The value of tmnxOamEthCfmPingCtlSrcMaName specifies the name of the Maintenance Association (MA) to be used by the test. The source association can be specified using tmnxOamEthCfmPingCtlSrcMaName or tmnxOamEthCfmPingCtlSrcMaIndex (not both). tmnxOamEthCfmPingCtlSrcMaName is the preferred object for specifying the source association. One of tmnxOamEthCfmPingCtlSrcMaName and tmnxOamEthCfmPingCtlSrcMaIndex should be assigned a non-default value. Otherwise, an attempt to start the test will fail. If specified, tmnxOamEthCfmPingCtlSrcMaName should match a name configured using TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMaMgmtAdminName. Otherwise, the test will fail. An empty string indicates a name has not been configured.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Nokia networking MIB copies (LibreNMS/Observium Community)