Reference record for OID 1.3.6.1.4.1.4329.2.51.5.2.1.5
- parent
- 1.3.6.1.4.1.4329.2.51.5.2.1 (himMemScalingEntry)
- node code
- 5
- node name
- himMemScalingAllocated
- dot oid
- 1.3.6.1.4.1.4329.2.51.5.2.1.5
- type
- OBJECT-TYPE
- asn1 oid
-
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) siemens(4329) iandcAdmin(2) hp4khim(51) himCentralSwitchData(5) himMemScalingTable(2) himMemScalingEntry(1) himMemScalingAllocated(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) siemens(4329) iandcAdmin(2) hp4khim(51) himCentralSwitchData(5) himMemScalingTable(2) himMemScalingEntry(1) himMemScalingAllocated(5)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) siemens(4329) iandcAdmin(2) hp4khim(51) himCentralSwitchData(5) himMemScalingTable(2) himMemScalingEntry(1) himMemScalingAllocated(5)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) siemens(4329) iandcAdmin(2) hp4khim(51) himCentralSwitchData(5) himMemScalingTable(2) himMemScalingEntry(1) himMemScalingAllocated(5)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) siemens(4329) iandcAdmin(2) hp4khim(51) himCentralSwitchData(5) himMemScalingTable(2) himMemScalingEntry(1) himMemScalingAllocated(5)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) siemens(4329) iandcAdmin(2) hp4khim(51) himCentralSwitchData(5) himMemScalingTable(2) himMemScalingEntry(1) himMemScalingAllocated(5)}
- iri oid
-
- /iso/identified-organization/dod/internet/private/enterprise/siemens/iandcAdmin/hp4khim/himCentralSwitchData/himMemScalingTable/himMemScalingEntry/himMemScalingAllocated
- /iso/identified-organization/dod/internet/private/enterprises/siemens/iandcAdmin/hp4khim/himCentralSwitchData/himMemScalingTable/himMemScalingEntry/himMemScalingAllocated
- /iso/org/dod/internet/private/enterprise/siemens/iandcAdmin/hp4khim/himCentralSwitchData/himMemScalingTable/himMemScalingEntry/himMemScalingAllocated
- /iso/org/dod/internet/private/enterprises/siemens/iandcAdmin/hp4khim/himCentralSwitchData/himMemScalingTable/himMemScalingEntry/himMemScalingAllocated
- /iso/iso-identified-organization/dod/internet/private/enterprise/siemens/iandcAdmin/hp4khim/himCentralSwitchData/himMemScalingTable/himMemScalingEntry/himMemScalingAllocated
- /iso/iso-identified-organization/dod/internet/private/enterprises/siemens/iandcAdmin/hp4khim/himCentralSwitchData/himMemScalingTable/himMemScalingEntry/himMemScalingAllocated
- iri by oid_info
- /ISO/Identified-Organization/6/1/4/1/4329/2/51/5/2/1/5
Description by circitor
This field displays the maximum number of memory elements that once have been used up during the lifetime of the switch ('high water mark'). It gives an indication how much memory was necessary at one time, so it is advised to not reduce the Maximum value below this value.
Parsed from file SIEMENS-HP4KHIM-MIB.mib
Module: SIEMENS-HP4KHIM-MIB
Information by oid_info
Vendor: Siemens AG
Module: SIEMENS-HP4KHIM-MIB
[Automatically extracted from oidview.com]
Information by circitor
himMemScalingAllocated OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This field displays the maximum number of memory elements that once have been used up during the lifetime of the switch ('high water mark'). It gives an indication how much memory was necessary at one time, so it is advised to not reduce the Maximum value below this value."
::= { himMemScalingEntry 5 }