Status in source: current.
Names: tnPortHoldTimeUp
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tnPortHoldTimeUp",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"90000",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The value of tnPortHoldTimeUp is used to configure the hold-timer for link up event dampening. This guards against reporting excessive interface transitions. This is implemented by not advertising subsequent transitions of the interface to upper layer protocols until the configured timer has expired. A value of zero (0) indicates that an up transition is reported immediately. The value of tnPortHoldTimeUp is not applicable when tnPortClass has a value of 'sonet (5)'. In that case, tnSonetHoldTimeUp is used instead. tnPortHoldTimeUp is measured in units as specified by tnPortHoldTimeUnits. The maximum hold-time for this object is 15 minutes, regardless of the units specified. Attempts to change the maximum value to a hold-time longer than 15 minutes will result in an INCONSISTENT error.\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"tnPortEntry",
"14",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
0,
90000
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The value of tnPortHoldTimeUp is used to configure the hold-timer for link up event dampening. This guards against reporting excessive interface transitions. This is implemented by not advertising subsequent transitions of the interface to upper layer protocols until the configured timer has expired. A value of zero (0) indicates that an up transition is reported immediately. The value of tnPortHoldTimeUp is not applicable when tnPortClass has a value of 'sonet (5)'. In that case, tnSonetHoldTimeUp is used instead. tnPortHoldTimeUp is measured in units as specified by tnPortHoldTimeUnits. The maximum hold-time for this object is 15 minutes, regardless of the units specified. Attempts to change the maximum value to a hold-time longer than 15 minutes will result in an INCONSISTENT error."
],
null,
null,
null,
[
"DEFVAL",
0
]
]
}
- Nokia networking MIB copies (LibreNMS/Observium Community)
· Publisher's source file: TN-PORT-MIB
Vendor MIB copy from the LibreNMS archive.
Nokia support.
Module: TN-PORT-MIB
See published definition above
Module imports
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DateAndTime', 'RowStatus', 'TimeStamp', 'TruthValue', 'MacAddress', 'RowPointer'], 'TN-TC-MIB': ['TmnxActionType', 'TmnxPortID', 'TNamedItemOrEmpty', 'TNamedItem', 'TItemLongDescription', 'TmnxEnabledDisabled'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter32', 'Counter64', 'Integer32'], 'TROPIC-GLOBAL-REG': ['tnSRMIBModules', 'tnSRNotifyPrefix', 'tnSRObjs'], 'TROPIC-SYSTEM-MIB': ['tnSysSwitchId']}
· Download TN-PORT-MIB
Related source files and packages:
- Nokia networking MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
Nokia support.
Module: TN-PORT-MIB
Same published definition
Module imports
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DateAndTime', 'RowStatus', 'TimeStamp', 'TruthValue', 'MacAddress', 'RowPointer'], 'TN-TC-MIB': ['TmnxActionType', 'TmnxPortID', 'TNamedItemOrEmpty', 'TNamedItem', 'TItemLongDescription', 'TmnxEnabledDisabled'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter32', 'Counter64', 'Integer32'], 'TROPIC-GLOBAL-REG': ['tnSRMIBModules', 'tnSRNotifyPrefix', 'tnSRObjs'], 'TROPIC-SYSTEM-MIB': ['tnSysSwitchId']}
· Download TN-PORT-MIB