ups17BasicCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support full-featured functions, such as control.
{1 3 6 1 4 1 53973 1 1 18 3 1 2}
The compliance statement for UPSs that support full-featured functions, such as control.
Status in source: current.
Names: ups17BasicCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups17BasicCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support full-featured functions, such as control.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups17BasicIdentGroup",
",",
"ups17BasicBatteryGroup",
",",
"ups17BasicInputGroup",
",",
"ups17BasicOutputGroup",
",",
"ups17BasicAlarmGroup",
",",
"ups17BasicTestGroup",
",",
"ups17BasicControlGroup",
"}",
"OBJECT",
"ups17AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups17AlarmOnBattery, ups17AlarmLowBattery, ups17AlarmDepletedBattery, ups17AlarmTempBad, ups17AlarmInputBad, ups17AlarmOutputOverload, ups17AlarmOnBypass, ups17AlarmBypassBad, ups17AlarmOutputOffAsRequested, ups17AlarmUpsOffAsRequested, ups17AlarmUpsOutputOff, ups17AlarmUpsSystemOff, ups17AlarmGeneralFault, ups17AlarmDiagnosticTestFailed, ups17AlarmCommunicationsLost, ups17AlarmShutdownPending, and ups17AlarmTestInProgress.\"",
"OBJECT",
"ups17TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. If no tests are supported, then the only well known test type which must be supported is ups17TestNoTestsInitiated.\"",
"OBJECT",
"ups17OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups17BasicBypassGroup",
"DESCRIPTION",
"\"The ups17BasicBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups17ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups17Compliances",
"2",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support full-featured functions, such as control."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups17BasicIdentGroup",
"ups17BasicBatteryGroup",
"ups17BasicInputGroup",
"ups17BasicOutputGroup",
"ups17BasicAlarmGroup",
"ups17BasicTestGroup",
"ups17BasicControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups17BasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
full-featured functions, such as control."
MODULE -- this module
MANDATORY-GROUPS { ups17BasicIdentGroup,
ups17BasicBatteryGroup, ups17BasicInputGroup,
ups17BasicOutputGroup, ups17BasicAlarmGroup,
ups17BasicTestGroup, ups17BasicControlGroup }
OBJECT ups17AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups17AlarmOnBattery, ups17AlarmLowBattery,
ups17AlarmDepletedBattery, ups17AlarmTempBad,
ups17AlarmInputBad, ups17AlarmOutputOverload,
ups17AlarmOnBypass, ups17AlarmBypassBad,
ups17AlarmOutputOffAsRequested,
ups17AlarmUpsOffAsRequested, ups17AlarmUpsOutputOff,
ups17AlarmUpsSystemOff, ups17AlarmGeneralFault,
ups17AlarmDiagnosticTestFailed,
ups17AlarmCommunicationsLost, ups17AlarmShutdownPending,
and ups17AlarmTestInProgress."
OBJECT ups17TestId
DESCRIPTION
"Support of all `well known' test types is not
required. If no tests are supported, then the only
well known test type which must be supported is
ups17TestNoTestsInitiated."
OBJECT ups17OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups17BasicBypassGroup
DESCRIPTION
"The ups17BasicBypassGroup is only required for UPSs
that have a Bypass present."
OBJECT ups17ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups17Compliances 2 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages: