sfpDiagSupplyVoltage

1.3.6.1.4.1.637.61.1.56.5.1.9

Description

A column in the sfpDiagTable, containing the freshly-measured supply voltage of the specified SFP, encoded into a string. Three types of values are supported. In the following text, strings are enclosed in single quotes (a double quote marks the end of the DESCRIPTION field). 1. '0.00 VDC' to '6.55 VDC', in 0.01 VDC i…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.637.61.1.56.5.1 (sfpDiagEntry)
Node code
9
Node name
sfpDiagSupplyVoltage
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.637.61.1.56.5.1.9
URN notation
urn:oid:1.3.6.1.4.1.637.61.1.56.5.1.9
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 637 61 1 56 5 1 9}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) alcatel(637) asd(61) asam(1) sfpMIB(56) sfpDiagTable(5) sfpDiagEntry(1) sfpDiagSupplyVoltage(9)}
OID-IRI notation
  • /1/3/6/1/4/1/637/61/1/56/5/1/9
  • /ISO/Identified-Organization/6/1/4/1/637/61/1/56/5/1/9
  • /ISO/3/6/1/4/1/637/61/1/56/5/1/9
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/alcatel/61/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • /iso/identified-organization/dod/internet/private/enterprise/alcatel/asd/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • /iso/identified-organization/dod/internet/private/enterprises/alcatel/61/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • /iso/identified-organization/dod/internet/private/enterprises/alcatel/asd/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/alcatel/61/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/alcatel/asd/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • /iso/identified-organization/dod/internet/private/vendor-objects/alcatel/61/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • /iso/identified-organization/dod/internet/private/vendor-objects/alcatel/asd/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • /iso/org/dod/internet/private/enterprise/alcatel/61/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • /iso/org/dod/internet/private/enterprise/alcatel/asd/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • /iso/org/dod/internet/private/enterprises/alcatel/61/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • /iso/org/dod/internet/private/enterprises/alcatel/asd/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • /iso/org/dod/internet/private/ldap-enterprise/alcatel/61/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • /iso/org/dod/internet/private/ldap-enterprise/alcatel/asd/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • /iso/org/dod/internet/private/vendor-objects/alcatel/61/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • /iso/org/dod/internet/private/vendor-objects/alcatel/asd/asam/sfpMIB/sfpDiagTable/sfpDiagEntry/sfpDiagSupplyVoltage
  • Additional combinations skipped.

SNMP properties

Value type
DisplayString
Maximum access defined by MIB
read-only
Status in MIB
mandatory

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

sfpDiagSupplyVoltage OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
        "A column in the sfpDiagTable, containing the freshly-measured 
         supply voltage of the specified SFP, encoded into a string.

         Three types of values are supported.  In the following text, 
         strings are enclosed in single quotes (a double quote marks the 
         end of the DESCRIPTION field).  

         1.  '0.00 VDC' to '6.55 VDC', in 0.01 VDC increments.  Note that 
             ' VDC' is included in the string.

         2.  'Not Available'.  The measurement could not be obtained  
             (e.g. the specified SFP cage is empty).

         3.  'Invalid'. The supply voltage, in VDC, is negative (for example,
             due to incorrect external calibration constants in the SFP).  A
             negative VDC value is not valid in this context.

         The supply voltage can be retrieved from an electrical SFP, so 
         there is no need for a 'Not Applicable' string.

         ALCATEL NOTE:
             ACCESS: RO
             USAGE: NA
             PERSIST: NO 
             INSRVMOD: NO
             RANGE: NA
             DEFVALUE: NA
             UNITS: NA 
             SPARSE: NO
             DESCR: NA
        "
::= { sfpDiagEntry 9}

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

A column in the sfpDiagTable, containing the freshly-measured supply voltage of the specified SFP, encoded into a string. Three types of values are supported. In the following text, strings are enclosed in single quotes (a double quote marks the end of the DESCRIPTION field). 1. '0.00 VDC' to '6.55 VDC', in 0.01 VDC increments. Note that ' VDC' is included in the string. 2. 'Not Available'. The measurement could not be obtained (e.g. the specified SFP cage is empty). 3. 'Invalid'. The supply voltage, in VDC, is negative (for example, due to incorrect external calibration constants in the SFP). A negative VDC value is not valid in this context. The supply voltage can be retrieved from an electrical SFP, so there is no need for a 'Not Applicable' string. ALCATEL NOTE: ACCESS: RO USAGE: NA PERSIST: NO INSRVMOD: NO RANGE: NA DEFVALUE: NA UNITS: NA SPARSE: NO DESCR: NA

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Nokia networking MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Nokia networking MIB copies (LibreNMS/Observium Community)1 record · 3 sources

Description 1

sfpDiagSupplyVoltage · mandatoryMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Nokia networking MIB copies (LibreNMS/Observium Community)3 sources

Status in source: mandatory.

Names: sfpDiagSupplyVoltage

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "sfpDiagSupplyVoltage",
    "OBJECT-TYPE",
    "SYNTAX",
    "DisplayString",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"A column in the sfpDiagTable, containing the freshly-measured supply voltage of the specified SFP, encoded into a string. Three types of values are supported. In the following text, strings are enclosed in single quotes (a double quote marks the end of the DESCRIPTION field). 1. '0.00 VDC' to '6.55 VDC', in 0.01 VDC increments. Note that ' VDC' is included in the string. 2. 'Not Available'. The measurement could not be obtained (e.g. the specified SFP cage is empty). 3. 'Invalid'. The supply voltage, in VDC, is negative (for example, due to incorrect external calibration constants in the SFP). A negative VDC value is not valid in this context. The supply voltage can be retrieved from an electrical SFP, so there is no need for a 'Not Applicable' string. ALCATEL NOTE: ACCESS: RO USAGE: NA PERSIST: NO INSRVMOD: NO RANGE: NA DEFVALUE: NA UNITS: NA SPARSE: NO DESCR: NA \"",
    "::=",
    "{",
    "sfpDiagEntry",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "DisplayString"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "A column in the sfpDiagTable, containing the freshly-measured supply voltage of the specified SFP, encoded into a string. Three types of values are supported. In the following text, strings are enclosed in single quotes (a double quote marks the end of the DESCRIPTION field). 1. '0.00 VDC' to '6.55 VDC', in 0.01 VDC increments. Note that ' VDC' is included in the string. 2. 'Not Available'. The measurement could not be obtained (e.g. the specified SFP cage is empty). 3. 'Invalid'. The supply voltage, in VDC, is negative (for example, due to incorrect external calibration constants in the SFP). A negative VDC value is not valid in this context. The supply voltage can be retrieved from an electrical SFP, so there is no need for a 'Not Applicable' string. ALCATEL NOTE: ACCESS: RO USAGE: NA PERSIST: NO INSRVMOD: NO RANGE: NA DEFVALUE: NA UNITS: NA SPARSE: NO DESCR: NA"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.637)

Douglas E. Johnson

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.637)

Jean Rojnic

Siblings (52)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.637.61.1.56.5.1.1 sfpDiagLogicalSlot00
1.3.6.1.4.1.637.61.1.56.5.1.2 sfpDiagSfpFaceplateNumber00
1.3.6.1.4.1.637.61.1.56.5.1.3 sfpDiagAvailable00
1.3.6.1.4.1.637.61.1.56.5.1.4 sfpDiagLOS00
1.3.6.1.4.1.637.61.1.56.5.1.5 sfpDiagTxFault00
1.3.6.1.4.1.637.61.1.56.5.1.6 sfpDiagTxPower00
1.3.6.1.4.1.637.61.1.56.5.1.7 sfpDiagRxPower00
1.3.6.1.4.1.637.61.1.56.5.1.8 sfpDiagTxBiasCurrent00
1.3.6.1.4.1.637.61.1.56.5.1.10 sfpDiagTemperature00
1.3.6.1.4.1.637.61.1.56.5.1.11 sfpDiagTCAStatusTemperature00
1.3.6.1.4.1.637.61.1.56.5.1.12 sfpDiagTCAStatusVoltage00
1.3.6.1.4.1.637.61.1.56.5.1.13 sfpDiagTCAStatusBiasCurrent00
1.3.6.1.4.1.637.61.1.56.5.1.14 sfpDiagTCAStatusTxPower00
1.3.6.1.4.1.637.61.1.56.5.1.15 sfpDiagTCAStatusRxPower00
1.3.6.1.4.1.637.61.1.56.5.1.16 sfpDiagRSSIProfileId00
1.3.6.1.4.1.637.61.1.56.5.1.17 sfpDiagRSSIState00
1.3.6.1.4.1.637.61.1.56.5.1.18 sfpDiagRSSIRxPowerAlmLow00
1.3.6.1.4.1.637.61.1.56.5.1.19 sfpDiagRSSIRxPowerAlmHigh00
1.3.6.1.4.1.637.61.1.56.5.1.20 sfpDiagRSSIRxPowerWarnLow00
1.3.6.1.4.1.637.61.1.56.5.1.21 sfpDiagRSSIRxPowerWarnHigh00
1.3.6.1.4.1.637.61.1.56.5.1.22 sfpDiagRSSITxPowerAlmLow00
1.3.6.1.4.1.637.61.1.56.5.1.23 sfpDiagRSSITxPowerAlmHigh00
1.3.6.1.4.1.637.61.1.56.5.1.24 sfpDiagRSSITxPowerWarnLow00
1.3.6.1.4.1.637.61.1.56.5.1.25 sfpDiagRSSITxPowerWarnHigh00
1.3.6.1.4.1.637.61.1.56.5.1.26 sfpDiagRSSITemperatureAlmLow00
1.3.6.1.4.1.637.61.1.56.5.1.27 sfpDiagRSSITemperatureAlmHigh00
1.3.6.1.4.1.637.61.1.56.5.1.28 sfpDiagRSSITemperatureWarnLow00
1.3.6.1.4.1.637.61.1.56.5.1.29 sfpDiagRSSITemperatureWarnHigh00
1.3.6.1.4.1.637.61.1.56.5.1.30 sfpDiagRSSIBiasAlmLow00
1.3.6.1.4.1.637.61.1.56.5.1.31 sfpDiagRSSIBiasAlmHigh00
1.3.6.1.4.1.637.61.1.56.5.1.32 sfpDiagRSSIBiasWarnLow00
1.3.6.1.4.1.637.61.1.56.5.1.33 sfpDiagRSSIBiasWarnHigh00
1.3.6.1.4.1.637.61.1.56.5.1.34 sfpDiagRSSIVoltageAlmLow00
1.3.6.1.4.1.637.61.1.56.5.1.35 sfpDiagRSSIVoltageAlmHigh00
1.3.6.1.4.1.637.61.1.56.5.1.36 sfpDiagRSSIVoltageWarnLow00
1.3.6.1.4.1.637.61.1.56.5.1.37 sfpDiagRSSIVoltageWarnHigh00
1.3.6.1.4.1.637.61.1.56.5.1.38 sfpDiagRSSIExtRxPowerAlmLow00
1.3.6.1.4.1.637.61.1.56.5.1.39 sfpDiagRSSIExtRxPowerAlmHigh00
1.3.6.1.4.1.637.61.1.56.5.1.40 sfpDiagRSSIExtRxPowerWarnLow00
1.3.6.1.4.1.637.61.1.56.5.1.41 sfpDiagRSSIExtRxPowerWarnHigh00
1.3.6.1.4.1.637.61.1.56.5.1.42 sfpDiagRSSIExtTxPowerAlmLow00
1.3.6.1.4.1.637.61.1.56.5.1.43 sfpDiagRSSIExtTxPowerAlmHigh00
1.3.6.1.4.1.637.61.1.56.5.1.44 sfpDiagRSSIExtTxPowerWarnLow00
1.3.6.1.4.1.637.61.1.56.5.1.45 sfpDiagRSSIExtTxPowerWarnHigh00
1.3.6.1.4.1.637.61.1.56.5.1.46 sfpDiagRSSIExtBiasAlmLow00
1.3.6.1.4.1.637.61.1.56.5.1.47 sfpDiagRSSIExtBiasAlmHigh00
1.3.6.1.4.1.637.61.1.56.5.1.48 sfpDiagRSSIExtBiasWarnLow00
1.3.6.1.4.1.637.61.1.56.5.1.49 sfpDiagRSSIExtBiasWarnHigh00
1.3.6.1.4.1.637.61.1.56.5.1.50 sfpDiagRSSIExtTemperatureAlmLow00
1.3.6.1.4.1.637.61.1.56.5.1.51 sfpDiagRSSIExtTemperatureAlmHigh00