Reference record for OID 1.3.6.1.4.1.53973.1.1.1.1.8.3

Parent
1.3.6.1.4.1.53973.1.1.1.1.8 (upsControl)
Node code
3
Node name
upsStartupAfterDelay
Numeric OID
1.3.6.1.4.1.53973.1.1.1.1.8.3
URN notation
urn:oid:1.3.6.1.4.1.53973.1.1.1.1.8.3
ASN.1 notation

{1 3 6 1 4 1 53973 1 1 1 1 8 3}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsStartupAfterDelay(3)}
OID-IRI notation
  • /1/3/6/1/4/1/53973/1/1/1/1/8/3
  • /ISO/Identified-Organization/6/1/4/1/53973/1/1/1/1/8/3
  • /ISO/3/6/1/4/1/53973/1/1/1/1/8/3
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay
  • /iso/identified-organization/dod/internet/private/enterprises/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay
  • /iso/identified-organization/dod/internet/private/vendor-objects/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay
  • /iso/org/dod/internet/private/enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay
  • /iso/org/dod/internet/private/enterprises/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay
  • /iso/org/dod/internet/private/ldap-enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay
  • /iso/org/dod/internet/private/vendor-objects/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay
  • /iso/iso-identified-organization/dod/internet/private/enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay
  • /iso/iso-identified-organization/dod/internet/private/enterprises/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay
  • /iso/iso-organization/dod/internet/private/enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay
  • /iso/iso-organization/dod/internet/private/enterprises/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay
  • /iso/iso-organization/dod/internet/private/vendor-objects/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsStartupAfterDelay

Descriptions

upsStartupAfterDelay — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any upsStartupAfterDelay countdown or upsRebootWithDuration countdown in progress. When read, upsStartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.

Source records

upsStartupAfterDelay

Status in source: current.

Names: upsStartupAfterDelay

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "upsStartupAfterDelay",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "1",
    ".",
    ".",
    "2147483647",
    ")",
    "UNITS",
    [
      "literal",
      "227365636f6e647322"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any upsStartupAfterDelay countdown or upsRebootWithDuration countdown in progress. When read, upsStartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.\"",
    "::=",
    "{",
    "upsControl",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -1,
            2147483647
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "seconds"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the output is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any upsStartupAfterDelay countdown or upsRebootWithDuration countdown in progress. When read, upsStartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. If the countdown expires during a utility failure, the startup shall not occur until the utility power is restored. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted."
    ],
    null,
    null,
    null,
    null
  ]
}
  • Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community) · Publisher's source file: ABBMODULARUPS-MIB

    Vendor MIB copy from the LibreNMS archive.

    Module: ABBMODULARUPS-MIB

    Published definition
    upsStartupAfterDelay OBJECT-TYPE
           SYNTAX     Integer32 (-1..2147483647)
           UNITS      "seconds"
           MAX-ACCESS read-only
           STATUS     current
           DESCRIPTION
                   "Setting this object will start the output after the
                   indicated number of seconds, including starting the
                   UPS, if necessary.  Setting this object to 0 will
                   cause the startup to occur immediately.  Setting this
                   object to -1 will abort the countdown.  If the output
                   is already on at the time the countdown reaches 0,
                   then nothing will happen.  Sets to this object
                   override the effect of any upsStartupAfterDelay
                   countdown or upsRebootWithDuration countdown in
                   progress.  When read, upsStartupAfterDelay will return
                   the number of seconds until startup, or -1 if no
                   startup countdown is in effect.  If the countdown
                   expires during a utility failure, the startup shall
                   not occur until the utility power is restored.  On
                   some systems, if the agent is restarted while a
                   startup countdown is in effect, the countdown is
                   aborted."
           ::= { upsControl 3 }
    Module imports
    {'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}

    Related source files and packages:


    Source location: ABBMODULARUPS-MIB::upsStartupAfterDelay.
    Source version and references

    Downloaded: 2026-10-24T02:14:13.121331+00:00.

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.53973)

ABB Power Protection SA

Siblings (3)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.53973.1.1.1.1.8.1 upsShutdownType00
1.3.6.1.4.1.53973.1.1.1.1.8.2 upsShutdownAfterDelay00
1.3.6.1.4.1.53973.1.1.1.1.8.4 upsRebootWithDuration00