Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tnOamPingCtlProbeCount",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"1",
".",
".",
"100000",
")",
"UNITS",
[
"literal",
"2270726f62657322"
],
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of tnOamPingCtlProbeCount specifies the number of probes to send during the test. The maximum probe count depends on the value of tnOamPingCtlTestMode, as follows: 'macPopulate', 'macPurge','p2mpLspPing', 'svcPing' : 1 'ethCfmTwoWayDelay', 'ethCfmOneWayDelay', 'ethCfmTwoWaySlm', 'ethCfmTwoWayLm' : 1000 'icmpPing' : 100000 otherwise : 100 For the following tnOamPingCtlTestMode values, the value of tnOamPingCtlProbeCount does not affect the behavior of the test: 'mrInfo', 'mtuPing'. If tnOamPingCtlTestMode is 'icmpPing', the default probe count value is 5. Otherwise, the DEFVAL applies.\"",
"DEFVAL",
"{",
"1",
"}",
"::=",
"{",
"tnOamPingCtlEntry",
"20",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
1,
100000
]
]
]
],
[
"UNITS",
"probes"
],
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of tnOamPingCtlProbeCount specifies the number of probes to send during the test. The maximum probe count depends on the value of tnOamPingCtlTestMode, as follows: 'macPopulate', 'macPurge','p2mpLspPing', 'svcPing' : 1 'ethCfmTwoWayDelay', 'ethCfmOneWayDelay', 'ethCfmTwoWaySlm', 'ethCfmTwoWayLm' : 1000 'icmpPing' : 100000 otherwise : 100 For the following tnOamPingCtlTestMode values, the value of tnOamPingCtlProbeCount does not affect the behavior of the test: 'mrInfo', 'mtuPing'. If tnOamPingCtlTestMode is 'icmpPing', the default probe count value is 5. Otherwise, the DEFVAL applies."
],
null,
null,
null,
[
"DEFVAL",
1
]
]
}