OID reference

nbsSffDiagsSoftRateSelect

1.3.6.1.4.1.629.204.1.3.1.1.48

Description

Read/write bit that allows software rate select control. Writing 1 selects full bandwidth operation. This bit is OR'd with the hard Rate_Select, AS(0) or RS(0) pin value. See Table 3.11 for timing requirements. Default at power up is logic zero/low. If Soft Rate Select is not implemented, the transceiver ignores the v…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.629.204.1.3.1.1 (nbsSffDiagsEntry)
Node code
48
Node name
nbsSffDiagsSoftRateSelect
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.629.204.1.3.1.1.48
URN notation
urn:oid:1.3.6.1.4.1.629.204.1.3.1.1.48
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 629 204 1 3 1 1 48}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nbase(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nbs(629) nbsSffMib(204) nbsSffObjects(1) nbsSffDiagnosticsGrp(3) nbsSffDiagsTable(1) nbsSffDiagsEntry(1) nbsSffDiagsSoftRateSelect(48)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/629/204/1/3/1/1/48
  • /ISO/Identified-Organization/6/1/4/1/629/204/1/3/1/1/48
  • /ISO/3/6/1/4/1/629/204/1/3/1/1/48
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/nbase/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • /iso/identified-organization/dod/internet/private/enterprise/nbs/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • /iso/identified-organization/dod/internet/private/enterprises/nbase/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • /iso/identified-organization/dod/internet/private/enterprises/nbs/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nbase/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nbs/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • /iso/identified-organization/dod/internet/private/vendor-objects/nbase/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • /iso/identified-organization/dod/internet/private/vendor-objects/nbs/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • /iso/org/dod/internet/private/enterprise/nbase/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • /iso/org/dod/internet/private/enterprise/nbs/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • /iso/org/dod/internet/private/enterprises/nbase/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • /iso/org/dod/internet/private/enterprises/nbs/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • /iso/org/dod/internet/private/ldap-enterprise/nbase/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • /iso/org/dod/internet/private/ldap-enterprise/nbs/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • /iso/org/dod/internet/private/vendor-objects/nbase/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • /iso/org/dod/internet/private/vendor-objects/nbs/nbsSffMib/nbsSffObjects/nbsSffDiagnosticsGrp/nbsSffDiagsTable/nbsSffDiagsEntry/nbsSffDiagsSoftRateSelect
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.

Published row index: nbsSffMsaPhysicalIfIndex.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.629.204.1.3.1.1.48

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

nbsSffDiagsSoftRateSelect OBJECT-TYPE
    SYNTAX      INTEGER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Read/write bit that allows software rate select control.
         Writing 1 selects full bandwidth operation. This bit is
         OR'd with the hard Rate_Select, AS(0) or RS(0) pin value.
         See Table 3.11 for timing requirements. Default at power
         up is logic zero/low. If Soft Rate Select is not implemented,
         the transceiver ignores the value of this bit. Note: Specific
         transceiver behaviors of this bit are identified in Table 3.6a
         and referenced documents. See Table 3.18a, byte 118, bit 3 for
         Soft RS(1) Select. Byte 110, bit 3 of A2h"
    REFERENCE   "Diagnostic Monitoring Interface for Optical
                 Transceivers, SFF-8472 Rev 10.3 Table 3.17"

    ::= { nbsSffDiagsEntry 48 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Read/write bit that allows software rate select control. Writing 1 selects full bandwidth operation. This bit is OR'd with the hard Rate_Select, AS(0) or RS(0) pin value. See Table 3.11 for timing requirements. Default at power up is logic zero/low. If Soft Rate Select is not implemented, the transceiver ignores the value of this bit. Note: Specific transceiver behaviors of this bit are identified in Table 3.6a and referenced documents. See Table 3.18a, byte 118, bit 3 for Soft RS(1) Select. Byte 110, bit 3 of A2h

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

nbsSffDiagsSoftRateSelect · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: nbsSffDiagsSoftRateSelect

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "nbsSffDiagsSoftRateSelect",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Read/write bit that allows software rate select control. Writing 1 selects full bandwidth operation. This bit is OR'd with the hard Rate_Select, AS(0) or RS(0) pin value. See Table 3.11 for timing requirements. Default at power up is logic zero/low. If Soft Rate Select is not implemented, the transceiver ignores the value of this bit. Note: Specific transceiver behaviors of this bit are identified in Table 3.6a and referenced documents. See Table 3.18a, byte 118, bit 3 for Soft RS(1) Select. Byte 110, bit 3 of A2h\"",
    "REFERENCE",
    "\"Diagnostic Monitoring Interface for Optical Transceivers, SFF-8472 Rev 10.3 Table 3.17\"",
    "::=",
    "{",
    "nbsSffDiagsEntry",
    "48",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Read/write bit that allows software rate select control. Writing 1 selects full bandwidth operation. This bit is OR'd with the hard Rate_Select, AS(0) or RS(0) pin value. See Table 3.11 for timing requirements. Default at power up is logic zero/low. If Soft Rate Select is not implemented, the transceiver ignores the value of this bit. Note: Specific transceiver behaviors of this bit are identified in Table 3.6a and referenced documents. See Table 3.18a, byte 118, bit 3 for Soft RS(1) Select. Byte 110, bit 3 of A2h"
    ],
    [
      "REFERENCE",
      "Diagnostic Monitoring Interface for Optical Transceivers, SFF-8472 Rev 10.3 Table 3.17"
    ],
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.629)

Rotenstein Sergiu

Siblings (62)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.629.204.1.3.1.1.1 nbsSffDiagsRateIdentifier00
1.3.6.1.4.1.629.204.1.3.1.1.2 nbsSffDiagsLinkLengthOm300
1.3.6.1.4.1.629.204.1.3.1.1.3 nbsSffDiagsLaserWavelength00
1.3.6.1.4.1.629.204.1.3.1.1.4 nbsSffDiagsLROutputImplemented00
1.3.6.1.4.1.629.204.1.3.1.1.5 nbsSffDiagsPowerLevelDeclaration00
1.3.6.1.4.1.629.204.1.3.1.1.6 nbsSffDiagsCooledTranDeclaration00
1.3.6.1.4.1.629.204.1.3.1.1.7 nbsSffDiagsAddressChangeRequired00
1.3.6.1.4.1.629.204.1.3.1.1.8 nbsSffDiagsPowerMeasurementType00
1.3.6.1.4.1.629.204.1.3.1.1.9 nbsSffDiagsExternallyCalibrated00
1.3.6.1.4.1.629.204.1.3.1.1.10 nbsSffDiagsInternallyCalibrated00
1.3.6.1.4.1.629.204.1.3.1.1.11 nbsSffDiagsDDMonitoringImplemented00
1.3.6.1.4.1.629.204.1.3.1.1.12 nbsSffDiagsOptRateSelectControl00
1.3.6.1.4.1.629.204.1.3.1.1.13 nbsSffDiagsOptAppSelectControl00
1.3.6.1.4.1.629.204.1.3.1.1.14 nbsSffDiagsOptSoftRSControlMon00
1.3.6.1.4.1.629.204.1.3.1.1.15 nbsSffDiagsOptSoftRxLoSMonitoring00
1.3.6.1.4.1.629.204.1.3.1.1.16 nbsSffDiagsOptSoftTxFaultMonitoring00
1.3.6.1.4.1.629.204.1.3.1.1.17 nbsSffDiagsOptSoftTxDisable00
1.3.6.1.4.1.629.204.1.3.1.1.18 nbsSffDiagsOptAlarmWarningFlags00
1.3.6.1.4.1.629.204.1.3.1.1.19 nbsSffDiags8472Compliance00
1.3.6.1.4.1.629.204.1.3.1.1.20 nbsSffDiagsTemperature00
1.3.6.1.4.1.629.204.1.3.1.1.21 nbsSffDiagsTempLowAlarm00
1.3.6.1.4.1.629.204.1.3.1.1.22 nbsSffDiagsTempLowWarn00
1.3.6.1.4.1.629.204.1.3.1.1.23 nbsSffDiagsTempHighWarn00
1.3.6.1.4.1.629.204.1.3.1.1.24 nbsSffDiagsTempHighAlarm00
1.3.6.1.4.1.629.204.1.3.1.1.25 nbsSffDiagsVoltage00
1.3.6.1.4.1.629.204.1.3.1.1.26 nbsSffDiagsVoltLowAlarm00
1.3.6.1.4.1.629.204.1.3.1.1.27 nbsSffDiagsVoltLowWarn00
1.3.6.1.4.1.629.204.1.3.1.1.28 nbsSffDiagsVoltHighWarn00
1.3.6.1.4.1.629.204.1.3.1.1.29 nbsSffDiagsVoltHighAlarm00
1.3.6.1.4.1.629.204.1.3.1.1.30 nbsSffDiagsBiasCurrent00
1.3.6.1.4.1.629.204.1.3.1.1.31 nbsSffDiagsBiasLowAlarm00
1.3.6.1.4.1.629.204.1.3.1.1.32 nbsSffDiagsBiasLowWarn00
1.3.6.1.4.1.629.204.1.3.1.1.33 nbsSffDiagsBiasHighWarn00
1.3.6.1.4.1.629.204.1.3.1.1.34 nbsSffDiagsBiasHighAlarm00
1.3.6.1.4.1.629.204.1.3.1.1.35 nbsSffDiagsTxPower00
1.3.6.1.4.1.629.204.1.3.1.1.36 nbsSffDiagsTxPowerLowAlarm00
1.3.6.1.4.1.629.204.1.3.1.1.37 nbsSffDiagsTxPowerLowWarn00
1.3.6.1.4.1.629.204.1.3.1.1.38 nbsSffDiagsTxPowerHighWarn00
1.3.6.1.4.1.629.204.1.3.1.1.39 nbsSffDiagsTxPowerHighAlarm00
1.3.6.1.4.1.629.204.1.3.1.1.40 nbsSffDiagsRxPower00
1.3.6.1.4.1.629.204.1.3.1.1.41 nbsSffDiagsRxPowerLowAlarm00
1.3.6.1.4.1.629.204.1.3.1.1.42 nbsSffDiagsRxPowerLowWarn00
1.3.6.1.4.1.629.204.1.3.1.1.43 nbsSffDiagsRxPowerHighWarn00
1.3.6.1.4.1.629.204.1.3.1.1.44 nbsSffDiagsRxPowerHighAlarm00
1.3.6.1.4.1.629.204.1.3.1.1.45 nbsSffDiagsDataReadyBarState00
1.3.6.1.4.1.629.204.1.3.1.1.46 nbsSffDiagsRxLosState00
1.3.6.1.4.1.629.204.1.3.1.1.47 nbsSffDiagsTxFaultState00
1.3.6.1.4.1.629.204.1.3.1.1.49 nbsSffDiagsRateSelectState000
1.3.6.1.4.1.629.204.1.3.1.1.50 nbsSffDiagsRS1State00
1.3.6.1.4.1.629.204.1.3.1.1.51 nbsSffDiagsSoftTxDisableSelect00