Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"aluExtPortEtherAdminPhyTxClock",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"notApplicable",
"(",
"0",
")",
",",
"slave",
"(",
"1",
")",
",",
"master",
"(",
"2",
")",
",",
"auto-pref-slave",
"(",
"3",
")",
",",
"auto-pref-master",
"(",
"4",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of aluExtPortEtherAdminPhyTxClock indicates the mode used to establish timing control of a 1000BASE-T port. The aluExtPortEtherAdminPhyTxClock is used to control the setting of register 9, bits 10-12 that are described in Table 40-3 of IEEE 802.3-2008. Register 9.12, the MASTER-SLAVE Manual Config Enable bit, is cleared when 'auto-pref-slave (3)' or 'auto-pref-master (4)' is configured. Otherwise the register 9.12 bit is set. Register 9.10 will be cleared when 'auto-pref-slave (3)' is configured and 'auto-pref-master (4)' will cause register 9.10 to be cleared. When aluExtPortEtherAdminPhyTxClock is 'slave (1)', register 9.11, the MASTER-SLAVE Manual Config Value bit, is cleared. When aluExtPortEtherAdminPhyTxClock is 'master (2)' MASTER-SLAVE Manual Config Value bit is set. For ports that cannot support 1000BASE-T, aluExtPortEtherAdminPhyTxClock will be defaulted to 'notApplicable (0)' and cannot be changed. For ports that support 1000BASE-T, setting aluExtPortEtherAdminPhyTxClock to 'notApplicable (0)' will result in aluExtPortEtherAdminPhyTxClock being set to the DEFVAL value of 'auto-pref-slave (3)'. Setting aluExtPortEtherAdminPhyTxClock on 1000BaseT microwave aware ports (ie. ports associated with ALU-MICROWAVE-PORT::aluMwRadioPortID) is allowed but it does not establish timing control of the 1000BASE-T port. The operational aspects of microwave ports with respect to timing control is described under aluExtPortEtherOperPhyTxClock\"",
"REFERENCE",
"\"IEEE Std 802.3-2008 Section 40.5\"",
"DEFVAL",
"{",
"auto-pref-slave",
"}",
"::=",
"{",
"aluExtTmnxPortEtherEntry",
"11",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"notApplicable",
0
],
[
"slave",
1
],
[
"master",
2
],
[
"auto-pref-slave",
3
],
[
"auto-pref-master",
4
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of aluExtPortEtherAdminPhyTxClock indicates the mode used to establish timing control of a 1000BASE-T port. The aluExtPortEtherAdminPhyTxClock is used to control the setting of register 9, bits 10-12 that are described in Table 40-3 of IEEE 802.3-2008. Register 9.12, the MASTER-SLAVE Manual Config Enable bit, is cleared when 'auto-pref-slave (3)' or 'auto-pref-master (4)' is configured. Otherwise the register 9.12 bit is set. Register 9.10 will be cleared when 'auto-pref-slave (3)' is configured and 'auto-pref-master (4)' will cause register 9.10 to be cleared. When aluExtPortEtherAdminPhyTxClock is 'slave (1)', register 9.11, the MASTER-SLAVE Manual Config Value bit, is cleared. When aluExtPortEtherAdminPhyTxClock is 'master (2)' MASTER-SLAVE Manual Config Value bit is set. For ports that cannot support 1000BASE-T, aluExtPortEtherAdminPhyTxClock will be defaulted to 'notApplicable (0)' and cannot be changed. For ports that support 1000BASE-T, setting aluExtPortEtherAdminPhyTxClock to 'notApplicable (0)' will result in aluExtPortEtherAdminPhyTxClock being set to the DEFVAL value of 'auto-pref-slave (3)'. Setting aluExtPortEtherAdminPhyTxClock on 1000BaseT microwave aware ports (ie. ports associated with ALU-MICROWAVE-PORT::aluMwRadioPortID) is allowed but it does not establish timing control of the 1000BASE-T port. The operational aspects of microwave ports with respect to timing control is described under aluExtPortEtherOperPhyTxClock"
],
[
"REFERENCE",
"IEEE Std 802.3-2008 Section 40.5"
],
null,
null,
[
"DEFVAL",
"auto-pref-slave"
]
]
}