esafeProvisioningStatusFailureFound OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"true(1) indicates that the eSAFE encountered
an error condition during the provisioning
process. An eSAFE could start a looping process
from a previous flow step after a failure,
therefore this value is retained until the
flow step that initially failed eventually
passes or is updated with another error
condition."
REFERENCE
"PacketCable Provisioning specification,
Provisioning Overview section; CableHome
specification, Provisioning Processes
section."
View at oid-info.com
true(1) indicates that the eSAFE encountered
an error condition during the provisioning
process. An eSAFE could start a looping process
from a previous flow step after a failure,
therefore this value is retained until the
flow step that initially failed eventually
passes or is updated with another error
condition.
The eSAFE device needs to reflect in the value of
'esafePsProvisioningStatusFailureFound' any recognized
errors even if it is still in the process of
provisioning, i.e., when
esafeProvisioningStatusProgress has a value of
inProgress(2).
Other eSAFE specifications provide the requirements for
those eSAFE devices with respect to this object.
Parsed from file ESAFE-MIB.mib
Module: ESAFE-MIB
Automatically extracted from Implementor\'s Guide for Recommendation ITU-T J.126 (01/05)
esafeProvisioningStatusFailureFound OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "true(1) indicates that the eSAFE encountered an error condition during the provisioning process. An eSAFE could start a looping process from a previous flow step after a failure, therefore this value is retained until the flow step that initially failed eventually passes or is updated with another error condition. The eSAFE device needs to reflect in the value of 'esafePsProvisioningStatusFailureFound' any recognized errors even if it is still in the process of provisioning, i.e., when esafeProvisioningStatusProgress has a value of inProgress(2). Other eSAFE specifications provide the requirements for those eSAFE devices with respect to this object." REFERENCE "PacketCable Provisioning specification, Provisioning Overview section; CableHome specification, Provisioning Processes section." ::={ esafeProvisioningStatusEntry 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4491.2.1.14.1.1.1.1.1 | esafeProvisioningStatusProgress | 0 | 0 | The current state of the eSAFE provisioning process. notInitiated(1) indicates that the eSAFE has not yet begun its provisioning … |
1.3.6.1.4.1.4491.2.1.14.1.1.1.1.3 | esafeProvisioningStatusFailureFlow | 0 | 0 | If esafeProvisioningStatusFailureFound is true(1) this object contains the label for the provisioning flow step in which the error… |
1.3.6.1.4.1.4491.2.1.14.1.1.1.1.4 | esafeProvisioningStatusFailureEventID | 0 | 0 | If esafeProvisioningStatusFailureFound is true(1) this object contains the eSAFE log error Event Identifier defined in the eSAFE s… |
1.3.6.1.4.1.4491.2.1.14.1.1.1.1.5 | esafeProvisioningStatusFailureErrorText | 0 | 0 | If esafeProvisioningStatusFailureFound is true(1) this object contains the eSAFE log error messages based on the eSAFE specificati… |
1.3.6.1.4.1.4491.2.1.14.1.1.1.1.6 | esafeProvisioningStatusLastUpdate | 0 | 0 | The value of the eCM docsDevDateTime when this row entry was last updated. |