Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"docsPnmCmtsUsImpNoiseFreeRunDuration",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"65536",
")",
"UNITS",
[
"literal",
"227365636f6e647322"
],
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This attribute provides length of time to perform the measurement if the StartTriggerLevel is set to zero. This object cannot be changed while a capture is in progress. It will return a value of 'inconsistentValue' if set while the value of 'docsPnmCmtsUsImpNoiseMeasStatus' is set to a value of 'busy'. \"",
"REFERENCE",
"\"DOCSIS 3.1 CCAP Operations Support System Interface Specification, CM-SP-CCAP-OSSIv3.1, PNM section.\"",
"DEFVAL",
"{",
"60",
"}",
"::=",
"{",
"docsPnmCmtsUsImpNoiseEntry",
"2",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
0,
65536
]
]
]
],
[
"UNITS",
"seconds"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This attribute provides length of time to perform the measurement if the StartTriggerLevel is set to zero. This object cannot be changed while a capture is in progress. It will return a value of 'inconsistentValue' if set while the value of 'docsPnmCmtsUsImpNoiseMeasStatus' is set to a value of 'busy'."
],
[
"REFERENCE",
"DOCSIS 3.1 CCAP Operations Support System Interface Specification, CM-SP-CCAP-OSSIv3.1, PNM section."
],
null,
null,
[
"DEFVAL",
60
]
]
}