Time between transmission of UCD messages. (ref 6.3.3)
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.4998.1.1.5.1.1.2
Time between transmission of UCD messages. (ref 6.3.3)
Identification
{1 3 6 1 4 1 4998 1 1 5 1 1 2}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.4998.1.1.5.1.1.2.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
cadSysUCDInterval OBJECT-TYPE
SYNTAX Integer32 (0..2000)
UNITS "Milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time between transmission of UCD messages. (ref 6.3.3)"
::= { cadSysParams 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Time between transmission of UCD messages. (ref 6.3.3)
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: cadSysUCDInterval
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cadSysUCDInterval",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"2000",
")",
"UNITS",
[
"literal",
"224d696c6c697365636f6e647322"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Time between transmission of UCD messages. (ref 6.3.3)\"",
"::=",
"{",
"cadSysParams",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
2000
]
]
]
],
[
"UNITS",
"Milliseconds"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Time between transmission of UCD messages. (ref 6.3.3)"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: CADANT-CMTS-SYSTEM-MIB
See published definition above
{'IF-MIB': ['InterfaceIndexOrZero'], 'CADANT-TC': ['CardId', 'AdminState', 'ServerType', 'OverloadThreshold', 'AdminSrcAddrType'], 'SNMPv2-TC': ['TruthValue', 'DisplayString', 'MacAddress', 'DateAndTime', 'RowStatus'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'Counter32', 'Integer32', 'IpAddress', 'Unsigned32'], 'DOCS-IF-MIB': ['TenthdB'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'DOCS-QOS3-MIB': ['BitRate'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetAddressIPv4', 'InetAddressIPv6'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID'], 'CADANT-PRODUCTS-MIB': ['cadSystem']}Related source files and packages: