The amount of delay, measured in seconds, between when power is provided to the Rack PDU and when the Rack PDU provides basic master power to the outlets.
Sources for this description
Dell MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.674.10903.200.2.200.110.3.1.4
The amount of delay, measured in seconds, between when power is provided to the Rack PDU and when the Rack PDU provides basic master power to the outlets.
Identification
{1 3 6 1 4 1 674 10903 200 2 200 110 3 1 4}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In DellrPDU-MIB, the row index rPDUDeviceConfigIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.674.10903.200.2.200.110.3.1.4.<rPDUDeviceConfigIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.674.10903.200.2.200.110.3.1.4
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rPDUDeviceConfigColdstartDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of delay, measured in seconds, between when power is
provided to the Rack PDU and when the Rack PDU provides basic
master power to the outlets."
::= { rPDUDeviceConfigEntry 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The amount of delay, measured in seconds, between when power is provided to the Rack PDU and when the Rack PDU provides basic master power to the outlets.
Dell MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: rPDUDeviceConfigColdstartDelay
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rPDUDeviceConfigColdstartDelay",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The amount of delay, measured in seconds, between when power is provided to the Rack PDU and when the Rack PDU provides basic master power to the outlets.\"",
"::=",
"{",
"rPDUDeviceConfigEntry",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The amount of delay, measured in seconds, between when power is provided to the Rack PDU and when the Rack PDU provides basic master power to the outlets."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. Dell support.
Module: DellrPDU-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}Related source files and packages:
Same file in Observium Community.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.1 | rPDUDeviceConfigIndex | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.2 | rPDUDeviceConfigName | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.3 | rPDUDeviceConfigLocation | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.5 | rPDUDeviceCfgLowLoadPwrThresh | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.6 | rPDUDeviceCfgNerOvloadPwrThresh | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.7 | rPDUDeviceCfgOverloadPwrThresh | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.8 | rPDUDeviceConfigPowerHeadroom | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.9 | rPDUDeviceConfigPeakPower | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.10 | rPDUDeviceCfgPeakPwrStartTime | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.11 | rPDUDeviceConfigPeakPwrCapTime | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.12 | rPDUDeviceCfgPeakPowerHeadroom | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.13 | rPDUDeviceCfgEnergyStartTime | 0 | 0 |