The status of the port connect entry. Changing the value of this
object from 'active' to 'destroy' will remove this entry from the
database. It will disrupt traffic between two IOT packet interfaces.
Parsed from file qbdws.mib.txt
Company: None
Module: QB-DWS-MIB
The status of the port connect entry. Changing the value of this
object from 'active' to 'destroy' will remove this entry from the
database. It will disrupt traffic between two IOT packet interfaces.
Parsed from file QB-DWS-MIB.mib
Module: QB-DWS-MIB
Vendor: Quantum Bridge
Module: QB-DWS-MIB
[Automatically extracted from oidview.com]
qbIotPortCrossConnRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of the port connect entry. Changing the value of this object from 'active' to 'destroy' will remove this entry from the database. It will disrupt traffic between two IOT packet interfaces." ::= { qbIotPortCrossConnEntry 9 }
qbIotPortCrossConnRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of the port connect entry. Changing the value of this object from 'active' to 'destroy' will remove this entry from the database. It will disrupt traffic between two IOT packet interfaces." ::= { qbIotPortCrossConnEntry 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4323.2.3.1.5.1.1.1 | qbIotPortCrossConnEndpt1IfIndex | 0 | 0 | The ifIndex of the first IOT port((end-point) for the configured IOT cross-connect. |
1.3.6.1.4.1.4323.2.3.1.5.1.1.2 | qbIotPortCrossConnEndpt2IfIndex | 0 | 0 | The ifIndex of the second IOT port(end-point) for the configured IOT cross-connect. |
1.3.6.1.4.1.4323.2.3.1.5.1.1.3 | qbIotPortCrossConnAdminStatus | 0 | 0 | The value of this object identifies the row in the ATM Traffic Descriptor Table which applies to the receive direction of this VC… |
1.3.6.1.4.1.4323.2.3.1.5.1.1.4 | qbIotPortCrossConnOperStatus | 0 | 0 | The current operational status of the connection. |
1.3.6.1.4.1.4323.2.3.1.5.1.1.5 | qbIotPortCrossConnLastChange | 0 | 0 | The value of sysUpTime at the time this connection entered its current operational state. |
1.3.6.1.4.1.4323.2.3.1.5.1.1.6 | qbIotPortCrossConnRxTrafficDescrIndex | 0 | 0 | The value of this object identifies the row of the ATM Traffic Descriptor Table which applies to the transmit direction of this c… |
1.3.6.1.4.1.4323.2.3.1.5.1.1.7 | qbIotPortCrossConnTxTrafficDescrIndex | 0 | 0 | The value of this object identifies the row in the ATM Traffic Descriptor Table which applies to the receive direction of this co… |
1.3.6.1.4.1.4323.2.3.1.5.1.1.8 | qbIotPortCrossConnName | 0 | 0 | The textual name of the connection as specified by a user. It provides a non-volatile handle for this connection. The supplied na… |
1.3.6.1.4.1.4323.2.3.1.5.1.1.10 | qbIotPortCrossConnLoopback | 0 | 0 | This object enables loopback on this IOT to IOT port enedpoint. The endpoint on which loopback is enabled is defined by qbIotPort… |
1.3.6.1.4.1.4323.2.3.1.5.1.1.11 | qbIotPortCrossConnLoopbackEndpt | 0 | 0 | This object defines loopback on the selected endpoint. |
1.3.6.1.4.1.4323.2.3.1.5.1.1.12 | qbIotPortCrossConnKind | 0 | 0 | The VCL connection type. |