Status in source: obsolete.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"configL2IfaceDuplexSpeedSet",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"autonegotiate",
"(",
"1",
")",
",",
"half-10",
"(",
"2",
")",
",",
"full-10",
"(",
"3",
")",
",",
"half-100",
"(",
"4",
")",
",",
"full-100",
"(",
"5",
")",
",",
"half-1000",
"(",
"6",
")",
",",
"full-1000",
"(",
"7",
")",
",",
"pos-155",
"(",
"8",
")",
",",
"pos-622",
"(",
"9",
")",
",",
"full-10000",
"(",
"10",
")",
",",
"half-auto",
"(",
"11",
")",
",",
"full-auto",
"(",
"12",
")",
",",
"auto-10",
"(",
"13",
")",
",",
"auto-100",
"(",
"14",
")",
",",
"auto-1000",
"(",
"16",
")",
",",
"illegal",
"(",
"99",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"obsolete",
"DESCRIPTION",
"\"The desired speed and duplex mode for the interface. If the selected control is not available for the interface, a value of illegal (99) is returned. If the port type does NOT support the default of autonegotiate (1), then the application will initialize the port to a valid value (e.g., 1000full (6)). Note that not all controls are available for all interfaces. For example, only full-1000 (6) is available for Gigabit Ethernet interfaces. As this object was marked as obsolete the following two configurable parameters of an interface should be used: configL2IfaceDuplexModeSet, configL2IfaceSpeedSet \"",
"::=",
"{",
"configL2IfaceEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"autonegotiate",
1
],
[
"half-10",
2
],
[
"full-10",
3
],
[
"half-100",
4
],
[
"full-100",
5
],
[
"half-1000",
6
],
[
"full-1000",
7
],
[
"pos-155",
8
],
[
"pos-622",
9
],
[
"full-10000",
10
],
[
"half-auto",
11
],
[
"full-auto",
12
],
[
"auto-10",
13
],
[
"auto-100",
14
],
[
"auto-1000",
16
],
[
"illegal",
99
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"obsolete"
],
[
"DESCRIPTION",
"The desired speed and duplex mode for the interface. If the selected control is not available for the interface, a value of illegal (99) is returned. If the port type does NOT support the default of autonegotiate (1), then the application will initialize the port to a valid value (e.g., 1000full (6)). Note that not all controls are available for all interfaces. For example, only full-1000 (6) is available for Gigabit Ethernet interfaces. As this object was marked as obsolete the following two configurable parameters of an interface should be used: configL2IfaceDuplexModeSet, configL2IfaceSpeedSet"
],
null,
null,
null,
null
]
}