Status in source: current.
Technical details
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"mplsTeModuleReadOnlyCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"Compliance requirement for implementations that only provide read-only support for MPLS-TE-STD-MIB. Such devices can then be monitored but cannot be configured using this MIB modules.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"mplsTunnelGroup",
",",
"mplsTunnelScalarGroup",
"}",
"GROUP",
"mplsTunnelManualGroup",
"DESCRIPTION",
"\"This group is mandatory for devices which support manual configuration of tunnels.\"",
"GROUP",
"mplsTunnelSignaledGroup",
"DESCRIPTION",
"\"This group is mandatory for devices which support signaled tunnel set up.\"",
"GROUP",
"mplsTunnelIsNotIntfcGroup",
"DESCRIPTION",
"\"This group is mandatory for devices which support tunnels that are not interfaces.\"",
"GROUP",
"mplsTunnelIsIntfcGroup",
"DESCRIPTION",
"\"This group is mandatory for devices which support tunnels that are interfaces.\"",
"GROUP",
"mplsTunnelCRLDPResOptionalGroup",
"DESCRIPTION",
"\"Objects in this group are required by implementations supporting the CR-LDP protocol for signalling of TE tunnels.\"",
"GROUP",
"mplsTeNotificationGroup",
"DESCRIPTION",
"\"This group is mandatory for those implementations which can implement the notifications contained in this group.\"",
"OBJECT",
"mplsTunnelName",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelDescr",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelIsIf",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelIfIndex",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelXCPointer",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelSignallingProto",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelSetupPrio",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelHoldingPrio",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelSessionAttributes",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelLocalProtectInUse",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelResourcePointer",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelInstancePriority",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelHopTableIndex",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelIncludeAnyAffinity",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelIncludeAllAffinity",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelExcludeAnyAffinity",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelPathInUse",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelRole",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelAdminStatus",
"SYNTAX",
"INTEGER",
"{",
"up",
"(",
"1",
")",
",",
"down",
"(",
"2",
")",
"}",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Only up and down states must be supported. Write access is not required.\"",
"OBJECT",
"mplsTunnelRowStatus",
"SYNTAX",
"RowStatus",
"{",
"active",
"(",
"1",
")",
"}",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelHopAddrType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelHopIpAddr",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelHopIpPrefixLen",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelHopAddrUnnum",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelHopAsNumber",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelHopLspId",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelHopType",
"SYNTAX",
"INTEGER",
"{",
"strict",
"(",
"1",
")",
"}",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"loose(2) need not be supported. Write access is not required.\"",
"OBJECT",
"mplsTunnelHopInclude",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelHopPathOptionName",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelHopEntryPathComp",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelHopRowStatus",
"SYNTAX",
"RowStatus",
"{",
"active",
"(",
"1",
")",
"}",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelHopStorageType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelResourceMaxRate",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelResourceMeanRate",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelResourceMaxBurstSize",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelResourceMeanBurstSize",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelResourceExBurstSize",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelResourceFrequency",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelResourceWeight",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelResourceRowStatus",
"SYNTAX",
"RowStatus",
"{",
"active",
"(",
"1",
")",
"}",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelResourceStorageType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelCRLDPResMeanBurstSize",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelCRLDPResExBurstSize",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelCRLDPResFrequency",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelCRLDPResWeight",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelCRLDPResFlags",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelCRLDPResRowStatus",
"SYNTAX",
"RowStatus",
"{",
"active",
"(",
"1",
")",
"}",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"mplsTunnelCRLDPResStorageType",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"::=",
"{",
"mplsTeCompliances",
"2",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"Compliance requirement for implementations that only provide read-only support for MPLS-TE-STD-MIB. Such devices can then be monitored but cannot be configured using this MIB modules."
],
null,
[
"ComplianceModules",
[
[
null,
[
"mplsTunnelGroup",
"mplsTunnelScalarGroup",
"mplsTunnelManualGroup",
"mplsTunnelSignaledGroup",
"mplsTunnelIsNotIntfcGroup",
"mplsTunnelIsIntfcGroup",
"mplsTunnelCRLDPResOptionalGroup",
"mplsTeNotificationGroup"
]
]
]
]
]
}