Status in source: current.
Names: radioShifterCentralFrequency
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"radioShifterCentralFrequency",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\" This object specifies the central radio frequency requested by the managing systems. It is updated or by the agent when the radioShifterId object is set by the managing systems or directly by the managing system (in this case the agent must set the radioShifterId to '-1' value). This value is expressed in KHz.\"",
"::=",
"{",
"opticsIMRadioShifterEntry",
"3",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object specifies the central radio frequency requested by the managing systems. It is updated or by the agent when the radioShifterId object is set by the managing systems or directly by the managing system (in this case the agent must set the radioShifterId to '-1' value). This value is expressed in KHz."
],
null,
null,
null,
null
]
}
- Nokia networking MIB copies (LibreNMS/Observium Community)
· Publisher's source file: OPTICSIM-RADIO-TRS-COMMON-MIB
Vendor MIB copy from the LibreNMS archive.
Nokia support.
Module: OPTICSIM-RADIO-TRS-COMMON-MIB
See published definition above
Module imports
{'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['TruthValue', 'DisplayString', 'RowStatus', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'TSDIM-SUPPORT-MIB': ['tsdimEventObjectClassIdentifier', 'tsdimEventObjectInstanceIdentifier', 'tsdimEventNotificationId', 'tsdimEventTime', 'tsdimAlarmSeverity', 'tsdimAlarmSpecProblem', 'opticsIMAdditionalText', 'opticsIMAlarmType'], 'OPTICSIM-COMMON-TC': ['OpticsIMRadioChannelNumber', 'OpticsIMPmRetrievingTime'], 'OPTICSIM-RADIOREG-MIB': ['opticsimRadioMib', 'opticsimRadioMC'], 'OPTICSIM-RADIO-TRS-PDH-MIB': ['OpticsIMModulationTypeOrZero']}
· Download OPTICSIM-RADIO-TRS-COMMON-MIB
Related source files and packages:
- Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
· Publisher's source file: OPTICSIM-RADIO-TRS-COMMON-MIB
Vendor MIB copy from the LibreNMS archive.
Module: OPTICSIM-RADIO-TRS-COMMON-MIB
Same published definition
Module imports
{'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['TruthValue', 'DisplayString', 'RowStatus', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'TSDIM-SUPPORT-MIB': ['tsdimEventObjectClassIdentifier', 'tsdimEventObjectInstanceIdentifier', 'tsdimEventNotificationId', 'tsdimEventTime', 'tsdimAlarmSeverity', 'tsdimAlarmSpecProblem', 'opticsIMAdditionalText', 'opticsIMAlarmType'], 'OPTICSIM-COMMON-TC': ['OpticsIMRadioChannelNumber', 'OpticsIMPmRetrievingTime'], 'OPTICSIM-RADIOREG-MIB': ['opticsimRadioMib', 'opticsimRadioMC'], 'OPTICSIM-RADIO-TRS-PDH-MIB': ['OpticsIMModulationTypeOrZero']}
· Download OPTICSIM-RADIO-TRS-COMMON-MIB