The value of sysUpTime at the time any of the objects in cardTable last changed.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4998.1.1.10.1.3.2
The value of sysUpTime at the time any of the objects in cardTable last changed.
Identification
{1 3 6 1 4 1 4998 1 1 10 1 3 2}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
cardLastChangeTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time any of the objects
in cardTable last changed. "
::= { equipmentState 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The value of sysUpTime at the time any of the objects in cardTable last changed.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: cardLastChangeTime
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cardLastChangeTime",
"OBJECT-TYPE",
"SYNTAX",
"TimeStamp",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of sysUpTime at the time any of the objects in cardTable last changed. \"",
"::=",
"{",
"equipmentState",
"2",
"}"
],
"syntax_tree": [
[
"row",
"TimeStamp"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of sysUpTime at the time any of the objects in cardTable last changed."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: CADANT-CMTS-EQUIPMENT-MIB
See published definition above
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex'], 'CADANT-TC': ['AdminState', 'CardId', 'CerCardSubType', 'CerCardType', 'DiskVolumeUsageLevel', 'DuplexStatus', 'EqActionType', 'FirmwareSource', 'FlowControlMode', 'PicType', 'CerPicType', 'PortId', 'PortMode', 'PortDetectedMode', 'PortType', 'CerPortType', 'PrimaryState', 'SecondaryState'], 'SNMPv2-TC': ['DateAndTime', 'DisplayString', 'MacAddress', 'RowStatus', 'TEXTUAL-CONVENTION', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['Counter32', 'Integer32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'TimeTicks', 'IpAddress', 'Unsigned32'], 'DOCS-IF-MIB': ['TenthdBmV'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'CADANT-PRODUCTS-MIB': ['cadEquipment']}Related source files and packages:
Same file in Observium Community.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4998.1.1.10.1.3.3 | portLastChangeTime | 0 | 0 |