Description 1
The number of LLDPDU Length Errors recorded for the Port.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Nokia networking MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.6527.3.1.2.59.2.1.1.3
The number of LLDPDU Length Errors recorded for the Port.
Identification
{1 3 6 1 4 1 6527 3 1 2 59 2 1 1 3}
A counter is cumulative. To estimate a rate, subtract two readings and divide by the elapsed time; use the units stated in the MIB.
Counter values can wrap or reset. A decrease alone does not distinguish a wrap from a reset, and multiple wraps between readings cannot be recovered reliably. Check the device's discontinuity indicators when available.
Published counter width: 32 bits. SMIv2: Counter32 · Counter64
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: ifIndex, tmnxLldpStatsTxDestMACAddress.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.6527.3.1.2.59.2.1.1.3
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
tmnxLldpStatsTxLLDPDULengthErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of LLDPDU Length Errors recorded for the Port."
REFERENCE
"IEEE Std 802.1AB-200X 10.2.7.2"
::= { tmnxLldpStatsTxPortEntry 3 }tmnxLldpStatsTxLLDPDULengthErrs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of LLDPD Length Errors recorded for the Port."
REFERENCE
"IEEE Std 802.1AB-200X 10.2.7.2"
::= { tmnxLldpStatsTxPortEntry 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
The number of LLDPDU Length Errors recorded for the Port.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Nokia networking MIB copies (LibreNMS/Observium Community)
Description 2
The number of LLDPD Length Errors recorded for the Port.
Netdisco MIB archive copiesNokia networking MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: tmnxLldpStatsTxLLDPDULengthErrs
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tmnxLldpStatsTxLLDPDULengthErrs",
"OBJECT-TYPE",
"SYNTAX",
"Counter32",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The number of LLDPDU Length Errors recorded for the Port.\"",
"REFERENCE",
"\"IEEE Std 802.1AB-200X 10.2.7.2\"",
"::=",
"{",
"tmnxLldpStatsTxPortEntry",
"3",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Counter32"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The number of LLDPDU Length Errors recorded for the Port."
],
[
"REFERENCE",
"IEEE Std 802.1AB-200X 10.2.7.2"
],
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. Nokia support.
Module: TIMETRA-LLDP-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'LLDP-MIB': ['LldpChassisId', 'LldpChassisIdSubtype', 'LldpManAddrIfSubtype', 'LldpManAddress', 'LldpPortId', 'LldpPortIdSubtype', 'LldpSystemCapabilitiesMap'], 'RMON2-MIB': ['TimeFilter', 'ZeroBasedCounter32'], 'SNMPv2-TC': ['MacAddress', 'TEXTUAL-CONVENTION', 'TruthValue'], 'SNMPv2-SMI': ['Counter32', 'Counter64', 'Integer32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'TIMETRA-TC-MIB': ['TmnxEnabledDisabled', 'TmnxEnabledDisabledAdminState', 'TmnxLldpManAddressIndex', 'TmnxPortID'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'TIMETRA-GLOBAL-MIB': ['timetraSRMIBModules', 'tmnxSRConfs', 'tmnxSRNotifyPrefix', 'tmnxSRObjs'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Related source files and packages:
Vendor MIB copy from the LibreNMS archive.
Module: TIMETRA-LLDP-MIB
{'IF-MIB': ['ifIndex'], 'LLDP-MIB': ['LldpChassisId', 'LldpChassisIdSubtype', 'LldpManAddrIfSubtype', 'LldpManAddress', 'LldpPortId', 'LldpPortIdSubtype', 'LldpSystemCapabilitiesMap'], 'RMON2-MIB': ['TimeFilter', 'ZeroBasedCounter32'], 'SNMPv2-TC': ['MacAddress', 'TEXTUAL-CONVENTION', 'TruthValue'], 'SNMPv2-SMI': ['Counter32', 'Counter64', 'Integer32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'TIMETRA-TC-MIB': ['TmnxEnabledDisabled', 'TmnxEnabledDisabledAdminState', 'TmnxLldpManAddressIndex', 'TmnxPortID'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'TIMETRA-GLOBAL-MIB': ['timetraSRMIBModules', 'tmnxSRConfs', 'tmnxSRNotifyPrefix', 'tmnxSRObjs'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Status in source: current.
Names: tmnxLldpStatsTxLLDPDULengthErrs
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tmnxLldpStatsTxLLDPDULengthErrs",
"OBJECT-TYPE",
"SYNTAX",
"Counter32",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The number of LLDPD Length Errors recorded for the Port.\"",
"REFERENCE",
"\"IEEE Std 802.1AB-200X 10.2.7.2\"",
"::=",
"{",
"tmnxLldpStatsTxPortEntry",
"3",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Counter32"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The number of LLDPD Length Errors recorded for the Port."
],
[
"REFERENCE",
"IEEE Std 802.1AB-200X 10.2.7.2"
],
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. Nokia support.
Module: TIMETRA-LLDP-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'LLDP-MIB': ['LldpChassisId', 'LldpChassisIdSubtype', 'LldpManAddrIfSubtype', 'LldpManAddress', 'LldpPortId', 'LldpPortIdSubtype', 'LldpSystemCapabilitiesMap'], 'RMON2-MIB': ['TimeFilter', 'ZeroBasedCounter32'], 'SNMPv2-TC': ['MacAddress', 'TEXTUAL-CONVENTION', 'TruthValue'], 'SNMPv2-SMI': ['Counter32', 'Counter64', 'Integer32', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'TIMETRA-TC-MIB': ['TmnxEnabledDisabled', 'TmnxEnabledDisabledAdminState'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'TIMETRA-GLOBAL-MIB': ['timetraSRMIBModules', 'tmnxSRConfs', 'tmnxSRNotifyPrefix', 'tmnxSRObjs'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Related source files and packages:
Vendor MIB copy from the Netdisco archive.
Module: TIMETRA-LLDP-MIB
Same published definition (formatting differs; exact original is in the source file)
{'IF-MIB': ['ifIndex'], 'LLDP-MIB': ['LldpChassisId', 'LldpChassisIdSubtype', 'LldpManAddrIfSubtype', 'LldpManAddress', 'LldpPortId', 'LldpPortIdSubtype', 'LldpSystemCapabilitiesMap', 'lldpLocManAddr', 'lldpLocManAddrSubtype'], 'RMON2-MIB': ['TimeFilter', 'ZeroBasedCounter32'], 'SNMPv2-TC': ['MacAddress', 'TEXTUAL-CONVENTION', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'TIMETRA-TC-MIB': ['TmnxEnabledDisabled'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'TIMETRA-GLOBAL-MIB': ['timetraSRMIBModules', 'tmnxSRConfs', 'tmnxSRNotifyPrefix', 'tmnxSRObjs'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6527.3.1.2.59.2.1.1.1 | tmnxLldpStatsTxDestMACAddress | 0 | 0 | |
| 1.3.6.1.4.1.6527.3.1.2.59.2.1.1.2 | tmnxLldpStatsTxPortFrames | 0 | 0 |