJECT-TYPE SYNTAX SEQUENCE OF QbCrossConnPvcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Quantum Bridge Pvc cross-connection table. This table defines Enet, DS1, or E1 port point-to-point cross-connections within a single OAS system. The connection can be set between two Ethernet, two DS1 or two E1 ports. The table has two indexes: the interface index of the first end-point and the interface index of the second endpoint. Note: Connections that are listed in this table are not reflected in the atmVclTable. " ::= { qbCrossConnPvcGroup 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4323.2.13.1.2.3.1 | qbCrossConnPvcEntry | 12 | 12 | An entry in the Quantum Bridge qbCrossConnPvcTable two contains a connection between the same port type of IOTs or Modules(Enet a… |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4323.2.13.1.2.1 | qbCrossConnPvcNumber | 1 | 1 | The total number of provisioned Enet to Enet, DS1 to DS1, E1 to E1 PVCs. |
1.3.6.1.4.1.4323.2.13.1.2.2 | qbCrossConnPvcLastTimeUpdate | 1 | 1 | The value of sysUpTime at the time of the last creation, deletion or modification of an entry in the qbAtmPvcTable. If the number… |