OID reference

cmDsCalTunerCoefEntry

1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1

Description

An entry defining a tuner coefficient for a given frequency at the given index for this device.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3 (cmDsCalTunerCoefTable)
Node code
1
Node name
cmDsCalTunerCoefEntry
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1
URN notation
urn:oid:1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 4413 2 99 1 1 3 2 2 3 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) broadcom(4413) cableData(2) cableDataPrivate(99) cableDataPrivateMIB(1) cableDataPrivateMIBObjects(1) cableDataEngineering(3) cablemodemEngineering(2) cmEngrDownstreamCalibration(2) cmDsCalTunerCoefTable(3) cmDsCalTunerCoefEntry(1)}
OID-IRI notation
  • /1/3/6/1/4/1/4413/2/99/1/1/3/2/2/3/1
  • /ISO/Identified-Organization/6/1/4/1/4413/2/99/1/1/3/2/2/3/1
  • /ISO/3/6/1/4/1/4413/2/99/1/1/3/2/2/3/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry
  • /iso/identified-organization/dod/internet/private/enterprises/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry
  • /iso/identified-organization/dod/internet/private/vendor-objects/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry
  • /iso/org/dod/internet/private/enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry
  • /iso/org/dod/internet/private/enterprises/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry
  • /iso/org/dod/internet/private/ldap-enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry
  • /iso/org/dod/internet/private/vendor-objects/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry
  • /iso/iso-organization/dod/internet/private/enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry
  • /iso/iso-organization/dod/internet/private/enterprises/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry
  • /iso/iso-organization/dod/internet/private/vendor-objects/broadcom/cableData/cableDataPrivate/cableDataPrivateMIB/cableDataPrivateMIBObjects/cableDataEngineering/cablemodemEngineering/cmEngrDownstreamCalibration/cmDsCalTunerCoefTable/cmDsCalTunerCoefEntry

SNMP properties

Value type
CmDsCalTunerCoefEntry
Maximum access defined by MIB
not-accessible
Status in MIB
current

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

cmDsCalTunerCoefEntry OBJECT-TYPE
    SYNTAX      CmDsCalTunerCoefEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry defining a tuner coefficient for a given frequency at the
         given index for this device."
    INDEX   { cmDsCalOffsetIndex, cmDsCalTunerCoefIndex }
    ::= { cmDsCalTunerCoefTable 1 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

An entry defining a tuner coefficient for a given frequency at the given index for this device.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

cmDsCalTunerCoefEntry · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: cmDsCalTunerCoefEntry

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "cmDsCalTunerCoefEntry",
    "OBJECT-TYPE",
    "SYNTAX",
    "CmDsCalTunerCoefEntry",
    "MAX-ACCESS",
    "not-accessible",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"An entry defining a tuner coefficient for a given frequency at the given index for this device.\"",
    "INDEX",
    "{",
    "cmDsCalOffsetIndex",
    ",",
    "cmDsCalTunerCoefIndex",
    "}",
    "::=",
    "{",
    "cmDsCalTunerCoefTable",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "CmDsCalTunerCoefEntry"
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "An entry defining a tuner coefficient for a given frequency at the given index for this device."
    ],
    null,
    null,
    [
      "INDEX",
      [
        [
          0,
          "cmDsCalOffsetIndex"
        ],
        [
          0,
          "cmDsCalTunerCoefIndex"
        ]
      ]
    ],
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4413)

Fan Frankie

Direct children (4)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.1 cmDsCalTunerCoefIndex00
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.2 cmDsCalTunerCoefFrequency00
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.3 cmDsCalTunerCoefValue00
1.3.6.1.4.1.4413.2.99.1.1.3.2.2.3.1.4 cmDsCalTunerCoefCopyFrom00