Reference record for OID 1.3.6.1.4.1.4491.2.1.31

Parent
1.3.6.1.4.1.4491.2.1 (clabProjDocsis)
Node code
31
Node name
docsRphyCtrlMib
Numeric OID
1.3.6.1.4.1.4491.2.1.31
URN notation
urn:oid:1.3.6.1.4.1.4491.2.1.31
ASN.1 notation

{1 3 6 1 4 1 4491 2 1 31}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyCtrlMib(31)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/4491/2/1/31
  • /ISO/Identified-Organization/6/1/4/1/4491/2/1/31
  • /ISO/3/6/1/4/1/4491/2/1/31
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyCtrlMib
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyCtrlMib
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyCtrlMib
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyCtrlMib
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyCtrlMib
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyCtrlMib
  • /iso/identified-organization/dod/internet/private/vendor-objects/cableLabs/clabProject/clabProjDocsis/docsRphyCtrlMib
  • /iso/identified-organization/dod/internet/private/vendor-objects/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyCtrlMib
  • /iso/org/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyCtrlMib
  • /iso/org/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyCtrlMib
  • /iso/org/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyCtrlMib
  • /iso/org/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyCtrlMib
  • /iso/org/dod/internet/private/ldap-enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyCtrlMib
  • /iso/org/dod/internet/private/ldap-enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyCtrlMib
  • /iso/org/dod/internet/private/vendor-objects/cableLabs/clabProject/clabProjDocsis/docsRphyCtrlMib
  • /iso/org/dod/internet/private/vendor-objects/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyCtrlMib
  • Additional combinations skipped.

Descriptions

docsRphyCtrlMib — CableLabs official current and historical MIBs

This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017 Cable Television Laboratories, Inc. All rights reserved.

docsRphyCtrlMib — CableLabs official current and historical MIBs

This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2018 Cable Television Laboratories, Inc. All rights reserved.

docsRphyCtrlMib — CableLabs official current and historical MIBs

This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2019 Cable Television Laboratories, Inc. All rights reserved.

docsRphyCtrlMib — CableLabs official current and historical MIBs

This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2022 Cable Television Laboratories, Inc. All rights reserved.

docsRphyCtrlMib — CableLabs official current and historical MIBs

This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2020 Cable Television Laboratories, Inc. All rights reserved.

docsRphyCtrlMib — CableLabs official current and historical MIBs

This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2023 Cable Television Laboratories, Inc. All rights reserved.

docsRphyCtrlMib — CableLabs official current and historical MIBs

This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2021 Cable Television Laboratories, Inc. All rights reserved.

Source records

docsRphyCtrlMib

Status in source: unspecified.

Names: docsRphyCtrlMib

Technical details
{
  "smi_kind": "MODULE-IDENTITY",
  "definition": [
    "docsRphyCtrlMib",
    "MODULE-IDENTITY",
    "LAST-UPDATED",
    [
      "literal",
      "223230313730383033303030305a22"
    ],
    "ORGANIZATION",
    "\"Cable Television Laboratories, Inc\"",
    "CONTACT-INFO",
    "\" Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com\"",
    "DESCRIPTION",
    "\"This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017 Cable Television Laboratories, Inc. All rights reserved.\"",
    "REVISION",
    [
      "literal",
      "223230313730383033303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730343133303030305a22"
    ],
    "DESCRIPTION",
    "\"Initial version, created by R-OSSI-N-17.1707-2.\"",
    "::=",
    "{",
    "clabProjDocsis",
    "31",
    "}"
  ],
  "syntax_tree": [
    [
      "LAST-UPDATED",
      "201708030000Z"
    ],
    [
      "ORGANIZATION",
      "Cable Television Laboratories, Inc"
    ],
    [
      "CONTACT-INFO",
      "Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com"
    ],
    [
      "DESCRIPTION",
      "This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017 Cable Television Laboratories, Inc. All rights reserved."
    ],
    [
      "Revisions",
      [
        [
          "201708030000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
          ]
        ],
        [
          "201704130000Z",
          [
            "DESCRIPTION",
            "Initial version, created by R-OSSI-N-17.1707-2."
          ]
        ]
      ]
    ]
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-CTRL-MIB-2017-08-03.txt

    Module: DOCS-RPHY-CTRL-MIB

    Published definition
    docsRphyCtrlMib MODULE-IDENTITY 
    LAST-UPDATED    "201708030000Z" -- August 3, 2017
        ORGANIZATION    "Cable Television Laboratories, Inc" 
        CONTACT-INFO 
             "
             Postal: Cable Television Laboratories, Inc. 
             400 Centennial Parkway 
             Louisville, Colorado 80027-1266 
             U.S.A. 
             Phone: +1 303-661-9100 
             Fax: +1 303-661-9199 
             E-mail: mibs@cablelabs.com" 
        DESCRIPTION 
            "This MIB module contains the control management objects for
             the Remote PHY Device (RPD) management.
             Copyright 2017 Cable Television Laboratories, Inc.
             All rights reserved."
        	 
        REVISION "201708030000Z" -- August 3, 2017
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
        REVISION "201704130000Z" -- April 13, 2017
        DESCRIPTION 
            "Initial version, created by R-OSSI-N-17.1707-2."
    ::= { clabProjDocsis 31 }
    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-CTRL-MIB-2017-08-03.txt
    Source location: DOCS-RPHY-CTRL-MIB::docsRphyCtrlMib.
    Source version and references

    Downloaded: 2026-10-26T22:49:50.678696+00:00.

docsRphyCtrlMib

Status in source: unspecified.

Names: docsRphyCtrlMib

Technical details
{
  "smi_kind": "MODULE-IDENTITY",
  "definition": [
    "docsRphyCtrlMib",
    "MODULE-IDENTITY",
    "LAST-UPDATED",
    [
      "literal",
      "223230313930313234303030305a22"
    ],
    "ORGANIZATION",
    "\"Cable Television Laboratories, Inc\"",
    "CONTACT-INFO",
    "\" Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com\"",
    "DESCRIPTION",
    "\"This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2018 Cable Television Laboratories, Inc. All rights reserved.\"",
    "REVISION",
    [
      "literal",
      "223230313930313234303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1.\"",
    "REVISION",
    [
      "literal",
      "223230313831303138303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2.\"",
    "REVISION",
    [
      "literal",
      "223230313830343132303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730383033303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730343133303030305a22"
    ],
    "DESCRIPTION",
    "\"Initial version, created by R-OSSI-N-17.1707-2.\"",
    "::=",
    "{",
    "clabProjDocsis",
    "31",
    "}"
  ],
  "syntax_tree": [
    [
      "LAST-UPDATED",
      "201901240000Z"
    ],
    [
      "ORGANIZATION",
      "Cable Television Laboratories, Inc"
    ],
    [
      "CONTACT-INFO",
      "Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com"
    ],
    [
      "DESCRIPTION",
      "This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2018 Cable Television Laboratories, Inc. All rights reserved."
    ],
    [
      "Revisions",
      [
        [
          "201901240000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1."
          ]
        ],
        [
          "201810180000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2."
          ]
        ],
        [
          "201804120000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
          ]
        ],
        [
          "201708030000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
          ]
        ],
        [
          "201704130000Z",
          [
            "DESCRIPTION",
            "Initial version, created by R-OSSI-N-17.1707-2."
          ]
        ]
      ]
    ]
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-CTRL-MIB-2019-01-24.txt

    Module: DOCS-RPHY-CTRL-MIB

    Published definition
    docsRphyCtrlMib MODULE-IDENTITY 
    LAST-UPDATED    "201901240000Z" -- January 24, 2019
        ORGANIZATION    "Cable Television Laboratories, Inc" 
        CONTACT-INFO 
             "
             Postal: Cable Television Laboratories, Inc. 
             400 Centennial Parkway 
             Louisville, Colorado 80027-1266 
             U.S.A. 
             Phone: +1 303-661-9100 
             Fax: +1 303-661-9199 
             E-mail: mibs@cablelabs.com" 
        DESCRIPTION 
            "This MIB module contains the control management objects for
             the Remote PHY Device (RPD) management.
             Copyright 2017-2018 Cable Television Laboratories, Inc.
             All rights reserved."
        	 
        REVISION "201901240000Z" -- January 24, 2019
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1."
        REVISION "201810180000Z" -- October 18, 2018
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2."
        REVISION "201804120000Z" -- April 12, 2018
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
        REVISION "201708030000Z" -- August 3, 2017
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
        REVISION "201704130000Z" -- April 13, 2017
        DESCRIPTION 
            "Initial version, created by R-OSSI-N-17.1707-2."
    ::= { clabProjDocsis 31 }
    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-CTRL-MIB-2019-01-24.txt
    Source location: DOCS-RPHY-CTRL-MIB::docsRphyCtrlMib.
    Source version and references

    Downloaded: 2026-10-26T22:49:51.332613+00:00.

docsRphyCtrlMib

Status in source: unspecified.

Names: docsRphyCtrlMib

Technical details
{
  "smi_kind": "MODULE-IDENTITY",
  "definition": [
    "docsRphyCtrlMib",
    "MODULE-IDENTITY",
    "LAST-UPDATED",
    [
      "literal",
      "223230313930363133303030305a22"
    ],
    "ORGANIZATION",
    "\"Cable Television Laboratories, Inc\"",
    "CONTACT-INFO",
    "\" Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com\"",
    "DESCRIPTION",
    "\"This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2019 Cable Television Laboratories, Inc. All rights reserved.\"",
    "REVISION",
    [
      "literal",
      "223230313930363133303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-19.2024-1.\"",
    "REVISION",
    [
      "literal",
      "223230313930313234303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1.\"",
    "REVISION",
    [
      "literal",
      "223230313831303138303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2.\"",
    "REVISION",
    [
      "literal",
      "223230313830343132303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730383033303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730343133303030305a22"
    ],
    "DESCRIPTION",
    "\"Initial version, created by R-OSSI-N-17.1707-2.\"",
    "::=",
    "{",
    "clabProjDocsis",
    "31",
    "}"
  ],
  "syntax_tree": [
    [
      "LAST-UPDATED",
      "201906130000Z"
    ],
    [
      "ORGANIZATION",
      "Cable Television Laboratories, Inc"
    ],
    [
      "CONTACT-INFO",
      "Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com"
    ],
    [
      "DESCRIPTION",
      "This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2019 Cable Television Laboratories, Inc. All rights reserved."
    ],
    [
      "Revisions",
      [
        [
          "201906130000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-19.2024-1."
          ]
        ],
        [
          "201901240000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1."
          ]
        ],
        [
          "201810180000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2."
          ]
        ],
        [
          "201804120000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
          ]
        ],
        [
          "201708030000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
          ]
        ],
        [
          "201704130000Z",
          [
            "DESCRIPTION",
            "Initial version, created by R-OSSI-N-17.1707-2."
          ]
        ]
      ]
    ]
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-CTRL-MIB-2019-06-13.txt

    Module: DOCS-RPHY-CTRL-MIB

    Published definition
    docsRphyCtrlMib MODULE-IDENTITY 
    LAST-UPDATED    "201906130000Z" -- June 13, 2019
        ORGANIZATION    "Cable Television Laboratories, Inc" 
        CONTACT-INFO 
             "
             Postal: Cable Television Laboratories, Inc. 
             400 Centennial Parkway 
             Louisville, Colorado 80027-1266 
             U.S.A. 
             Phone: +1 303-661-9100 
             Fax: +1 303-661-9199 
             E-mail: mibs@cablelabs.com" 
        DESCRIPTION 
            "This MIB module contains the control management objects for
             the Remote PHY Device (RPD) management.
             Copyright 2017-2019 Cable Television Laboratories, Inc.
             All rights reserved."
             
        REVISION "201906130000Z" -- June 13, 2019
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-19.2024-1."
        REVISION "201901240000Z" -- January 24, 2019
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1."
        REVISION "201810180000Z" -- October 18, 2018
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2."
        REVISION "201804120000Z" -- April 12, 2018
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
        REVISION "201708030000Z" -- August 3, 2017
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
        REVISION "201704130000Z" -- April 13, 2017
        DESCRIPTION 
            "Initial version, created by R-OSSI-N-17.1707-2."
    ::= { clabProjDocsis 31 }
    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-CTRL-MIB-2019-06-13.txt
    Source location: DOCS-RPHY-CTRL-MIB::docsRphyCtrlMib.
    Source version and references

    Downloaded: 2026-10-26T22:49:51.600716+00:00.

docsRphyCtrlMib

Status in source: unspecified.

Names: docsRphyCtrlMib

Technical details
{
  "smi_kind": "MODULE-IDENTITY",
  "definition": [
    "docsRphyCtrlMib",
    "MODULE-IDENTITY",
    "LAST-UPDATED",
    [
      "literal",
      "223230313831303138303030305a22"
    ],
    "ORGANIZATION",
    "\"Cable Television Laboratories, Inc\"",
    "CONTACT-INFO",
    "\" Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com\"",
    "DESCRIPTION",
    "\"This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2018 Cable Television Laboratories, Inc. All rights reserved.\"",
    "REVISION",
    [
      "literal",
      "223230313831303138303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2.\"",
    "REVISION",
    [
      "literal",
      "223230313830343132303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730383033303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730343133303030305a22"
    ],
    "DESCRIPTION",
    "\"Initial version, created by R-OSSI-N-17.1707-2.\"",
    "::=",
    "{",
    "clabProjDocsis",
    "31",
    "}"
  ],
  "syntax_tree": [
    [
      "LAST-UPDATED",
      "201810180000Z"
    ],
    [
      "ORGANIZATION",
      "Cable Television Laboratories, Inc"
    ],
    [
      "CONTACT-INFO",
      "Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com"
    ],
    [
      "DESCRIPTION",
      "This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2018 Cable Television Laboratories, Inc. All rights reserved."
    ],
    [
      "Revisions",
      [
        [
          "201810180000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2."
          ]
        ],
        [
          "201804120000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
          ]
        ],
        [
          "201708030000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
          ]
        ],
        [
          "201704130000Z",
          [
            "DESCRIPTION",
            "Initial version, created by R-OSSI-N-17.1707-2."
          ]
        ]
      ]
    ]
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-CTRL-MIB-2018-10-18.txt

    Module: DOCS-RPHY-CTRL-MIB

    Published definition
    docsRphyCtrlMib MODULE-IDENTITY 
    LAST-UPDATED    "201810180000Z" -- October 18, 2018
        ORGANIZATION    "Cable Television Laboratories, Inc" 
        CONTACT-INFO 
             "
             Postal: Cable Television Laboratories, Inc. 
             400 Centennial Parkway 
             Louisville, Colorado 80027-1266 
             U.S.A. 
             Phone: +1 303-661-9100 
             Fax: +1 303-661-9199 
             E-mail: mibs@cablelabs.com" 
        DESCRIPTION 
            "This MIB module contains the control management objects for
             the Remote PHY Device (RPD) management.
             Copyright 2017-2018 Cable Television Laboratories, Inc.
             All rights reserved."
        	 
        REVISION "201810180000Z" -- October 18, 2018
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2."
        REVISION "201804120000Z" -- April 12, 2018
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
        REVISION "201708030000Z" -- August 3, 2017
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
        REVISION "201704130000Z" -- April 13, 2017
        DESCRIPTION 
            "Initial version, created by R-OSSI-N-17.1707-2."
    ::= { clabProjDocsis 31 }
    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-CTRL-MIB-2018-10-18.txt
    Source location: DOCS-RPHY-CTRL-MIB::docsRphyCtrlMib.
    Source version and references

    Downloaded: 2026-10-26T22:49:51.159131+00:00.

docsRphyCtrlMib

Status in source: unspecified.

Names: docsRphyCtrlMib

Technical details
{
  "smi_kind": "MODULE-IDENTITY",
  "definition": [
    "docsRphyCtrlMib",
    "MODULE-IDENTITY",
    "LAST-UPDATED",
    [
      "literal",
      "223230323230363330303030305a22"
    ],
    "ORGANIZATION",
    "\"Cable Television Laboratories, Inc\"",
    "CONTACT-INFO",
    "\" Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com\"",
    "DESCRIPTION",
    "\"This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2022 Cable Television Laboratories, Inc. All rights reserved.\"",
    "REVISION",
    [
      "literal",
      "2232303232303633303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-22.2262-1.\"",
    "REVISION",
    [
      "literal",
      "223230323131313032313030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-21.2195-1.\"",
    "REVISION",
    [
      "literal",
      "223230323030353231303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-20.2095-1.\"",
    "REVISION",
    [
      "literal",
      "223230313930363133303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-19.2024-1.\"",
    "REVISION",
    [
      "literal",
      "223230313930313234303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1.\"",
    "REVISION",
    [
      "literal",
      "223230313831303138303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2.\"",
    "REVISION",
    [
      "literal",
      "223230313830343132303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730383033303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730343133303030305a22"
    ],
    "DESCRIPTION",
    "\"Initial version, created by R-OSSI-N-17.1707-2.\"",
    "::=",
    "{",
    "clabProjDocsis",
    "31",
    "}"
  ],
  "syntax_tree": [
    [
      "LAST-UPDATED",
      "202206300000Z"
    ],
    [
      "ORGANIZATION",
      "Cable Television Laboratories, Inc"
    ],
    [
      "CONTACT-INFO",
      "Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com"
    ],
    [
      "DESCRIPTION",
      "This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2022 Cable Television Laboratories, Inc. All rights reserved."
    ],
    [
      "Revisions",
      [
        [
          "20220630000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-22.2262-1."
          ]
        ],
        [
          "202111021000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-21.2195-1."
          ]
        ],
        [
          "202005210000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-20.2095-1."
          ]
        ],
        [
          "201906130000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-19.2024-1."
          ]
        ],
        [
          "201901240000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1."
          ]
        ],
        [
          "201810180000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2."
          ]
        ],
        [
          "201804120000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
          ]
        ],
        [
          "201708030000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
          ]
        ],
        [
          "201704130000Z",
          [
            "DESCRIPTION",
            "Initial version, created by R-OSSI-N-17.1707-2."
          ]
        ]
      ]
    ]
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-CTRL-MIB-2022-06-30.txt

    Module: DOCS-RPHY-CTRL-MIB

    Published definition
    docsRphyCtrlMib MODULE-IDENTITY 
    LAST-UPDATED    "202206300000Z" -- June 30, 2022
        ORGANIZATION    "Cable Television Laboratories, Inc" 
        CONTACT-INFO 
             "
             Postal: Cable Television Laboratories, Inc. 
             400 Centennial Parkway 
             Louisville, Colorado 80027-1266 
             U.S.A. 
             Phone: +1 303-661-9100 
             Fax: +1 303-661-9199 
             E-mail: mibs@cablelabs.com" 
        DESCRIPTION 
            "This MIB module contains the control management objects for
             the Remote PHY Device (RPD) management.
             Copyright 2017-2022 Cable Television Laboratories, Inc.
             All rights reserved."
             
        REVISION "20220630000Z" -- June 30, 20222
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-22.2262-1."
        REVISION "202111021000Z" -- October 21, 2021
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-21.2195-1."
        REVISION "202005210000Z" -- May 21, 2020
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-20.2095-1."
        REVISION "201906130000Z" -- June 13, 2019
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-19.2024-1."
        REVISION "201901240000Z" -- January 24, 2019
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1."
        REVISION "201810180000Z" -- October 18, 2018
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2."
        REVISION "201804120000Z" -- April 12, 2018
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
        REVISION "201708030000Z" -- August 3, 2017
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
        REVISION "201704130000Z" -- April 13, 2017
        DESCRIPTION 
            "Initial version, created by R-OSSI-N-17.1707-2."
    ::= { clabProjDocsis 31 }
    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-CTRL-MIB-2022-06-30.txt
    Source location: DOCS-RPHY-CTRL-MIB::docsRphyCtrlMib.
    Source version and references

    Downloaded: 2026-10-26T22:49:52.091637+00:00.

docsRphyCtrlMib

Status in source: unspecified.

Names: docsRphyCtrlMib

Technical details
{
  "smi_kind": "MODULE-IDENTITY",
  "definition": [
    "docsRphyCtrlMib",
    "MODULE-IDENTITY",
    "LAST-UPDATED",
    [
      "literal",
      "223230323030353231303030305a22"
    ],
    "ORGANIZATION",
    "\"Cable Television Laboratories, Inc\"",
    "CONTACT-INFO",
    "\" Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com\"",
    "DESCRIPTION",
    "\"This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2020 Cable Television Laboratories, Inc. All rights reserved.\"",
    "REVISION",
    [
      "literal",
      "223230323030353231303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-20.2095-1.\"",
    "REVISION",
    [
      "literal",
      "223230313930363133303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-19.2024-1.\"",
    "REVISION",
    [
      "literal",
      "223230313930313234303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1.\"",
    "REVISION",
    [
      "literal",
      "223230313831303138303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2.\"",
    "REVISION",
    [
      "literal",
      "223230313830343132303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730383033303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730343133303030305a22"
    ],
    "DESCRIPTION",
    "\"Initial version, created by R-OSSI-N-17.1707-2.\"",
    "::=",
    "{",
    "clabProjDocsis",
    "31",
    "}"
  ],
  "syntax_tree": [
    [
      "LAST-UPDATED",
      "202005210000Z"
    ],
    [
      "ORGANIZATION",
      "Cable Television Laboratories, Inc"
    ],
    [
      "CONTACT-INFO",
      "Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com"
    ],
    [
      "DESCRIPTION",
      "This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2020 Cable Television Laboratories, Inc. All rights reserved."
    ],
    [
      "Revisions",
      [
        [
          "202005210000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-20.2095-1."
          ]
        ],
        [
          "201906130000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-19.2024-1."
          ]
        ],
        [
          "201901240000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1."
          ]
        ],
        [
          "201810180000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2."
          ]
        ],
        [
          "201804120000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
          ]
        ],
        [
          "201708030000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
          ]
        ],
        [
          "201704130000Z",
          [
            "DESCRIPTION",
            "Initial version, created by R-OSSI-N-17.1707-2."
          ]
        ]
      ]
    ]
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-CTRL-MIB-2020-05-21.txt

    Module: DOCS-RPHY-CTRL-MIB

    Published definition
    docsRphyCtrlMib MODULE-IDENTITY 
    LAST-UPDATED    "202005210000Z" -- May 21, 2020
        ORGANIZATION    "Cable Television Laboratories, Inc" 
        CONTACT-INFO 
             "
             Postal: Cable Television Laboratories, Inc. 
             400 Centennial Parkway 
             Louisville, Colorado 80027-1266 
             U.S.A. 
             Phone: +1 303-661-9100 
             Fax: +1 303-661-9199 
             E-mail: mibs@cablelabs.com" 
        DESCRIPTION 
            "This MIB module contains the control management objects for
             the Remote PHY Device (RPD) management.
             Copyright 2017-2020 Cable Television Laboratories, Inc.
             All rights reserved."
             
        REVISION "202005210000Z" -- May 21, 2020
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-20.2095-1."
        REVISION "201906130000Z" -- June 13, 2019
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-19.2024-1."
        REVISION "201901240000Z" -- January 24, 2019
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1."
        REVISION "201810180000Z" -- October 18, 2018
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2."
        REVISION "201804120000Z" -- April 12, 2018
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
        REVISION "201708030000Z" -- August 3, 2017
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
        REVISION "201704130000Z" -- April 13, 2017
        DESCRIPTION 
            "Initial version, created by R-OSSI-N-17.1707-2."
    ::= { clabProjDocsis 31 }
    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-CTRL-MIB-2020-05-21.txt
    Source location: DOCS-RPHY-CTRL-MIB::docsRphyCtrlMib.
    Source version and references

    Downloaded: 2026-10-26T22:49:51.542388+00:00.

docsRphyCtrlMib

Status in source: unspecified.

Names: docsRphyCtrlMib

Technical details
{
  "smi_kind": "MODULE-IDENTITY",
  "definition": [
    "docsRphyCtrlMib",
    "MODULE-IDENTITY",
    "LAST-UPDATED",
    [
      "literal",
      "223230323330393134303030305a22"
    ],
    "ORGANIZATION",
    "\"Cable Television Laboratories, Inc\"",
    "CONTACT-INFO",
    "\" Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com\"",
    "DESCRIPTION",
    "\"This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2023 Cable Television Laboratories, Inc. All rights reserved.\"",
    "REVISION",
    [
      "literal",
      "223230323330393134303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-23.2331-1.\"",
    "REVISION",
    [
      "literal",
      "223230323230363330303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-22.2262-1.\"",
    "REVISION",
    [
      "literal",
      "223230323131303231303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-21.2195-1.\"",
    "REVISION",
    [
      "literal",
      "223230323030353231303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-20.2095-1.\"",
    "REVISION",
    [
      "literal",
      "223230313930363133303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-19.2024-1.\"",
    "REVISION",
    [
      "literal",
      "223230313930313234303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1.\"",
    "REVISION",
    [
      "literal",
      "223230313831303138303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2.\"",
    "REVISION",
    [
      "literal",
      "223230313830343132303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730383033303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730343133303030305a22"
    ],
    "DESCRIPTION",
    "\"Initial version, created by R-OSSI-N-17.1707-2.\"",
    "::=",
    "{",
    "clabProjDocsis",
    "31",
    "}"
  ],
  "syntax_tree": [
    [
      "LAST-UPDATED",
      "202309140000Z"
    ],
    [
      "ORGANIZATION",
      "Cable Television Laboratories, Inc"
    ],
    [
      "CONTACT-INFO",
      "Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com"
    ],
    [
      "DESCRIPTION",
      "This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2023 Cable Television Laboratories, Inc. All rights reserved."
    ],
    [
      "Revisions",
      [
        [
          "202309140000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-23.2331-1."
          ]
        ],
        [
          "202206300000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-22.2262-1."
          ]
        ],
        [
          "202110210000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-21.2195-1."
          ]
        ],
        [
          "202005210000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-20.2095-1."
          ]
        ],
        [
          "201906130000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-19.2024-1."
          ]
        ],
        [
          "201901240000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1."
          ]
        ],
        [
          "201810180000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2."
          ]
        ],
        [
          "201804120000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
          ]
        ],
        [
          "201708030000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
          ]
        ],
        [
          "201704130000Z",
          [
            "DESCRIPTION",
            "Initial version, created by R-OSSI-N-17.1707-2."
          ]
        ]
      ]
    ]
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-CTRL-MIB.mib

    Module: DOCS-RPHY-CTRL-MIB

    Published definition
    docsRphyCtrlMib MODULE-IDENTITY 
    LAST-UPDATED    "202309140000Z" -- September 14, 2023
        ORGANIZATION    "Cable Television Laboratories, Inc" 
        CONTACT-INFO 
             "
             Postal: Cable Television Laboratories, Inc. 
             400 Centennial Parkway 
             Louisville, Colorado 80027-1266 
             U.S.A. 
             Phone: +1 303-661-9100 
             Fax: +1 303-661-9199 
             E-mail: mibs@cablelabs.com" 
        DESCRIPTION 
            "This MIB module contains the control management objects for
             the Remote PHY Device (RPD) management.
             Copyright 2017-2023 Cable Television Laboratories, Inc.
             All rights reserved."
             
        REVISION "202309140000Z" -- September 14, 2023
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-23.2331-1."
        REVISION "202206300000Z" -- June 30, 2022
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-22.2262-1."
        REVISION "202110210000Z" -- October 21, 2021
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-21.2195-1."
        REVISION "202005210000Z" -- May 21, 2020
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-20.2095-1."
        REVISION "201906130000Z" -- June 13, 2019
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-19.2024-1."
        REVISION "201901240000Z" -- January 24, 2019
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1."
        REVISION "201810180000Z" -- October 18, 2018
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2."
        REVISION "201804120000Z" -- April 12, 2018
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
        REVISION "201708030000Z" -- August 3, 2017
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
        REVISION "201704130000Z" -- April 13, 2017
        DESCRIPTION 
            "Initial version, created by R-OSSI-N-17.1707-2."
    ::= { clabProjDocsis 31 }
    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-CTRL-MIB.mib
    Source location: DOCS-RPHY-CTRL-MIB::docsRphyCtrlMib.
    Source version and references

    Downloaded: 2026-10-26T22:47:24.206809+00:00.

docsRphyCtrlMib

Status in source: unspecified.

Names: docsRphyCtrlMib

Technical details
{
  "smi_kind": "MODULE-IDENTITY",
  "definition": [
    "docsRphyCtrlMib",
    "MODULE-IDENTITY",
    "LAST-UPDATED",
    [
      "literal",
      "223230323131303231303030305a22"
    ],
    "ORGANIZATION",
    "\"Cable Television Laboratories, Inc\"",
    "CONTACT-INFO",
    "\" Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com\"",
    "DESCRIPTION",
    "\"This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2021 Cable Television Laboratories, Inc. All rights reserved.\"",
    "REVISION",
    [
      "literal",
      "223230323131303231303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-21.2195-1.\"",
    "REVISION",
    [
      "literal",
      "223230323030353231303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-20.2095-1.\"",
    "REVISION",
    [
      "literal",
      "223230313930363133303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-19.2024-1.\"",
    "REVISION",
    [
      "literal",
      "223230313930313234303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1.\"",
    "REVISION",
    [
      "literal",
      "223230313831303138303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2.\"",
    "REVISION",
    [
      "literal",
      "223230313830343132303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730383033303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730343133303030305a22"
    ],
    "DESCRIPTION",
    "\"Initial version, created by R-OSSI-N-17.1707-2.\"",
    "::=",
    "{",
    "clabProjDocsis",
    "31",
    "}"
  ],
  "syntax_tree": [
    [
      "LAST-UPDATED",
      "202110210000Z"
    ],
    [
      "ORGANIZATION",
      "Cable Television Laboratories, Inc"
    ],
    [
      "CONTACT-INFO",
      "Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com"
    ],
    [
      "DESCRIPTION",
      "This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2021 Cable Television Laboratories, Inc. All rights reserved."
    ],
    [
      "Revisions",
      [
        [
          "202110210000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-21.2195-1."
          ]
        ],
        [
          "202005210000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-20.2095-1."
          ]
        ],
        [
          "201906130000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-19.2024-1."
          ]
        ],
        [
          "201901240000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1."
          ]
        ],
        [
          "201810180000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2."
          ]
        ],
        [
          "201804120000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
          ]
        ],
        [
          "201708030000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
          ]
        ],
        [
          "201704130000Z",
          [
            "DESCRIPTION",
            "Initial version, created by R-OSSI-N-17.1707-2."
          ]
        ]
      ]
    ]
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-CTRL-MIB-2021-10-21.txt

    Module: DOCS-RPHY-CTRL-MIB

    Published definition
    docsRphyCtrlMib MODULE-IDENTITY 
    LAST-UPDATED    "202110210000Z" -- October 21, 2021
        ORGANIZATION    "Cable Television Laboratories, Inc" 
        CONTACT-INFO 
             "
             Postal: Cable Television Laboratories, Inc. 
             400 Centennial Parkway 
             Louisville, Colorado 80027-1266 
             U.S.A. 
             Phone: +1 303-661-9100 
             Fax: +1 303-661-9199 
             E-mail: mibs@cablelabs.com" 
        DESCRIPTION 
            "This MIB module contains the control management objects for
             the Remote PHY Device (RPD) management.
             Copyright 2017-2021 Cable Television Laboratories, Inc.
             All rights reserved."
             
        REVISION "202110210000Z" -- October 21, 2021
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-21.2195-1."
        REVISION "202005210000Z" -- May 21, 2020
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-20.2095-1."
        REVISION "201906130000Z" -- June 13, 2019
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-19.2024-1."
        REVISION "201901240000Z" -- January 24, 2019
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1985-1."
        REVISION "201810180000Z" -- October 18, 2018
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1958-2."
        REVISION "201804120000Z" -- April 12, 2018
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
        REVISION "201708030000Z" -- August 3, 2017
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
        REVISION "201704130000Z" -- April 13, 2017
        DESCRIPTION 
            "Initial version, created by R-OSSI-N-17.1707-2."
    ::= { clabProjDocsis 31 }
    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-CTRL-MIB-2021-10-21.txt
    Source location: DOCS-RPHY-CTRL-MIB::docsRphyCtrlMib.
    Source version and references

    Downloaded: 2026-10-26T22:49:51.765078+00:00.

docsRphyCtrlMib

Status in source: unspecified.

Names: docsRphyCtrlMib

Technical details
{
  "smi_kind": "MODULE-IDENTITY",
  "definition": [
    "docsRphyCtrlMib",
    "MODULE-IDENTITY",
    "LAST-UPDATED",
    [
      "literal",
      "223230313730343133303030305a22"
    ],
    "ORGANIZATION",
    "\"Cable Television Laboratories, Inc\"",
    "CONTACT-INFO",
    "\" Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com\"",
    "DESCRIPTION",
    "\"This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017 Cable Television Laboratories, Inc. All rights reserved.\"",
    "REVISION",
    [
      "literal",
      "223230313730343133303030305a22"
    ],
    "DESCRIPTION",
    "\"Initial version, created by R-OSSI-N-17.1707-2.\"",
    "::=",
    "{",
    "clabProjDocsis",
    "31",
    "}"
  ],
  "syntax_tree": [
    [
      "LAST-UPDATED",
      "201704130000Z"
    ],
    [
      "ORGANIZATION",
      "Cable Television Laboratories, Inc"
    ],
    [
      "CONTACT-INFO",
      "Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com"
    ],
    [
      "DESCRIPTION",
      "This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017 Cable Television Laboratories, Inc. All rights reserved."
    ],
    [
      "Revisions",
      [
        [
          "201704130000Z",
          [
            "DESCRIPTION",
            "Initial version, created by R-OSSI-N-17.1707-2."
          ]
        ]
      ]
    ]
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-CTRL-MIB-2017-04-13.txt

    Module: DOCS-RPHY-CTRL-MIB

    Published definition
    docsRphyCtrlMib MODULE-IDENTITY 
        LAST-UPDATED    "201704130000Z" -- April 13, 2017
        ORGANIZATION    "Cable Television Laboratories, Inc" 
        CONTACT-INFO 
             "
             Postal: Cable Television Laboratories, Inc. 
             400 Centennial Parkway 
             Louisville, Colorado 80027-1266 
             U.S.A. 
             Phone: +1 303-661-9100 
             Fax: +1 303-661-9199 
             E-mail: mibs@cablelabs.com" 
        DESCRIPTION 
            "This MIB module contains the control management objects for
             the Remote PHY Device (RPD) management.
             Copyright 2017 Cable Television Laboratories, Inc.
             All rights reserved."
        REVISION "201704130000Z" -- April 13, 2017
        DESCRIPTION 
            "Initial version, created by R-OSSI-N-17.1707-2."
    ::= { clabProjDocsis 31 }
    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}

    Source data warning: This April 2017 original references clabProjDocsis but omits its IMPORTS entry. The numeric namespace is independently defined in the official CLAB-DEF-MIB, available below. Published assignments and the missing import are preserved.

    · Download DOCS-RPHY-CTRL-MIB-2017-04-13.txt

    Related source files and packages:


    Source location: DOCS-RPHY-CTRL-MIB::docsRphyCtrlMib.
    Source version and references

    Downloaded: 2026-10-26T22:49:50.561502+00:00.

docsRphyCtrlMib

Status in source: unspecified.

Names: docsRphyCtrlMib

Technical details
{
  "smi_kind": "MODULE-IDENTITY",
  "definition": [
    "docsRphyCtrlMib",
    "MODULE-IDENTITY",
    "LAST-UPDATED",
    [
      "literal",
      "223230313830343132303030305a22"
    ],
    "ORGANIZATION",
    "\"Cable Television Laboratories, Inc\"",
    "CONTACT-INFO",
    "\" Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com\"",
    "DESCRIPTION",
    "\"This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2018 Cable Television Laboratories, Inc. All rights reserved.\"",
    "REVISION",
    [
      "literal",
      "223230313830343132303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730383033303030305a22"
    ],
    "DESCRIPTION",
    "\"Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2.\"",
    "REVISION",
    [
      "literal",
      "223230313730343133303030305a22"
    ],
    "DESCRIPTION",
    "\"Initial version, created by R-OSSI-N-17.1707-2.\"",
    "::=",
    "{",
    "clabProjDocsis",
    "31",
    "}"
  ],
  "syntax_tree": [
    [
      "LAST-UPDATED",
      "201804120000Z"
    ],
    [
      "ORGANIZATION",
      "Cable Television Laboratories, Inc"
    ],
    [
      "CONTACT-INFO",
      "Postal: Cable Television Laboratories, Inc. 400 Centennial Parkway Louisville, Colorado 80027-1266 U.S.A. Phone: +1 303-661-9100 Fax: +1 303-661-9199 E-mail: mibs@cablelabs.com"
    ],
    [
      "DESCRIPTION",
      "This MIB module contains the control management objects for the Remote PHY Device (RPD) management. Copyright 2017-2018 Cable Television Laboratories, Inc. All rights reserved."
    ],
    [
      "Revisions",
      [
        [
          "201804120000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
          ]
        ],
        [
          "201708030000Z",
          [
            "DESCRIPTION",
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
          ]
        ],
        [
          "201704130000Z",
          [
            "DESCRIPTION",
            "Initial version, created by R-OSSI-N-17.1707-2."
          ]
        ]
      ]
    ]
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-CTRL-MIB-2018-04-12.txt

    Module: DOCS-RPHY-CTRL-MIB

    Published definition
    docsRphyCtrlMib MODULE-IDENTITY 
    LAST-UPDATED    "201804120000Z" -- April 12, 2018
        ORGANIZATION    "Cable Television Laboratories, Inc" 
        CONTACT-INFO 
             "
             Postal: Cable Television Laboratories, Inc. 
             400 Centennial Parkway 
             Louisville, Colorado 80027-1266 
             U.S.A. 
             Phone: +1 303-661-9100 
             Fax: +1 303-661-9199 
             E-mail: mibs@cablelabs.com" 
        DESCRIPTION 
            "This MIB module contains the control management objects for
             the Remote PHY Device (RPD) management.
             Copyright 2017-2018 Cable Television Laboratories, Inc.
             All rights reserved."
        	 
        REVISION "201804120000Z" -- April 12, 2018
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-18.1893-2."
        REVISION "201708030000Z" -- August 3, 2017
        DESCRIPTION
            "Revised Version includes ECN DOCS-RPHY-CTRL-MIB-N-17.1752-2."
        REVISION "201704130000Z" -- April 13, 2017
        DESCRIPTION 
            "Initial version, created by R-OSSI-N-17.1707-2."
    ::= { clabProjDocsis 31 }
    Module imports
    {'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-RPHY-MIB': ['docsRphyRpdDevInfoUniqueId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-CTRL-MIB-2018-04-12.txt
    Source location: DOCS-RPHY-CTRL-MIB::docsRphyCtrlMib.
    Source version and references

    Downloaded: 2026-10-26T22:49:50.843980+00:00.

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Ralph Brown

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Maria Stachelek

Direct children (3)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4491.2.1.31.0 docsRphyCtrlNotifications00
1.3.6.1.4.1.4491.2.1.31.1 docsRphyCtrlObjects138
1.3.6.1.4.1.4491.2.1.31.2 docsRphyCtrlConformance24

Siblings (37)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4491.2.1.1 dsgMIB00
1.3.6.1.4.1.4491.2.1.2 docsLoadBalMib, docsLoadBalanceMib386 This is the MIB Module for the load balancing.
Load balancing is manageable on a per-CM basis.
Each CM is assigned:
a) to a set of…
1.3.6.1.4.1.4491.2.1.3 dsgIfMIB488 This is the MIB Module for the DOCSIS Set-top Gateway
(DSG). The DSG provides a one-way IP datagram transport
for Out-Of-Band (OO…
1.3.6.1.4.1.4491.2.1.4 dsgIfStdMib382
1.3.6.1.4.1.4491.2.1.5 docsIfExt2Mib341 This MIB module contains the management objects that enhance
DOCSIS 2.0 feature set.
It includes SCDMA capability of limiting the…
1.3.6.1.4.1.4491.2.1.6 docsIfMCmtsMib3163 This MIB module contains the management objects for the
configuration and management of the External PHY interface
(DEPI) of the …
1.3.6.1.4.1.4491.2.1.7 dtiMib380 This MIB module provides the management objects necessary
to configure and manage the DOCSIS Timing Interface
devices.
1.3.6.1.4.1.4491.2.1.8 docsL2vpnMIB383 This is the management MIB for devices complying to the
DOCSIS L2VPN Feature.
1.3.6.1.4.1.4491.2.1.9 docsDiagMib361 This is the MIB Module for the Diagnostic Log for
DOCSIS-compliant Cable Modem Termination Systems (CMTS).

The purpose of the Dia…
1.3.6.1.4.1.4491.2.1.10 docsSubmgt3Mib2100 This MIB module contains the management objects for the
CMTS control of the IP4 and IPv6 traffic with origin and
destination to C…
1.3.6.1.4.1.4491.2.1.11 docsSecMib2179 This MIB module contains the management objects for
the management of the security requirements in the DOCSIS
Security Specificat…
1.3.6.1.4.1.4491.2.1.12 docsTestMIB218 This is the MIB Module supporting programmable test features
for DOCSIS 2.0 compliant Cable Modems (CM) and Cable Modem
Terminati…
1.3.6.1.4.1.4491.2.1.13 sledMib421 This MIB module provides the management objects necessary
to configure and invoke the Software Loopback Application
for eDOCSIS (…
1.3.6.1.4.1.4491.2.1.14 esafeMib, teaPwTcMIB234 esafeMib MODULE-IDENTITY
LAST-UPDATED "200411240000Z" ?- November 24, 2004
ORGANIZATION "CableLabs eDOCSIS Working Group"
CONTA…
1.3.6.1.4.1.4491.2.1.15 teaPwMIB3125 CL-PW-MIB
1.3.6.1.4.1.4491.2.1.16 teaPwTDMMIB3123 CL-PW-TDM-MIB
1.3.6.1.4.1.4491.2.1.17 teaPwTcMIB00
1.3.6.1.4.1.4491.2.1.18 docsMcastMib294 This MIB module contains the management objects for the
management of Multicast over DOCSIS to support Multicast
DSID forwarding …
1.3.6.1.4.1.4491.2.1.19 docsMcastAuthMib254 This MIB module contains the management objects for the
management of the CMTS Multicast Authorization Module.
Copyright 1999-200…
1.3.6.1.4.1.4491.2.1.20 docsIf3Mib3295 This MIB module contains the management objects for the
management of DOCSIS 3.0 features, primarly channel bonding,
interface to…
1.3.6.1.4.1.4491.2.1.21 docsQos3Mib, docsQosMib3486 This MIB module contains the management objects for the
management of QOS for channel bonding.
1.3.6.1.4.1.4491.2.1.22 docsLoadbal3Mib2118 This MIB module contains the management objects
for the DOCSIS 3.0 CMTS Load Balanding operation.
Copyright 1999-2006 Cable Telev…
1.3.6.1.4.1.4491.2.1.23 docsDrfMib342 This MIB module contains the management objects for the
management of the Downstream RF Interface specification.
Copyright 1999-2…
1.3.6.1.4.1.4491.2.1.24 ccapMib342
1.3.6.1.4.1.4491.2.1.27 docsPnmMIB3390
1.3.6.1.4.1.4491.2.1.28 docsIf31Mib3381
1.3.6.1.4.1.4491.2.1.29 docsBpi2Ext31Mib330
1.3.6.1.4.1.4491.2.1.30 docsRphyMib4952
1.3.6.1.4.1.4491.2.1.32 docsRphyPtpMib3142
1.3.6.1.4.1.4491.2.1.33 docsRphyStatsMib3167
1.3.6.1.4.1.4491.2.1.34 docsRphySecMib338
1.3.6.1.4.1.4491.2.1.35 docsFdxMib571
1.3.6.1.4.1.4491.2.1.36 docsFmaLiMib370
1.3.6.1.4.1.4491.2.1.37 docsLeakDetectMib335
1.3.6.1.4.1.4491.2.1.38 docsIf40Mib317
1.3.6.1.4.1.4491.2.1.39 docsFddMib227
1.3.6.1.4.1.4491.2.1.1317 sledMib421 sledMib MODULE-IDENTITY
LAST-UPDATED "200411240000Z" -- November 24, 2004
ORGANIZATION "CableLabs eDOCSIS Working Group"
CONTAC…