Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"v5LinkNumberOfPcc",
"OBJECT-TYPE",
"SYNTAX",
"V5PccCount",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The number of Physical Communication Channel (Physcommchan or PCC) configured on this V5 link. V5 links are structured as 8000 frames per second of 32 timeslots each. A timeslot can carry voice data, or alternatively signalling, e.g. synchronization data, CRC's, or D-channel data. Timeslot 0 is always used for signalling by lower level layers of E1. For higher level signalling like D-channels, additional timeslots must be explicitly allocated - these are called physcommchans. Timeslots 16, 15 and 31 are available for this purpose. So, a V5 link can have from zero to three physcommchans. Timeslots are always allocated in the order mentioned above, that is the following configurations are possible: Timeslots allocated to v5LinkNumberOfPcc higher level signalling 0 - 1 16 2 16,15 3 16,15,31 Timeslots that are not used for signalling are available for voice data. So, a link can have from 28 to 31 voice data channels.\"",
"::=",
"{",
"v5LinkEntry",
"9",
"}"
],
"syntax_tree": [
[
"row",
"V5PccCount"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The number of Physical Communication Channel (Physcommchan or PCC) configured on this V5 link. V5 links are structured as 8000 frames per second of 32 timeslots each. A timeslot can carry voice data, or alternatively signalling, e.g. synchronization data, CRC's, or D-channel data. Timeslot 0 is always used for signalling by lower level layers of E1. For higher level signalling like D-channels, additional timeslots must be explicitly allocated - these are called physcommchans. Timeslots 16, 15 and 31 are available for this purpose. So, a V5 link can have from zero to three physcommchans. Timeslots are always allocated in the order mentioned above, that is the following configurations are possible: Timeslots allocated to v5LinkNumberOfPcc higher level signalling 0 - 1 16 2 16,15 3 16,15,31 Timeslots that are not used for signalling are available for voice data. So, a link can have from 28 to 31 voice data channels."
],
null,
null,
null,
null
]
}