Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tnAmplifierPortPowerGain",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"UNITS",
[
"literal",
"226d4222"
],
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The following description applies to the signal port of the amplifier card: Current configurable ranges and defaults: A2325A: (1600..3200), 1600 A2P2125 (port 1): ( 200..2000), 1000 A2P2125 (port 4): (1500..3100), 1500 A4PSWG (port 1): ( 700..2900), 700 A4PSWG (port 4): ( 200..2000), 1000 AA2DONW: (1300..2300), 1300 AAR_8A: (1000..2000), 1500 AHPHG: (1300..3300), 1300 AHPLG: ( 600..2400), 600 ALPFGK: (1300..2300), 1800 ALPFGT: (1300..2300), 1800 ALPHG: (1000..3000), 1000 AM2017B: ( 600..2400), 600 AM2032A: (2600..4000), 2600 AM2125A: (1500..3100), 1500 AM2125B: (1500..3100), 1500 AM2318A: ( 700..2400), 700 AM2325B: (1600..3200), 1600 AM2625A: (1600..3000), 1600 ASWG: ( 700..2900), 700 MESH4: ( 700..2400), 700 RA2P: ( 200..2000), 1000.\"",
"::=",
"{",
"tnAmplifierPortConfigEntry",
"1",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
[
"UNITS",
"mB"
],
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The following description applies to the signal port of the amplifier card: Current configurable ranges and defaults: A2325A: (1600..3200), 1600 A2P2125 (port 1): ( 200..2000), 1000 A2P2125 (port 4): (1500..3100), 1500 A4PSWG (port 1): ( 700..2900), 700 A4PSWG (port 4): ( 200..2000), 1000 AA2DONW: (1300..2300), 1300 AAR_8A: (1000..2000), 1500 AHPHG: (1300..3300), 1300 AHPLG: ( 600..2400), 600 ALPFGK: (1300..2300), 1800 ALPFGT: (1300..2300), 1800 ALPHG: (1000..3000), 1000 AM2017B: ( 600..2400), 600 AM2032A: (2600..4000), 2600 AM2125A: (1500..3100), 1500 AM2125B: (1500..3100), 1500 AM2318A: ( 700..2400), 700 AM2325B: (1600..3200), 1600 AM2625A: (1600..3000), 1600 ASWG: ( 700..2900), 700 MESH4: ( 700..2400), 700 RA2P: ( 200..2000), 1000."
],
null,
null,
null,
null
]
}