Reference record for OID 1.3.6.1.4.1.53973.1.1.1.1.8.4

Parent
1.3.6.1.4.1.53973.1.1.1.1.8 (upsControl)
Node code
4
Node name
upsRebootWithDuration
Numeric OID
1.3.6.1.4.1.53973.1.1.1.1.8.4
URN notation
urn:oid:1.3.6.1.4.1.53973.1.1.1.1.8.4
ASN.1 notation

{1 3 6 1 4 1 53973 1 1 1 1 8 4}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) abb(53973) ups(1) upsModular(1) upsSystem(1) upsObjects(1) upsControl(8) upsRebootWithDuration(4)}
OID-IRI notation
  • /1/3/6/1/4/1/53973/1/1/1/1/8/4
  • /ISO/Identified-Organization/6/1/4/1/53973/1/1/1/1/8/4
  • /ISO/3/6/1/4/1/53973/1/1/1/1/8/4
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration
  • /iso/identified-organization/dod/internet/private/enterprises/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration
  • /iso/identified-organization/dod/internet/private/vendor-objects/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration
  • /iso/org/dod/internet/private/enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration
  • /iso/org/dod/internet/private/enterprises/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration
  • /iso/org/dod/internet/private/ldap-enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration
  • /iso/org/dod/internet/private/vendor-objects/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration
  • /iso/iso-identified-organization/dod/internet/private/enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration
  • /iso/iso-identified-organization/dod/internet/private/enterprises/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration
  • /iso/iso-organization/dod/internet/private/enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration
  • /iso/iso-organization/dod/internet/private/enterprises/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration
  • /iso/iso-organization/dod/internet/private/vendor-objects/abb/ups/upsModular/upsSystem/upsObjects/upsControl/upsRebootWithDuration

Descriptions

upsRebootWithDuration — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, upsRebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.

Source records

upsRebootWithDuration

Status in source: current.

Names: upsRebootWithDuration

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "upsRebootWithDuration",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "1",
    ".",
    ".",
    "300",
    ")",
    "UNITS",
    [
      "literal",
      "227365636f6e647322"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, upsRebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored.\"",
    "::=",
    "{",
    "upsControl",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -1,
            300
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "seconds"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary. If the number of seconds required to perform the request is greater than the requested duration, then the requested shutdown and startup cycle shall be performed in the minimum time possible, but in no case shall this require more than the requested duration plus 60 seconds. When read, upsRebootWithDuration shall return the number of seconds remaining in the countdown, or -1 if no countdown is in progress. If the startup should occur during a utility failure, the startup shall not occur until the utility power is restored."
    ],
    null,
    null,
    null,
    null
  ]
}
  • Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community) · Publisher's source file: ABBMODULARUPS-MIB

    Vendor MIB copy from the LibreNMS archive.

    Module: ABBMODULARUPS-MIB

    Published definition
    upsRebootWithDuration OBJECT-TYPE
           SYNTAX     Integer32 (-1..300)
           UNITS      "seconds"
           MAX-ACCESS read-only
           STATUS     current
           DESCRIPTION
                   "Setting this object will immediately shutdown (i.e.,
                   turn off) either the UPS output or the UPS system (as
                   determined by the value of upsShutdownType at the time
                   of shutdown) for a period equal to the indicated
                   number of seconds, after which time the output will be
                   started, including starting the UPS, if necessary.  If
                   the number of seconds required to perform the request
                   is greater than the requested duration, then the
                   requested shutdown and startup cycle shall be
                   performed in the minimum time possible, but in no case
                   shall this require more than the requested duration
                   plus 60 seconds.  When read, upsRebootWithDuration
                   shall return the number of seconds remaining in the
                   countdown, or -1 if no countdown is in progress.  If
                   the startup should occur during a utility failure, the
                   startup shall not occur until the utility power is
                   restored."
           ::= { upsControl 4 }
    Module imports
    {'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}

    Related source files and packages:


    Source location: ABBMODULARUPS-MIB::upsRebootWithDuration.
    Source version and references

    Downloaded: 2026-10-24T02:14:13.121331+00:00.

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.53973)

ABB Power Protection SA

Siblings (3)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.53973.1.1.1.1.8.1 upsShutdownType00
1.3.6.1.4.1.53973.1.1.1.1.8.2 upsShutdownAfterDelay00
1.3.6.1.4.1.53973.1.1.1.1.8.3 upsStartupAfterDelay00