ups17SubsetCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that only support the two-contact communication protocol.
{1 3 6 1 4 1 53973 1 1 18 3 1 1}
The compliance statement for UPSs that only support the two-contact communication protocol.
Status in source: current.
Names: ups17SubsetCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups17SubsetCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that only support the two-contact communication protocol.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups17SubsetIdentGroup",
",",
"ups17SubsetBatteryGroup",
",",
"ups17SubsetInputGroup",
",",
"ups17SubsetOutputGroup",
",",
"ups17SubsetAlarmGroup",
",",
"ups17SubsetControlGroup",
"}",
"OBJECT",
"ups17BatteryStatus",
"SYNTAX",
"INTEGER",
"{",
"batteryNormal",
"(",
"2",
")",
",",
"batteryLow",
"(",
"3",
")",
"}",
"DESCRIPTION",
"\"Support of the values unknown(1) and batteryDepleted(4) is not required.\"",
"OBJECT",
"ups17AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups17AlarmOnBattery, ups17AlarmLowBattery, ups17AlarmInputBad, ups17AlarmUpsOutputOff, ups17AlarmUpsSystemOff, and ups17AlarmTestInProgress.\"",
"OBJECT",
"ups17OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"3",
")",
",",
"battery",
"(",
"5",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"OBJECT",
"ups17ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups17Compliances",
"1",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that only support the two-contact communication protocol."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups17SubsetIdentGroup",
"ups17SubsetBatteryGroup",
"ups17SubsetInputGroup",
"ups17SubsetOutputGroup",
"ups17SubsetAlarmGroup",
"ups17SubsetControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups17SubsetCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that only support
the two-contact communication protocol."
MODULE -- this module
MANDATORY-GROUPS { ups17SubsetIdentGroup,
ups17SubsetBatteryGroup, ups17SubsetInputGroup,
ups17SubsetOutputGroup, ups17SubsetAlarmGroup,
ups17SubsetControlGroup }
OBJECT ups17BatteryStatus
SYNTAX INTEGER {
batteryNormal(2),
batteryLow(3)
}
DESCRIPTION
"Support of the values unknown(1) and
batteryDepleted(4) is not required."
OBJECT ups17AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups17AlarmOnBattery, ups17AlarmLowBattery,
ups17AlarmInputBad, ups17AlarmUpsOutputOff,
ups17AlarmUpsSystemOff, and ups17AlarmTestInProgress."
OBJECT ups17OutputSource
SYNTAX INTEGER {
normal(3),
battery(5)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
OBJECT ups17ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups17Compliances 1 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T02:14:13.121331+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.53973.1.1.18.3.1.2 | ups17BasicCompliance | 0 | 0 | |
| 1.3.6.1.4.1.53973.1.1.18.3.1.3 | ups17FullCompliance | 0 | 0 |