Type of CAM fault trigging the trap.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4998.1.1.10.1.0.40.1
Type of CAM fault trigging the trap.
Identification
{1 3 6 1 4 1 4998 1 1 10 1 0 40 1}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
cerCamFaultId OBJECT-TYPE
SYNTAX CerCamFaultTrapType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Type of CAM fault trigging the trap."
::= { cerCamFaultInfo 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Type of CAM fault trigging the trap.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: cerCamFaultId
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cerCamFaultId",
"OBJECT-TYPE",
"SYNTAX",
"CerCamFaultTrapType",
"MAX-ACCESS",
"accessible-for-notify",
"STATUS",
"current",
"DESCRIPTION",
"\"Type of CAM fault trigging the trap.\"",
"::=",
"{",
"cerCamFaultInfo",
"1",
"}"
],
"syntax_tree": [
[
"row",
"CerCamFaultTrapType"
],
null,
[
"MaxAccessPart",
"accessible-for-notify"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Type of CAM fault trigging the trap."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: CADANT-CMTS-EQUIPMENT-MIB
See published definition above
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex'], 'CADANT-TC': ['AdminState', 'CardId', 'CerCardSubType', 'CerCardType', 'DiskVolumeUsageLevel', 'DuplexStatus', 'EqActionType', 'FirmwareSource', 'FlowControlMode', 'PicType', 'CerPicType', 'PortId', 'PortMode', 'PortDetectedMode', 'PortType', 'CerPortType', 'PrimaryState', 'SecondaryState'], 'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'MacAddress', 'RowStatus', 'TEXTUAL-CONVENTION', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['Counter32', 'Integer32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'TimeTicks', 'IpAddress', 'Unsigned32'], 'DOCS-IF-MIB': ['TenthdBmV'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'CADANT-PRODUCTS-MIB': ['cadEquipment']}Related source files and packages:
Same file in Observium Community.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4998.1.1.10.1.0.40.2 | cerCamFaultRecovery | 0 | 0 | |
| 1.3.6.1.4.1.4998.1.1.10.1.0.40.3 | cerCamFaultAutoFailback | 0 | 0 | |
| 1.3.6.1.4.1.4998.1.1.10.1.0.40.4 | cerCamFaultErrorStr | 0 | 0 |