Reference record for OID 1.3.6.1.4.1.564.101.1.9.1


parent
1.3.6.1.4.1.564.101.1.9 (elFM)
node code
1
node name
elFMFillAlarmLogTable
dot oid
1.3.6.1.4.1.564.101.1.9.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) telco(564) edgeLink(101) elM13v1(1) elFM(9) elFMFillAlarmLogTable(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) telco(564) edgeLink(101) elM13v1(1) elFM(9) elFMFillAlarmLogTable(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) telco(564) edgeLink(101) elM13v1(1) elFM(9) elFMFillAlarmLogTable(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) telco(564) edgeLink(101) elM13v1(1) elFM(9) elFMFillAlarmLogTable(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) telco(564) edgeLink(101) elM13v1(1) elFM(9) elFMFillAlarmLogTable(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) telco(564) edgeLink(101) elM13v1(1) elFM(9) elFMFillAlarmLogTable(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/telco/edgeLink/elM13v1/elFM/elFMFillAlarmLogTable
  • /iso/identified-organization/dod/internet/private/enterprises/telco/edgeLink/elM13v1/elFM/elFMFillAlarmLogTable
  • /iso/org/dod/internet/private/enterprise/telco/edgeLink/elM13v1/elFM/elFMFillAlarmLogTable
  • /iso/org/dod/internet/private/enterprises/telco/edgeLink/elM13v1/elFM/elFMFillAlarmLogTable
  • /iso/iso-identified-organization/dod/internet/private/enterprise/telco/edgeLink/elM13v1/elFM/elFMFillAlarmLogTable
  • /iso/iso-identified-organization/dod/internet/private/enterprises/telco/edgeLink/elM13v1/elFM/elFMFillAlarmLogTable
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/564/101/1/9/1

    Description by mibdepot

    Take a snapshot of the alarm log. Must be done before
    reading the log into the alarm log table, elFMAlmLogTable.
    On a read, the value indeterminate(1) will be returned
    if the SNMP variable was never set to fillAlarmLogTable(2),
    otherwise fillAlarmLogTable(2) will be returned.

    Parsed from file el.mib.txt
    Company: None
    Module: EDGELINK-MIB

    Description by circitor

    Take a snapshot of the alarm log. Must be done before
    reading the log into the alarm log table, elFMAlmLogTable.
    On a read, the value indeterminate(1) will be returned
    if the SNMP variable was never set to fillAlarmLogTable(2),
    otherwise fillAlarmLogTable(2) will be returned.

    Parsed from file EDGELINK-MIB.mib
    Module: EDGELINK-MIB

    Information by oid_info

    Vendor: Telco Systems NAC
    Module: EDGELINK-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    elFMFillAlarmLogTable OBJECT-TYPE SYNTAX INTEGER { indeterminate(1), fillAlarmLogTable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Take a snapshot of the alarm log. Must be done before reading the log into the alarm log table, elFMAlmLogTable. On a read, the value indeterminate(1) will be returned if the SNMP variable was never set to fillAlarmLogTable(2), otherwise fillAlarmLogTable(2) will be returned." ::= { elFM 1 }

    Information by circitor

    elFMFillAlarmLogTable OBJECT-TYPE SYNTAX INTEGER { indeterminate(1), fillAlarmLogTable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Take a snapshot of the alarm log. Must be done before reading the log into the alarm log table, elFMAlmLogTable. On a read, the value indeterminate(1) will be returned if the SNMP variable was never set to fillAlarmLogTable(2), otherwise fillAlarmLogTable(2) will be returned." ::= { elFM 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.564)

    Hirani Harry

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.564.101.1.9.1.0 elFMFillAlarmLogTable 0 0 None

    Brothers (3)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.564.101.1.9.2 elFMClearAlarmLog 1 1 Clears the system's alarm log. On a read, the value
    indeterminate(1) will be returned if the SNMP variable
    was never set to clear…
    1.3.6.1.4.1.564.101.1.9.3 elFMDS1AutoSenseMode 1 1 The AutoSense Mode will be enabled or Disabled on all
    the 28 Ds1 channels. The Rescan command will scan all
    the equipped DS1 Inpu…
    1.3.6.1.4.1.564.101.1.9.4 elFMDS1InputAlarmMode 1 1 This command changes the severity of the DS1 LOS as
    either Major alarm or status depending on the selection.