Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"docsPnmCmtsUsOfdmaAQProbeNumSymToCapt",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"65535",
")",
"UNITS",
[
"literal",
"2273796d626f6c7322"
],
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This object represents the number of symbols the CMTS is to capture for the modem whose probe is being measured or the number of symbol times to measure for the idle Sid. This object cannot be changed while a capture is in progress. It will return a value of 'inconsistentValue' if set while the value of 'docsPnmCmtsUsOfdmaAQProbeMeasStatus' is set to a value of 'busy'. \"",
"REFERENCE",
"\"DOCSIS 3.1 CCAP Operations Support System Interface Specification, CM-SP-CCAP-OSSIv3.1, PNM section. \"",
"DEFVAL",
"{",
"1",
"}",
"::=",
"{",
"docsPnmCmtsUsOfdmaAQProbeEntry",
"6",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
0,
65535
]
]
]
],
[
"UNITS",
"symbols"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object represents the number of symbols the CMTS is to capture for the modem whose probe is being measured or the number of symbol times to measure for the idle Sid. This object cannot be changed while a capture is in progress. It will return a value of 'inconsistentValue' if set while the value of 'docsPnmCmtsUsOfdmaAQProbeMeasStatus' is set to a value of 'busy'."
],
[
"REFERENCE",
"DOCSIS 3.1 CCAP Operations Support System Interface Specification, CM-SP-CCAP-OSSIv3.1, PNM section."
],
null,
null,
[
"DEFVAL",
1
]
]
}