Number of seconds Receive Signal Level exceeded the RSL1 threshold in the last 15 minutes.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.4458.1000.1.6.4.1.3
Number of seconds Receive Signal Level exceeded the RSL1 threshold in the last 15 minutes.
Identification
{1 3 6 1 4 1 4458 1000 1 6 4 1 3}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: ifIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.4458.1000.1.6.4.1.3
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
winlink1000OduPerfMonAirCurrRSLThresh1Exceed OBJECT-TYPE
SYNTAX Gauge (0..900)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of seconds Receive Signal Level exceeded the RSL1 threshold in the last 15 minutes."
::= { winlink1000OduPerfMonAirCurrEntry 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Number of seconds Receive Signal Level exceeded the RSL1 threshold in the last 15 minutes.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: mandatory.
Names: winlink1000OduPerfMonAirCurrRSLThresh1Exceed
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"winlink1000OduPerfMonAirCurrRSLThresh1Exceed",
"OBJECT-TYPE",
"SYNTAX",
"Gauge",
"(",
"0",
".",
".",
"900",
")",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"Number of seconds Receive Signal Level exceeded the RSL1 threshold in the last 15 minutes.\"",
"::=",
"{",
"winlink1000OduPerfMonAirCurrEntry",
"3",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Gauge",
[
"integerSubType",
[
[
0,
900
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"Number of seconds Receive Signal Level exceeded the RSL1 threshold in the last 15 minutes."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: RADWIN-MIB-WINLINK1000
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'ifIndex']}Related source files and packages:
Vendor MIB copy from the Netdisco archive.
Module: RADWIN-MIB-WINLINK1000
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Counter', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString', 'ifIndex']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4458.1000.1.6.4.1.1 | winlink1000OduPerfMonAirCurrMinRSL | 0 | 0 | |
| 1.3.6.1.4.1.4458.1000.1.6.4.1.2 | winlink1000OduPerfMonAirCurrMaxRSL | 0 | 0 | |
| 1.3.6.1.4.1.4458.1000.1.6.4.1.4 | winlink1000OduPerfMonAirCurrRSLThresh2Exceed | 0 | 0 | |
| 1.3.6.1.4.1.4458.1000.1.6.4.1.5 | winlink1000OduPerfMonAirCurrMinTSL | 0 | 0 | |
| 1.3.6.1.4.1.4458.1000.1.6.4.1.6 | winlink1000OduPerfMonAirCurrMaxTSL | 0 | 0 | |
| 1.3.6.1.4.1.4458.1000.1.6.4.1.7 | winlink1000OduPerfMonAirCurrTSLThresh1Exceed | 0 | 0 | |
| 1.3.6.1.4.1.4458.1000.1.6.4.1.8 | winlink1000OduPerfMonAirCurrBBERThresh1Exceed | 0 | 0 |