ups13FullCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support advanced full-featured functions.
{1 3 6 1 4 1 53973 1 1 14 3 1 3}
The compliance statement for UPSs that support advanced full-featured functions.
Status in source: current.
Names: ups13FullCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups13FullCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support advanced full-featured functions.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups13FullIdentGroup",
",",
"ups13FullBatteryGroup",
",",
"ups13FullInputGroup",
",",
"ups13FullOutputGroup",
",",
"ups13FullAlarmGroup",
",",
"ups13FullTestGroup",
",",
"ups13FullControlGroup",
"}",
"OBJECT",
"ups13AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups13AlarmBatteryBad, ups13AlarmOnBattery, ups13AlarmLowBattery, ups13AlarmDepletedBattery, ups13AlarmTempBad, ups13AlarmInputBad, ups13AlarmOnBypass, ups13AlarmBypassBad, ups13AlarmOutputOffAsRequested, ups13AlarmUpsOffAsRequested, ups13AlarmUpsOutputOff, ups13AlarmUpsSystemOff, ups13AlarmGeneralFault, ups13AlarmDiagnosticTestFailed, ups13AlarmCommunicationsLost, ups13AlarmShutdownPending, and ups13AlarmTestInProgress.\"",
"OBJECT",
"ups13TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. The well known test types which must be supported are: ups13TestNoTestsInitiated, ups13TestGeneralSystemsTest, and ups13TestQuickBatteryTest.\"",
"OBJECT",
"ups13OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups13FullBypassGroup",
"DESCRIPTION",
"\"The ups13FullBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups13ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups13Compliances",
"3",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support advanced full-featured functions."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups13FullIdentGroup",
"ups13FullBatteryGroup",
"ups13FullInputGroup",
"ups13FullOutputGroup",
"ups13FullAlarmGroup",
"ups13FullTestGroup",
"ups13FullControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups13FullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
advanced full-featured functions."
MODULE -- this module
MANDATORY-GROUPS { ups13FullIdentGroup, ups13FullBatteryGroup,
ups13FullInputGroup, ups13FullOutputGroup,
ups13FullAlarmGroup, ups13FullTestGroup,
ups13FullControlGroup }
OBJECT ups13AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups13AlarmBatteryBad, ups13AlarmOnBattery,
ups13AlarmLowBattery, ups13AlarmDepletedBattery,
ups13AlarmTempBad, ups13AlarmInputBad, ups13AlarmOnBypass,
ups13AlarmBypassBad, ups13AlarmOutputOffAsRequested,
ups13AlarmUpsOffAsRequested, ups13AlarmUpsOutputOff,
ups13AlarmUpsSystemOff, ups13AlarmGeneralFault,
ups13AlarmDiagnosticTestFailed,
ups13AlarmCommunicationsLost, ups13AlarmShutdownPending,
and ups13AlarmTestInProgress."
OBJECT ups13TestId
DESCRIPTION
"Support of all `well known' test types is not
required. The well known test types which must be
supported are: ups13TestNoTestsInitiated,
ups13TestGeneralSystemsTest, and
ups13TestQuickBatteryTest."
OBJECT ups13OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups13FullBypassGroup
DESCRIPTION
"The ups13FullBypassGroup is only required for UPSs that
have a Bypass present."
OBJECT ups13ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups13Compliances 3 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages: