Status in source: mandatory.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sfpDiagTxPower",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"A column in the sfpDiagTable, containing the freshly-measured transmit power of the specified SFP, encoded into a string. Five types of values are supported. In the following text, strings are enclosed in single quotes (a double quote marks the end of the DESCRIPTION field). 1. '-40.00 dBm' to '8.16 dBm', in 0.01 dBm increments. Note that ' dBm' is included in the string. 2. 'No Power'. This is a special case because an SFP reading of 0.00 mW cannot be converted to dBm (since log10(0.00) is undefined). 3. 'Not Applicable'. This is used for an electrical SFP. The technology for measuring transmitted power is optical. 4. 'Not Available'. The measurement could not be obtained (e.g. the specified SFP cage is empty). 5. 'Invalid'. The transmitted power, in mW, is negative (for example, due to incorrect external calibration constants in the SFP). A negative mW value is not valid in this context, and cannot be converted to dBm. ALCATEL NOTE: ACCESS: RO USAGE: NA PERSIST: NO INSRVMOD: NO RANGE: NA DEFVALUE: NA UNITS: NA SPARSE: NO DESCR: NA \"",
"::=",
"{",
"sfpDiagEntry",
"6",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"A column in the sfpDiagTable, containing the freshly-measured transmit power of the specified SFP, encoded into a string. Five types of values are supported. In the following text, strings are enclosed in single quotes (a double quote marks the end of the DESCRIPTION field). 1. '-40.00 dBm' to '8.16 dBm', in 0.01 dBm increments. Note that ' dBm' is included in the string. 2. 'No Power'. This is a special case because an SFP reading of 0.00 mW cannot be converted to dBm (since log10(0.00) is undefined). 3. 'Not Applicable'. This is used for an electrical SFP. The technology for measuring transmitted power is optical. 4. 'Not Available'. The measurement could not be obtained (e.g. the specified SFP cage is empty). 5. 'Invalid'. The transmitted power, in mW, is negative (for example, due to incorrect external calibration constants in the SFP). A negative mW value is not valid in this context, and cannot be converted to dBm. ALCATEL NOTE: ACCESS: RO USAGE: NA PERSIST: NO INSRVMOD: NO RANGE: NA DEFVALUE: NA UNITS: NA SPARSE: NO DESCR: NA"
],
null,
null,
null,
null
]
}