Description 1
Sources for this description
MIBdepot
Parsed from LIEBERT_GP_PDU.MIB.txt · liebert · LIEBERT-GP-PDU-MIB
Source file: Download LIEBERT_GP_PDU.MIB.txt
OID reference
1.3.6.1.4.1.476.1.42.3.8.30.20.1.5
This is the index that indicates the row of the 'lgpPduTable'
Identification
{1 3 6 1 4 1 476 1 42 3 8 30 20 1 5}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: lgpPduEntryIndex, lgpPduPsEntryIndex.
A query example is omitted because the source variants do not establish compatible read access.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
lgpPduPsEntryIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a unique identifier for the Power Source within a
given PDU. This is one of two indexes used to indicate the row of
the 'lgpPduTable'."
::= { lgpPduPsEntry 5 }lgpPduPsEntryIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a unique identifier for the Power Source within a
given PDU. This is one of two indexes used to indicate the row of
the 'lgpPduTable'."
::= { lgpPduPsEntry 5 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Parsed from LIEBERT_GP_PDU.MIB.txt · liebert · LIEBERT-GP-PDU-MIB
Source file: Download LIEBERT_GP_PDU.MIB.txt
Description 2
This is a unique identifier for the Power Source within a given PDU. This is one of two indexes used to indicate the row of the 'lgpPduTable'.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: lgpPduPsEntryIndex
Vendor MIB copy from the LibreNMS archive.
Module: LIEBERT-GP-PDU-MIB
See published definition above
· Download LIEBERT-GP-PDU-MIBRelated source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: LIEBERT-GP-PDU-MIB
See published definition above
· Download LIEBERT-GP-PDU-MIBHistorical records
lgpPduPsEntryIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the index that indicates the row of the 'lgpPduTable'"
::= { lgpPduPsEntry 5 }
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.10 | lgpPduPsEntryId | 0 | 0 | This is a unique entry id representing a given PDU power source for the PDU. |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.15 | lgpPduPsEntrySysAssignLabel | 0 | 0 | System assigned identifier for this power source. The value is independent of any user assigned label or tag. The exact format o… |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.20 | lgpPduPsEntryModel | 0 | 0 | This is the model name (identifier) of the power supply. |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.25 | lgpPduPsEntryWiringType | 0 | 0 | The PDU's power supply physical wiring type. not-specified The type has not been specified/configured. The end_user must configur… |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.30 | lgpPduPsEntryEpInputRated | 0 | 0 | Rated Input Line Voltage for the power source (i.e. this is the nominal line input voltage; it is NOT a measured voltage). The va… |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.35 | lgpPduPsEntryEcInputRated | 0 | 0 | This is the rated input line current for the module (it is NOT the measured current). |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.40 | lgpPduPsEntryFreqRated | 0 | 0 | Rated input line frequency for this power source (i.e. This is the expected line frequency; it is NOT a measured frequency; it is… |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.50 | lgpPduPsEntryEnergyAccum | 0 | 0 | Total accumulated energy, measured at the power source input, since the last energy reset. Writing a value of 0 (zero) to this ca… |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.55 | lgpPduPsEntrySerialNum | 0 | 0 | This is a unique serial number of the power supply. This number is assigned to the power supply at the time of manufacture. |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.60 | lgpPduPsEntryFirmwareVersion | 0 | 0 | This is the version of the firmware installed on the PDU's power supply. |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.65 | lgpPduPsEntryPwrTotal | 0 | 0 | Total input power for this power supply. This is the sum of the power for all phases |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.70 | lgpPduPsEntryEcNeutral | 0 | 0 | |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.75 | lgpPduPsEntryEcNeutralThrshldOvrWarn | 0 | 0 | |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.80 | lgpPduPsEntryEcNeutralThrshldOvrAlarm | 0 | 0 | |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.85 | lgpPduPsEntryUnbalancedLoadThrshldAlarm | 0 | 0 | |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.90 | lgpPduPsEntryApTotal | 0 | 0 | |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.95 | lgpPduPsEntryPfTotal | 0 | 0 | |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.100 | lgpPduPsEntryEcResidual | 0 | 0 | |
| 1.3.6.1.4.1.476.1.42.3.8.30.20.1.105 | lgpPduPsEntryEcResidualThrshldOvrAlarm | 0 | 0 |