Reference record for OID 1.3.6.1.4.1.5746.1.2.6.7


parent
1.3.6.1.4.1.5746.1.2.6 (test)
node code
7
node name
testTime
dot oid
1.3.6.1.4.1.5746.1.2.6.7
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lanex(5746) telecom(1) OptiLine16(2) test(6) testTime(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lanex(5746) telecom(1) OptiLine16(2) test(6) testTime(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) lanex(5746) telecom(1) OptiLine16(2) test(6) testTime(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) lanex(5746) telecom(1) OptiLine16(2) test(6) testTime(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lanex(5746) telecom(1) OptiLine16(2) test(6) testTime(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lanex(5746) telecom(1) OptiLine16(2) test(6) testTime(7)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/lanex/telecom/OptiLine16/test/testTime
  • /iso/identified-organization/dod/internet/private/enterprises/lanex/telecom/OptiLine16/test/testTime
  • /iso/org/dod/internet/private/enterprise/lanex/telecom/OptiLine16/test/testTime
  • /iso/org/dod/internet/private/enterprises/lanex/telecom/OptiLine16/test/testTime
  • /iso/iso-identified-organization/dod/internet/private/enterprise/lanex/telecom/OptiLine16/test/testTime
  • /iso/iso-identified-organization/dod/internet/private/enterprises/lanex/telecom/OptiLine16/test/testTime
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/5746/1/2/6/7

    Description by mibdepot

    Deklarowany czas trwania testu w sekundach. Maks. 24 godziny

    Parsed from file OptiLine16_pl.my.txt
    Company: None
    Module: TM63-MIB

    Description by circitor

    Deklarowany czas trwania testu w sekundach. Maks. 24 godziny

    Parsed from file TM63-MIB.mib
    Module: TM63-MIB

    Information by oid_info

    Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.

    Information by mibdepot

    testTime OBJECT-TYPE SYNTAX INTEGER (0..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "Deklarowany czas trwania testu w sekundach. Maks. 24 godziny" ::= {test 7}

    Information by circitor

    testTime OBJECT-TYPE SYNTAX INTEGER (0..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "Deklarowany czas trwania testu w sekundach. Maks. 24 godziny" ::= {test 7}

    First Registration Authority (recovered by parent 1.3.6.1.4.1.5746)

    Kusinski Dariusz

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.5746.1.2.6.7.0 testTime 0 0 None

    Brothers (16)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.5746.1.2.6.1 testTributaryChannelLoopType1 1 1 Zalaczenie petli kanalu
    skladowego 1 - 16 do interfejsu.
    (ALx = 1 za³¹czenie pêtli, ALx = 0 wy³¹czene pêtli na kanale x)
    bit : …
    1.3.6.1.4.1.5746.1.2.6.2 testTributaryChannelLoopType2 1 1 Zalaczenie petli kanalu
    skladowego 1 - 16 od interfejsu.
    (RLx = 1 za³¹czenie pêtli, RLx = 0 wy³¹czene pêtli na kanale x)
    bit : …
    1.3.6.1.4.1.5746.1.2.6.3 testMainChannelLoopType1 1 1 Zalaczenie petli kanalu
    zbiorczego do interfejsu
    1.3.6.1.4.1.5746.1.2.6.4 testMainChannelLoopType2 1 1 Zalaczenie petli kanalu
    zbiorczego od interfejsu
    1.3.6.1.4.1.5746.1.2.6.5 testGeneratorDetector 1 1 numer generatora/detektora
    wykorzystywanego do testu
    1..16 - generator w kierunku kanalu skladowego (E1) 1..16
    17 - generator w ki…
    1.3.6.1.4.1.5746.1.2.6.6 testGCT 1 1 Sterowanie za³¹czaniem/wy³¹czaniem generatorów testowych wybranych kana³ów E1/E3:
    1 – generator za³¹czony
    0 – generator wy³¹czony
    1.3.6.1.4.1.5746.1.2.6.8 testSyncTime 1 1 czas pomiaru gdy jest synchronizacja
    1.3.6.1.4.1.5746.1.2.6.9 testNoSyncTime 1 1 czas pomiaru gdy brak synchronizacji
    1.3.6.1.4.1.5746.1.2.6.10 testErrorsPerSec 1 1 Biezaca liczba bledow w cyklu sekundowym
    1.3.6.1.4.1.5746.1.2.6.11 testTotalErrorNumber 1 1 Calkowita liczba bledow
    1.3.6.1.4.1.5746.1.2.6.12 testBER 1 1 Stopa bledow w formacie:
    P.Pe-LL (notacja naukowa)
    przyklad: 2.3e-09
    1.3.6.1.4.1.5746.1.2.6.13 testErrorsPerSecBWSZ 1 1 Biezaca liczba bledow BWSZ w cyklu sekundowym
    1.3.6.1.4.1.5746.1.2.6.14 testTotalErrorNumberBWSZ 1 1 Calkowita liczba bledow BWSZ
    1.3.6.1.4.1.5746.1.2.6.15 testBERBWSZ 1 1 Stopa bledow BWSZ w formacie:
    P.Pe-LL (notacja naukowa)
    przyklad: 2.3e-09
    1.3.6.1.4.1.5746.1.2.6.16 testSyncYesNo 1 1 Flaga synchronizacji (1 – oznacza detekcjê ci¹gu testowego)
    1.3.6.1.4.1.5746.1.2.6.17 testStatus 1 1 status wykonywania testu
    0 – OFF – test wy³¹czony
    1 – ON – test za³¹czony
    2 – RUN – test trwa
    3 – READY – gotowoœæ do rozpoczêci…