ups29BasicCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support full-featured functions, such as control.
{1 3 6 1 4 1 53973 1 1 30 3 1 2}
The compliance statement for UPSs that support full-featured functions, such as control.
Status in source: current.
Names: ups29BasicCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups29BasicCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support full-featured functions, such as control.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups29BasicIdentGroup",
",",
"ups29BasicBatteryGroup",
",",
"ups29BasicInputGroup",
",",
"ups29BasicOutputGroup",
",",
"ups29BasicAlarmGroup",
",",
"ups29BasicTestGroup",
",",
"ups29BasicControlGroup",
"}",
"OBJECT",
"ups29AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups29AlarmOnBattery, ups29AlarmLowBattery, ups29AlarmDepletedBattery, ups29AlarmTempBad, ups29AlarmInputBad, ups29AlarmOutputOverload, ups29AlarmOnBypass, ups29AlarmBypassBad, ups29AlarmOutputOffAsRequested, ups29AlarmUpsOffAsRequested, ups29AlarmUpsOutputOff, ups29AlarmUpsSystemOff, ups29AlarmGeneralFault, ups29AlarmDiagnosticTestFailed, ups29AlarmCommunicationsLost, ups29AlarmShutdownPending, and ups29AlarmTestInProgress.\"",
"OBJECT",
"ups29TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. If no tests are supported, then the only well known test type which must be supported is ups29TestNoTestsInitiated.\"",
"OBJECT",
"ups29OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups29BasicBypassGroup",
"DESCRIPTION",
"\"The ups29BasicBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups29ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups29Compliances",
"2",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support full-featured functions, such as control."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups29BasicIdentGroup",
"ups29BasicBatteryGroup",
"ups29BasicInputGroup",
"ups29BasicOutputGroup",
"ups29BasicAlarmGroup",
"ups29BasicTestGroup",
"ups29BasicControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups29BasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
full-featured functions, such as control."
MODULE -- this module
MANDATORY-GROUPS { ups29BasicIdentGroup,
ups29BasicBatteryGroup, ups29BasicInputGroup,
ups29BasicOutputGroup, ups29BasicAlarmGroup,
ups29BasicTestGroup, ups29BasicControlGroup }
OBJECT ups29AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups29AlarmOnBattery, ups29AlarmLowBattery,
ups29AlarmDepletedBattery, ups29AlarmTempBad,
ups29AlarmInputBad, ups29AlarmOutputOverload,
ups29AlarmOnBypass, ups29AlarmBypassBad,
ups29AlarmOutputOffAsRequested,
ups29AlarmUpsOffAsRequested, ups29AlarmUpsOutputOff,
ups29AlarmUpsSystemOff, ups29AlarmGeneralFault,
ups29AlarmDiagnosticTestFailed,
ups29AlarmCommunicationsLost, ups29AlarmShutdownPending,
and ups29AlarmTestInProgress."
OBJECT ups29TestId
DESCRIPTION
"Support of all `well known' test types is not
required. If no tests are supported, then the only
well known test type which must be supported is
ups29TestNoTestsInitiated."
OBJECT ups29OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups29BasicBypassGroup
DESCRIPTION
"The ups29BasicBypassGroup is only required for UPSs
that have a Bypass present."
OBJECT ups29ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups29Compliances 2 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages:
Downloaded: 2026-10-24T02:14:13.121331+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.53973.1.1.30.3.1.1 | ups29SubsetCompliance | 0 | 0 | |
| 1.3.6.1.4.1.53973.1.1.30.3.1.3 | ups29FullCompliance | 0 | 0 |