ups29FullCompliance — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
The compliance statement for UPSs that support advanced full-featured functions.
{1 3 6 1 4 1 53973 1 1 30 3 1 3}
The compliance statement for UPSs that support advanced full-featured functions.
Status in source: current.
Names: ups29FullCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"ups29FullCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for UPSs that support advanced full-featured functions.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"ups29FullIdentGroup",
",",
"ups29FullBatteryGroup",
",",
"ups29FullInputGroup",
",",
"ups29FullOutputGroup",
",",
"ups29FullAlarmGroup",
",",
"ups29FullTestGroup",
",",
"ups29FullControlGroup",
"}",
"OBJECT",
"ups29AlarmDescr",
"DESCRIPTION",
"\"Support of all `well known' alarm types is not required. The well known alarm types which must be supported are: ups29AlarmBatteryBad, ups29AlarmOnBattery, ups29AlarmLowBattery, ups29AlarmDepletedBattery, ups29AlarmTempBad, ups29AlarmInputBad, ups29AlarmOnBypass, ups29AlarmBypassBad, ups29AlarmOutputOffAsRequested, ups29AlarmUpsOffAsRequested, ups29AlarmUpsOutputOff, ups29AlarmUpsSystemOff, ups29AlarmGeneralFault, ups29AlarmDiagnosticTestFailed, ups29AlarmCommunicationsLost, ups29AlarmShutdownPending, and ups29AlarmTestInProgress.\"",
"OBJECT",
"ups29TestId",
"DESCRIPTION",
"\"Support of all `well known' test types is not required. The well known test types which must be supported are: ups29TestNoTestsInitiated, ups29TestGeneralSystemsTest, and ups29TestQuickBatteryTest.\"",
"OBJECT",
"ups29OutputSource",
"SYNTAX",
"INTEGER",
"{",
"normal",
"(",
"2",
")",
",",
"battery",
"(",
"4",
")",
"}",
"DESCRIPTION",
"\"Support of the values other(1), none(2), bypass(4), booster(6) and reducer(7) is not required.\"",
"GROUP",
"ups29FullBypassGroup",
"DESCRIPTION",
"\"The ups29FullBypassGroup is only required for UPSs that have a Bypass present.\"",
"OBJECT",
"ups29ShutdownType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-write access is not required, i.e., compliant systems need not support more than one shutdown type.\"",
"::=",
"{",
"ups29Compliances",
"3",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for UPSs that support advanced full-featured functions."
],
null,
[
"ComplianceModules",
[
[
null,
[
"ups29FullIdentGroup",
"ups29FullBatteryGroup",
"ups29FullInputGroup",
"ups29FullOutputGroup",
"ups29FullAlarmGroup",
"ups29FullTestGroup",
"ups29FullControlGroup"
]
]
]
]
]
}Vendor MIB copy from the LibreNMS archive.
Module: ABBMODULARUPS-MIB
ups29FullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for UPSs that support
advanced full-featured functions."
MODULE -- this module
MANDATORY-GROUPS { ups29FullIdentGroup, ups29FullBatteryGroup,
ups29FullInputGroup, ups29FullOutputGroup,
ups29FullAlarmGroup, ups29FullTestGroup,
ups29FullControlGroup }
OBJECT ups29AlarmDescr
DESCRIPTION
"Support of all `well known' alarm types is not
required. The well known alarm types which must be
supported are: ups29AlarmBatteryBad, ups29AlarmOnBattery,
ups29AlarmLowBattery, ups29AlarmDepletedBattery,
ups29AlarmTempBad, ups29AlarmInputBad, ups29AlarmOnBypass,
ups29AlarmBypassBad, ups29AlarmOutputOffAsRequested,
ups29AlarmUpsOffAsRequested, ups29AlarmUpsOutputOff,
ups29AlarmUpsSystemOff, ups29AlarmGeneralFault,
ups29AlarmDiagnosticTestFailed,
ups29AlarmCommunicationsLost, ups29AlarmShutdownPending,
and ups29AlarmTestInProgress."
OBJECT ups29TestId
DESCRIPTION
"Support of all `well known' test types is not
required. The well known test types which must be
supported are: ups29TestNoTestsInitiated,
ups29TestGeneralSystemsTest, and
ups29TestQuickBatteryTest."
OBJECT ups29OutputSource
SYNTAX INTEGER {
normal(2),
battery(4)
}
DESCRIPTION
"Support of the values other(1), none(2), bypass(4),
booster(6) and reducer(7) is not required."
GROUP ups29FullBypassGroup
DESCRIPTION
"The ups29FullBypassGroup is only required for UPSs that
have a Bypass present."
OBJECT ups29ShutdownType
MIN-ACCESS read-only
DESCRIPTION
"Read-write access is not required, i.e., compliant
systems need not support more than one shutdown type."
::= { ups29Compliances 3 }{'SNMPv2-TC': ['DisplayString', 'TimeStamp', 'TimeInterval', 'TestAndIncr', 'AutonomousType', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter32', 'Gauge32', 'Integer32', 'Unsigned32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages: