ups13BasicCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support full-featured functions, such as control.
{1 3 6 1 4 1 53973 1 1 14 3 1 2}
The compliance statement for UPSs that support full-featured functions, such as control.
Status in source: current.
Names: ups13BasicCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups13BasicCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support full-featured functions, such as control.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups13BasicIdentGroup",
",",
"ups13BasicBatteryGroup",
",",
"ups13BasicInputGroup",
",",
"ups13BasicOutputGroup",
",",
"ups13BasicAlarmGroup",
",",
"ups13BasicTestGroup",
",",
"ups13BasicControlGroup",
"}",
"OBJECT",
"ups13AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups13AlarmOnBattery, ups13AlarmLowBattery, ups13AlarmDepletedBattery, ups13AlarmTempBad, ups13AlarmInputBad, ups13AlarmOutputOverload, ups13AlarmOnBypass, ups13AlarmBypassBad, ups13AlarmOutputOffAsRequested, ups13AlarmUpsOffAsRequested, ups13AlarmUpsOutputOff, ups13AlarmUpsSystemOff, ups13AlarmGeneralFault, ups13AlarmDiagnosticTestFailed, ups13AlarmCommunicationsLost, ups13AlarmShutdownPending, and ups13AlarmTestInProgress.\"",
"OBJECT",
"ups13TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. If no tests are supported, then the only well known test type which must be supported is ups13TestNoTestsInitiated.\"",
"OBJECT",
"ups13OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups13BasicBypassGroup",
"DESCRIPTION",
"\"The ups13BasicBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups13ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups13Compliances",
"2",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support full-featured functions, such as control."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups13BasicIdentGroup",
"ups13BasicBatteryGroup",
"ups13BasicInputGroup",
"ups13BasicOutputGroup",
"ups13BasicAlarmGroup",
"ups13BasicTestGroup",
"ups13BasicControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups13BasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
full-featured functions, such as control."
MODULE -- this module
MANDATORY-GROUPS { ups13BasicIdentGroup,
ups13BasicBatteryGroup, ups13BasicInputGroup,
ups13BasicOutputGroup, ups13BasicAlarmGroup,
ups13BasicTestGroup, ups13BasicControlGroup }
OBJECT ups13AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups13AlarmOnBattery, ups13AlarmLowBattery,
ups13AlarmDepletedBattery, ups13AlarmTempBad,
ups13AlarmInputBad, ups13AlarmOutputOverload,
ups13AlarmOnBypass, ups13AlarmBypassBad,
ups13AlarmOutputOffAsRequested,
ups13AlarmUpsOffAsRequested, ups13AlarmUpsOutputOff,
ups13AlarmUpsSystemOff, ups13AlarmGeneralFault,
ups13AlarmDiagnosticTestFailed,
ups13AlarmCommunicationsLost, ups13AlarmShutdownPending,
and ups13AlarmTestInProgress."
OBJECT ups13TestId
DESCRIPTION
"Support of all `well known' test types is not
required. If no tests are supported, then the only
well known test type which must be supported is
ups13TestNoTestsInitiated."
OBJECT ups13OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups13BasicBypassGroup
DESCRIPTION
"The ups13BasicBypassGroup is only required for UPSs
that have a Bypass present."
OBJECT ups13ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups13Compliances 2 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T02:14:13.121331+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.53973.1.1.14.3.1.1 | ups13SubsetCompliance | 0 | 0 | |
| 1.3.6.1.4.1.53973.1.1.14.3.1.3 | ups13FullCompliance | 0 | 0 |