Status in source: current.
Names: battChargerInputVoltage
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"battChargerInputVoltage",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"UNITS",
[
"literal",
"226d696c6c69766f6c747322"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The most recently measured input voltage to the battery charger. Typically, if operating on battery power, this value will approach zero. If operating on utility power, this value will approach the value of the power supplied to the device.\"",
"::=",
"{",
"batteryCharger",
"3",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
[
"UNITS",
"millivolts"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The most recently measured input voltage to the battery charger. Typically, if operating on battery power, this value will approach zero. If operating on utility power, this value will approach the value of the power supplied to the device."
],
null,
null,
null,
null
]
}
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Module: BRCM-BATTERY-MGMT-MIB
See published definition above
Module imports
{'UPS-MIB': ['PositiveInteger'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'DateAndTime', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Unsigned32'], 'BRCM-CABLEDATA-MGMT-MIB': ['cableDataMgmtMIBObjects']}
Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.