OID reference

currentAlarmOID

1.3.6.1.4.1.5591.1.1.2.1.1

Description

This is the OID of the alarmed object whose current value makes an alarm active. In the case of the alarmed analog object, the value of this object is equal to the value of the index parameterOID of the propertyTable. In the case of the alarmed discrete object, the value of this object is equal to the value of the ind…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.5591.1.1.2.1 (currentAlarmEntry)
Node code
1
Node name
currentAlarmOID
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.5591.1.1.2.1.1
URN notation
urn:oid:1.3.6.1.4.1.5591.1.1.2.1.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 5591 1 1 2 1 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) scteRoot(5591) scteHmsTree(1) propertyIdent(1) currentAlarmTable(2) currentAlarmEntry(1) currentAlarmOID(1)}
OID-IRI notation
  • /1/3/6/1/4/1/5591/1/1/2/1/1
  • /ISO/Identified-Organization/6/1/4/1/5591/1/1/2/1/1
  • /ISO/3/6/1/4/1/5591/1/1/2/1/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID
  • /iso/identified-organization/dod/internet/private/enterprises/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID
  • /iso/identified-organization/dod/internet/private/vendor-objects/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID
  • /iso/org/dod/internet/private/enterprise/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID
  • /iso/org/dod/internet/private/enterprises/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID
  • /iso/org/dod/internet/private/ldap-enterprise/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID
  • /iso/org/dod/internet/private/vendor-objects/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID
  • /iso/iso-identified-organization/dod/internet/private/enterprise/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID
  • /iso/iso-identified-organization/dod/internet/private/enterprises/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID
  • /iso/iso-organization/dod/internet/private/enterprise/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID
  • /iso/iso-organization/dod/internet/private/enterprises/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID
  • /iso/iso-organization/dod/internet/private/vendor-objects/scteRoot/scteHmsTree/propertyIdent/currentAlarmTable/currentAlarmEntry/currentAlarmOID

SNMP properties

Value type
OBJECT IDENTIFIER
Maximum access defined by MIB
read-only
Status in MIB
current

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In SCTE-HMS-PROPERTY-MIB, the row index currentAlarmOID is declared as OBJECT IDENTIFIER. The index is encoded as the number of subidentifiers in the OID, followed by those subidentifiers. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

Published row index: currentAlarmOID.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.5591.1.1.2.1.1

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

currentAlarmOID  OBJECT-TYPE
     SYNTAX     OBJECT IDENTIFIER
     MAX-ACCESS read-only
     STATUS     current
     DESCRIPTION 
            "This is the OID of the alarmed object whose current value makes 
            an alarm active.  

            In the case of the alarmed analog object, the value of
            this object is equal to the value of the index parameterOID
            of the propertyTable.

            In the case of the alarmed discrete object, the value of
            this object is equal to the value of the index discreteParameterOID
            of the discretePropertyTable.

            Please note that in the case of the alarmed discrete object,
            the value of this object is not equal to the identity part of
            the OID of the instances in the corresponding row of
            the discretePropertyTable.


            Example 1. Object commonInternalTemperature (HMS024).

            If object commonInternalTemperature has a major alarm for
            a HIHI threshold value of 100 degrees Celsius defined in
            the propertyTable, and this alarm occurs then:

            (1) 'currentAlarmOID.12.commonInternalTemperature.0'
                instance will have the value 'commonInternalTemperature.0';

            (2) 'currentAlarmAlarmState.12.commonInternalTemperature.0'
                instance will have the value caasHIHI(2);

            (3) 'currentAlarmAlarmValue.12.commonInternalTemperature.0'
                instance will have the value 100. 

            Notice the presence of 12 in the OIDs of the instances
            above. Number 12 is the length of the 'commonInternalTemperature.0'
            OID, which is '1.3.6.1.4.1.5591.1.3.1.13.0'.


            Example 2. Object fnOpticalReceiverABSwitchState (HMS025).

            If object 'fnOpticalReceiverABSwitchState.1', which is the first
            instance of A/B switch in a fiber node, has a major alarm for
            a value pathB(2) defined in the discretePropertyTable, and this
            alarm occurs then:

            (1) 'currentAlarmOID.13.fnOpticalReceiverABSwitchState.1' instance
                will have the value 'fnOpticalReceiverABSwitchState.1'; 

            (2) 'currentAlarmAlarmState.13.fnOpticalReceiverABSwitchState.1'
                instance will have the value caasDiscreteMajor(6);

            (3) 'currentAlarmAlarmValue.13.fnOpticalReceiverABSwitchState.1'
                instance will have the value pathB(2).

            Notice the presence of 13 in the OIDs of the instances above. 
            Number 13 is the length of the 'fnOpticalReceiverABSwitchState.1'
            OID, which is '1.3.6.1.4.1.5591.1.5.13.1.4.1'.


            Example 3. Object heCommonTemperature (HMS111).

            If object 'commonInternalTemperature.1' has a major alarm for
            a HIHI threshold value of 60 degrees Celsius defined in
            the propertyTable, and this alarm occurs then:

            (1) 'currentAlarmOID.18.heCommonTemperature.1'
                instance will have the value 'heCommonTemperature.1';

            (2) 'currentAlarmAlarmState.18.heCommonTemperature.1'
                instance will have the value caasHIHI(2);

            (3) 'currentAlarmAlarmValue.18.heCommonTemperature.1'
                instance will have the value 600. 

            Notice the presence of 18 in the OIDs of the instances
            above. Number 18 is the length of the 'heCommonTemperature.1'
            OID, which is '1.3.6.1.4.1.5591.1.11.2.1.1.1.1.1.1.2.1'.


            Example 4. Object heOpTxLaserOutputStatus (HMS112).

            If object 'heOpTxLaserOutputStatus.1.2', which is the second laser
            instance in the first instance of the headend optical transmitter,
            has a major alarm for a value off(1) defined in
            the discretePropertyTable, and this alarm occurs then:

            (1) 'currentAlarmOID.18.heOpTxLaserOutputStatus.1.2' instance
                will have the value 'heOpTxLaserOutputStatus.1.2'; 

            (2) 'currentAlarmAlarmState.18.heOpTxLaserOutputStatus.1.2'
                instance will have the value caasDiscreteMajor(6);

            (3) 'currentAlarmAlarmValue.18.heOpTxLaserOutputStatus.1.2'
                instance will have the value off(1).

            Notice the presence of 18 in the OIDs of the instances above. 
            Number 18 is the length of the 'heOpTxLaserOutputStatus.2'
            OID, which is '1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.8.1.2'.
            "
     ::= { currentAlarmEntry 1 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This is the OID of the alarmed object whose current value makes an alarm active. In the case of the alarmed analog object, the value of this object is equal to the value of the index parameterOID of the propertyTable. In the case of the alarmed discrete object, the value of this object is equal to the value of the index discreteParameterOID of the discretePropertyTable. Please note that in the case of the alarmed discrete object, the value of this object is not equal to the identity part of the OID of the instances in the corresponding row of the discretePropertyTable. Example 1. Object commonInternalTemperature (HMS024). If object commonInternalTemperature has a major alarm for a HIHI threshold value of 100 degrees Celsius defined in the propertyTable, and this alarm occurs then: (1) 'currentAlarmOID.12.commonInternalTemperature.0' instance will have the value 'commonInternalTemperature.0'; (2) 'currentAlarmAlarmState.12.commonInternalTemperature.0' instance will have the value caasHIHI(2); (3) 'currentAlarmAlarmValue.12.commonInternalTemperature.0' instance will have the value 100. Notice the presence of 12 in the OIDs of the instances above. Number 12 is the length of the 'commonInternalTemperature.0' OID, which is '1.3.6.1.4.1.5591.1.3.1.13.0'. Example 2. Object fnOpticalReceiverABSwitchState (HMS025). If object 'fnOpticalReceiverABSwitchState.1', which is the first instance of A/B switch in a fiber node, has a major alarm for a value pathB(2) defined in the discretePropertyTable, and this alarm occurs then: (1) 'currentAlarmOID.13.fnOpticalReceiverABSwitchState.1' instance will have the value 'fnOpticalReceiverABSwitchState.1'; (2) 'currentAlarmAlarmState.13.fnOpticalReceiverABSwitchState.1' instance will have the value caasDiscreteMajor(6); (3) 'currentAlarmAlarmValue.13.fnOpticalReceiverABSwitchState.1' instance will have the value pathB(2). Notice the presence of 13 in the OIDs of the instances above. Number 13 is the length of the 'fnOpticalReceiverABSwitchState.1' OID, which is '1.3.6.1.4.1.5591.1.5.13.1.4.1'. Example 3. Object heCommonTemperature (HMS111). If object 'commonInternalTemperature.1' has a major alarm for a HIHI threshold value of 60 degrees Celsius defined in the propertyTable, and this alarm occurs then: (1) 'currentAlarmOID.18.heCommonTemperature.1' instance will have the value 'heCommonTemperature.1'; (2) 'currentAlarmAlarmState.18.heCommonTemperature.1' instance will have the value caasHIHI(2); (3) 'currentAlarmAlarmValue.18.heCommonTemperature.1' instance will have the value 600. Notice the presence of 18 in the OIDs of the instances above. Number 18 is the length of the 'heCommonTemperature.1' OID, which is '1.3.6.1.4.1.5591.1.11.2.1.1.1.1.1.1.2.1'. Example 4. Object heOpTxLaserOutputStatus (HMS112). If object 'heOpTxLaserOutputStatus.1.2', which is the second laser instance in the first instance of the headend optical transmitter, has a major alarm for a value off(1) defined in the discretePropertyTable, and this alarm occurs then: (1) 'currentAlarmOID.18.heOpTxLaserOutputStatus.1.2' instance will have the value 'heOpTxLaserOutputStatus.1.2'; (2) 'currentAlarmAlarmState.18.heOpTxLaserOutputStatus.1.2' instance will have the value caasDiscreteMajor(6); (3) 'currentAlarmAlarmValue.18.heOpTxLaserOutputStatus.1.2' instance will have the value off(1). Notice the presence of 18 in the OIDs of the instances above. Number 18 is the length of the 'heOpTxLaserOutputStatus.2' OID, which is '1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.8.1.2'.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Netdisco MIB archive copies1 record · 2 sources

Description 1

currentAlarmOID · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Netdisco MIB archive copies2 sources

Status in source: current.

Names: currentAlarmOID

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "currentAlarmOID",
    "OBJECT-TYPE",
    "SYNTAX",
    "OBJECT",
    "IDENTIFIER",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This is the OID of the alarmed object whose current value makes an alarm active. In the case of the alarmed analog object, the value of this object is equal to the value of the index parameterOID of the propertyTable. In the case of the alarmed discrete object, the value of this object is equal to the value of the index discreteParameterOID of the discretePropertyTable. Please note that in the case of the alarmed discrete object, the value of this object is not equal to the identity part of the OID of the instances in the corresponding row of the discretePropertyTable. Example 1. Object commonInternalTemperature (HMS024). If object commonInternalTemperature has a major alarm for a HIHI threshold value of 100 degrees Celsius defined in the propertyTable, and this alarm occurs then: (1) 'currentAlarmOID.12.commonInternalTemperature.0' instance will have the value 'commonInternalTemperature.0'; (2) 'currentAlarmAlarmState.12.commonInternalTemperature.0' instance will have the value caasHIHI(2); (3) 'currentAlarmAlarmValue.12.commonInternalTemperature.0' instance will have the value 100. Notice the presence of 12 in the OIDs of the instances above. Number 12 is the length of the 'commonInternalTemperature.0' OID, which is '1.3.6.1.4.1.5591.1.3.1.13.0'. Example 2. Object fnOpticalReceiverABSwitchState (HMS025). If object 'fnOpticalReceiverABSwitchState.1', which is the first instance of A/B switch in a fiber node, has a major alarm for a value pathB(2) defined in the discretePropertyTable, and this alarm occurs then: (1) 'currentAlarmOID.13.fnOpticalReceiverABSwitchState.1' instance will have the value 'fnOpticalReceiverABSwitchState.1'; (2) 'currentAlarmAlarmState.13.fnOpticalReceiverABSwitchState.1' instance will have the value caasDiscreteMajor(6); (3) 'currentAlarmAlarmValue.13.fnOpticalReceiverABSwitchState.1' instance will have the value pathB(2). Notice the presence of 13 in the OIDs of the instances above. Number 13 is the length of the 'fnOpticalReceiverABSwitchState.1' OID, which is '1.3.6.1.4.1.5591.1.5.13.1.4.1'. Example 3. Object heCommonTemperature (HMS111). If object 'commonInternalTemperature.1' has a major alarm for a HIHI threshold value of 60 degrees Celsius defined in the propertyTable, and this alarm occurs then: (1) 'currentAlarmOID.18.heCommonTemperature.1' instance will have the value 'heCommonTemperature.1'; (2) 'currentAlarmAlarmState.18.heCommonTemperature.1' instance will have the value caasHIHI(2); (3) 'currentAlarmAlarmValue.18.heCommonTemperature.1' instance will have the value 600. Notice the presence of 18 in the OIDs of the instances above. Number 18 is the length of the 'heCommonTemperature.1' OID, which is '1.3.6.1.4.1.5591.1.11.2.1.1.1.1.1.1.2.1'. Example 4. Object heOpTxLaserOutputStatus (HMS112). If object 'heOpTxLaserOutputStatus.1.2', which is the second laser instance in the first instance of the headend optical transmitter, has a major alarm for a value off(1) defined in the discretePropertyTable, and this alarm occurs then: (1) 'currentAlarmOID.18.heOpTxLaserOutputStatus.1.2' instance will have the value 'heOpTxLaserOutputStatus.1.2'; (2) 'currentAlarmAlarmState.18.heOpTxLaserOutputStatus.1.2' instance will have the value caasDiscreteMajor(6); (3) 'currentAlarmAlarmValue.18.heOpTxLaserOutputStatus.1.2' instance will have the value off(1). Notice the presence of 18 in the OIDs of the instances above. Number 18 is the length of the 'heOpTxLaserOutputStatus.2' OID, which is '1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.8.1.2'. \"",
    "::=",
    "{",
    "currentAlarmEntry",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "OBJECT IDENTIFIER",
      null
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This is the OID of the alarmed object whose current value makes an alarm active. In the case of the alarmed analog object, the value of this object is equal to the value of the index parameterOID of the propertyTable. In the case of the alarmed discrete object, the value of this object is equal to the value of the index discreteParameterOID of the discretePropertyTable. Please note that in the case of the alarmed discrete object, the value of this object is not equal to the identity part of the OID of the instances in the corresponding row of the discretePropertyTable. Example 1. Object commonInternalTemperature (HMS024). If object commonInternalTemperature has a major alarm for a HIHI threshold value of 100 degrees Celsius defined in the propertyTable, and this alarm occurs then: (1) 'currentAlarmOID.12.commonInternalTemperature.0' instance will have the value 'commonInternalTemperature.0'; (2) 'currentAlarmAlarmState.12.commonInternalTemperature.0' instance will have the value caasHIHI(2); (3) 'currentAlarmAlarmValue.12.commonInternalTemperature.0' instance will have the value 100. Notice the presence of 12 in the OIDs of the instances above. Number 12 is the length of the 'commonInternalTemperature.0' OID, which is '1.3.6.1.4.1.5591.1.3.1.13.0'. Example 2. Object fnOpticalReceiverABSwitchState (HMS025). If object 'fnOpticalReceiverABSwitchState.1', which is the first instance of A/B switch in a fiber node, has a major alarm for a value pathB(2) defined in the discretePropertyTable, and this alarm occurs then: (1) 'currentAlarmOID.13.fnOpticalReceiverABSwitchState.1' instance will have the value 'fnOpticalReceiverABSwitchState.1'; (2) 'currentAlarmAlarmState.13.fnOpticalReceiverABSwitchState.1' instance will have the value caasDiscreteMajor(6); (3) 'currentAlarmAlarmValue.13.fnOpticalReceiverABSwitchState.1' instance will have the value pathB(2). Notice the presence of 13 in the OIDs of the instances above. Number 13 is the length of the 'fnOpticalReceiverABSwitchState.1' OID, which is '1.3.6.1.4.1.5591.1.5.13.1.4.1'. Example 3. Object heCommonTemperature (HMS111). If object 'commonInternalTemperature.1' has a major alarm for a HIHI threshold value of 60 degrees Celsius defined in the propertyTable, and this alarm occurs then: (1) 'currentAlarmOID.18.heCommonTemperature.1' instance will have the value 'heCommonTemperature.1'; (2) 'currentAlarmAlarmState.18.heCommonTemperature.1' instance will have the value caasHIHI(2); (3) 'currentAlarmAlarmValue.18.heCommonTemperature.1' instance will have the value 600. Notice the presence of 18 in the OIDs of the instances above. Number 18 is the length of the 'heCommonTemperature.1' OID, which is '1.3.6.1.4.1.5591.1.11.2.1.1.1.1.1.1.2.1'. Example 4. Object heOpTxLaserOutputStatus (HMS112). If object 'heOpTxLaserOutputStatus.1.2', which is the second laser instance in the first instance of the headend optical transmitter, has a major alarm for a value off(1) defined in the discretePropertyTable, and this alarm occurs then: (1) 'currentAlarmOID.18.heOpTxLaserOutputStatus.1.2' instance will have the value 'heOpTxLaserOutputStatus.1.2'; (2) 'currentAlarmAlarmState.18.heOpTxLaserOutputStatus.1.2' instance will have the value caasDiscreteMajor(6); (3) 'currentAlarmAlarmValue.18.heOpTxLaserOutputStatus.1.2' instance will have the value off(1). Notice the presence of 18 in the OIDs of the instances above. Number 18 is the length of the 'heOpTxLaserOutputStatus.2' OID, which is '1.3.6.1.4.1.5591.1.11.1.1.1.1.3.1.8.1.2'."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.5591)

Burckhardt Robin

Siblings (2)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.5591.1.1.2.1.2 currentAlarmAlarmState00
1.3.6.1.4.1.5591.1.1.2.1.3 currentAlarmAlarmValue00