Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"docsPnmCmtsUsImpNoiseMeasBw",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"160",
"|",
"320",
"|",
"640",
"|",
"1280",
"|",
"2560",
"|",
"5120",
")",
"UNITS",
[
"literal",
"226b487a22"
],
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This attribute defines the bandwidth for the noise power measurement. The MeasurementBw is the -3 dB bandwidth; the occupied bandwidth is typically 1.25 times the measurement bandwidth. This object cannot be changed while a capture is in progress. It will return a value of 'inconsistentValue' if set while the value of 'docsPnmCmtsUsImpNoiseMeasStatus' is set to a value of 'busy'. \"",
"REFERENCE",
"\"DOCSIS 3.1 CCAP Operations Support System Interface Specification, CM-SP-CCAP-OSSIv3.1, PNM section.\"",
"DEFVAL",
"{",
"2560",
"}",
"::=",
"{",
"docsPnmCmtsUsImpNoiseEntry",
"6",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
160
],
[
320
],
[
640
],
[
1280
],
[
2560
],
[
5120
]
]
]
],
[
"UNITS",
"kHz"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This attribute defines the bandwidth for the noise power measurement. The MeasurementBw is the -3 dB bandwidth; the occupied bandwidth is typically 1.25 times the measurement bandwidth. This object cannot be changed while a capture is in progress. It will return a value of 'inconsistentValue' if set while the value of 'docsPnmCmtsUsImpNoiseMeasStatus' is set to a value of 'busy'."
],
[
"REFERENCE",
"DOCSIS 3.1 CCAP Operations Support System Interface Specification, CM-SP-CCAP-OSSIv3.1, PNM section."
],
null,
null,
[
"DEFVAL",
2560
]
]
}