Description 1
The name of the power plant. This object should be set by the administrator.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.6302.2.1.1.5
The name of the power plant. This object should be set by the administrator.
Identification
{1 3 6 1 4 1 6302 2 1 1 5}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 4 distinct definitions; some records may not include a definition.
identSNMPCfgVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
The name of the power plant. This object should be set by
the administrator."
::= { ident 5 }identSNMPCfgVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
The name of the power plant. This object should be set by
the administrator."
::= { ident 5 }identSNMPCfgVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
The snmp cfg version"
::= { ident 5 }identSNMPCfgVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "
SNMP Config Version."
::= { ident 5 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
The name of the power plant. This object should be set by the administrator.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
The snmp cfg version
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 3
SNMP Config Version.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: identSNMPCfgVer
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"identSNMPCfgVer",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\" The name of the power plant. This object should be set by the administrator.\"",
"::=",
"{",
"ident",
"5",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The name of the power plant. This object should be set by the administrator."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: EES-POWER-FERRO-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Counter32', 'enterprises']}Related source files and packages:
Vendor MIB copy from the LibreNMS archive.
Module: NETSURE-MIB-004-A
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Counter32', 'enterprises']}Status in source: current.
Names: identSNMPCfgVer
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"identSNMPCfgVer",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\" The snmp cfg version\"",
"::=",
"{",
"ident",
"5",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The snmp cfg version"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: EES-POWER-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Counter32', 'enterprises']}Vendor MIB copy from the Observium Community archive.
Module: EES-POWER-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Counter32', 'enterprises']}Related source files and packages:
Status in source: current.
Names: identSNMPCfgVer
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"identSNMPCfgVer",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\" SNMP Config Version.\"",
"::=",
"{",
"ident",
"5",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"SNMP Config Version."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: NETSURE-NCU-MIB
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Counter32', 'enterprises']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6302.2.1.1.1 | identManufacturer | 0 | 0 | |
| 1.3.6.1.4.1.6302.2.1.1.2 | identModel | 0 | 0 | |
| 1.3.6.1.4.1.6302.2.1.1.3 | identControllerFirmwareVersion | 0 | 0 | |
| 1.3.6.1.4.1.6302.2.1.1.4 | identName | 0 | 0 | |
| 1.3.6.1.4.1.6302.2.1.1.6 | identControllerSerialNumber | 0 | 0 | |
| 1.3.6.1.4.1.6302.2.1.1.7 | identHWerVersion | 0 | 0 | |
| 1.3.6.1.4.1.6302.2.1.1.8 | identSiteLocation | 0 | 0 | |
| 1.3.6.1.4.1.6302.2.1.1.9 | identControllerConfigVer | 0 | 0 | |
| 1.3.6.1.4.1.6302.2.1.1.10 | identMacID | 0 | 0 | |
| 1.3.6.1.4.1.6302.2.1.1.11 | identSystemName | 0 | 0 | |
| 1.3.6.1.4.1.6302.2.1.1.12 | identProductModel | 0 | 0 | |
| 1.3.6.1.4.1.6302.2.1.1.13 | identCriticalAlarms | 0 | 0 | |
| 1.3.6.1.4.1.6302.2.1.1.14 | identPrimaryIp | 0 | 0 | |
| 1.3.6.1.4.1.6302.2.1.1.15 | identNTPMode | 0 | 0 | |
| 1.3.6.1.4.1.6302.2.1.1.17 | identSystemDateTime | 0 | 0 | |
| 1.3.6.1.4.1.6302.2.1.1.18 | identLocalZone | 0 | 0 |