Configured OSPF graceful restart timeout interval. This object is persistent, and when written, the entity SHOULD save the change to non-volatile storage.
Sources for this description
NETGEAR MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4526.17.216.2.1.17
Configured OSPF graceful restart timeout interval. This object is persistent, and when written, the entity SHOULD save the change to non-volatile storage.
Identification
{1 3 6 1 4 1 4526 17 216 2 1 17}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rlOspfv3RestartInterval OBJECT-TYPE
SYNTAX Ospfv3UpToRefreshIntervalTC
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured OSPF graceful restart timeout interval.
This object is persistent, and when written, the
entity SHOULD save the change to non-volatile
storage."
REFERENCE "Graceful OSPF Restart, Appendix B.1, Global
Parameters (Minimum subset)"
DEFVAL { 120 }
::= { rlOspfv3GeneralGroupEntry 17 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Configured OSPF graceful restart timeout interval. This object is persistent, and when written, the entity SHOULD save the change to non-volatile storage.
NETGEAR MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: rlOspfv3RestartInterval
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rlOspfv3RestartInterval",
"OBJECT-TYPE",
"SYNTAX",
"Ospfv3UpToRefreshIntervalTC",
"UNITS",
[
"literal",
"227365636f6e647322"
],
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Configured OSPF graceful restart timeout interval. This object is persistent, and when written, the entity SHOULD save the change to non-volatile storage.\"",
"REFERENCE",
"\"Graceful OSPF Restart, Appendix B.1, Global Parameters (Minimum subset)\"",
"DEFVAL",
"{",
"120",
"}",
"::=",
"{",
"rlOspfv3GeneralGroupEntry",
"17",
"}"
],
"syntax_tree": [
[
"row",
"Ospfv3UpToRefreshIntervalTC"
],
[
"UNITS",
"seconds"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Configured OSPF graceful restart timeout interval. This object is persistent, and when written, the entity SHOULD save the change to non-volatile storage."
],
[
"REFERENCE",
"Graceful OSPF Restart, Appendix B.1, Global Parameters (Minimum subset)"
],
null,
null,
[
"DEFVAL",
120
]
]
}Vendor MIB copy from the Observium Community archive. NETGEAR support.
Module: NETGEAR-RADLAN-OSPFV3-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'OSPF-MIB': ['AreaID', 'RouterID', 'Metric', 'BigMetric', 'Status', 'PositiveInteger', 'UpToMaxAge', 'TOSType', 'OspfAuthenticationType', 'HelloRange', 'DesignatedRouterPriority'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'TimeStamp', 'DisplayString'], 'OSPFV3-MIB': ['Ospfv3UpToRefreshIntervalTC', 'Ospfv3DeadIntervalRangeTC', 'Ospfv3RouterIdTC', 'Ospfv3LsIdTC', 'Ospfv3AreaIdTC', 'Ospfv3IfInstIdTC', 'Ospfv3LsaSequenceTC', 'Ospfv3LsaAgeTC'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'mib-2', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'IpAddress'], 'RFC1213-MIB': ['mib-2'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressPrefixLength', 'InetAddressIPv6'], 'NETGEAR-RADLAN-MIB': ['rnd'], 'NETGEAR-RADLAN-OSPF-MIB': ['RlOspfProcessID', 'RlOspfFastHelloMultiplierRange', 'RlOspfRestartHelperStatus', 'RlOspfRestartExitReason', 'RlOspfRouterIdType']}Related source files and packages:
Registration