The highest input power level recorded by the connected devices in hundredths of kilowatt-hours.
Sources for this description
Dell MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.674.10903.200.2.200.110.3.1.9
The highest input power level recorded by the connected devices in hundredths of kilowatt-hours.
Identification
{1 3 6 1 4 1 674 10903 200 2 200 110 3 1 9}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In DellrPDU-MIB, the row index rPDUDeviceConfigIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.674.10903.200.2.200.110.3.1.9.<rPDUDeviceConfigIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.674.10903.200.2.200.110.3.1.9
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rPDUDeviceConfigPeakPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The highest input power level recorded by the connected
devices in hundredths of kilowatt-hours."
::= { rPDUDeviceConfigEntry 9 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The highest input power level recorded by the connected devices in hundredths of kilowatt-hours.
Dell MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: mandatory.
Names: rPDUDeviceConfigPeakPower
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rPDUDeviceConfigPeakPower",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"ACCESS",
"read-only",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The highest input power level recorded by the connected devices in hundredths of kilowatt-hours.\"",
"::=",
"{",
"rPDUDeviceConfigEntry",
"9",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The highest input power level recorded by the connected devices in hundredths of kilowatt-hours."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive. Dell support.
Module: DellrPDU-MIB
See published definition above
{'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['enterprises', 'IpAddress', 'Gauge', 'TimeTicks'], 'RFC1213-MIB': ['DisplayString']}Related source files and packages:
Same file in Observium Community.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.1 | rPDUDeviceConfigIndex | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.2 | rPDUDeviceConfigName | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.3 | rPDUDeviceConfigLocation | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.4 | rPDUDeviceConfigColdstartDelay | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.5 | rPDUDeviceCfgLowLoadPwrThresh | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.6 | rPDUDeviceCfgNerOvloadPwrThresh | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.7 | rPDUDeviceCfgOverloadPwrThresh | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.8 | rPDUDeviceConfigPowerHeadroom | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.10 | rPDUDeviceCfgPeakPwrStartTime | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.11 | rPDUDeviceConfigPeakPwrCapTime | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.12 | rPDUDeviceCfgPeakPowerHeadroom | 0 | 0 | |
| 1.3.6.1.4.1.674.10903.200.2.200.110.3.1.13 | rPDUDeviceCfgEnergyStartTime | 0 | 0 |