Status in source: unspecified.
Technical details
{
"smi_kind": "MODULE-IDENTITY",
"definition": [
"lumOcmMIBModule",
"MODULE-IDENTITY",
"LAST-UPDATED",
[
"literal",
"223230313830363135303030305a22"
],
"ORGANIZATION",
"\"Infinera Corporation\"",
"CONTACT-INFO",
"\"techsupport@infinera.com\"",
"DESCRIPTION",
"\"The optical control interface MIB. - General - Monitor interfaces Note that, every time a get operation is performed and both ports are set to admin status up, the switch will switch to update both ports. (unless commissioning mode) The guaranteed durability of switching is 10 million times. That means, if you switch (perform a get operation) more than every 50 second, product lifetime of 15 years can not be guaranteed. \"",
"REVISION",
[
"literal",
"223230313830363135303030305a22"
],
"DESCRIPTION",
"\" Changes made for release r31.0: - Added ocmIfSpacingMode and ocmIfHighInputPower in ocmIfEntry.\"",
"REVISION",
[
"literal",
"223230313731323135303030305a22"
],
"DESCRIPTION",
"\" Changes made for release r30.0: - Added ocmChannelReferenceTime and ocmChannelSaveReference action in ocmChannel.\"",
"REVISION",
[
"literal",
"223230313730363135303030305a22"
],
"DESCRIPTION",
"\"Changes made for release r29.0: - Changed ORGANIZATION and CONTACT-INFO\"",
"REVISION",
[
"literal",
"223230313630313131303030305a22"
],
"DESCRIPTION",
"\"Added default value notPresent for operStatus.\"",
"REVISION",
[
"literal",
"223230313430353136303030305a22"
],
"DESCRIPTION",
"\"Added a parameter for offset adjustment which will allow for better regulation in the optical control loop\"",
"REVISION",
[
"literal",
"223230303830313136303030305a22"
],
"DESCRIPTION",
"\"First version.\"",
"::=",
"{",
"lumModules",
"33",
"}"
],
"syntax_tree": [
[
"LAST-UPDATED",
"201806150000Z"
],
[
"ORGANIZATION",
"Infinera Corporation"
],
[
"CONTACT-INFO",
"techsupport@infinera.com"
],
[
"DESCRIPTION",
"The optical control interface MIB. - General - Monitor interfaces Note that, every time a get operation is performed and both ports are set to admin status up, the switch will switch to update both ports. (unless commissioning mode) The guaranteed durability of switching is 10 million times. That means, if you switch (perform a get operation) more than every 50 second, product lifetime of 15 years can not be guaranteed."
],
[
"Revisions",
[
[
"201806150000Z",
[
"DESCRIPTION",
"Changes made for release r31.0: - Added ocmIfSpacingMode and ocmIfHighInputPower in ocmIfEntry."
]
],
[
"201712150000Z",
[
"DESCRIPTION",
"Changes made for release r30.0: - Added ocmChannelReferenceTime and ocmChannelSaveReference action in ocmChannel."
]
],
[
"201706150000Z",
[
"DESCRIPTION",
"Changes made for release r29.0: - Changed ORGANIZATION and CONTACT-INFO"
]
],
[
"201601110000Z",
[
"DESCRIPTION",
"Added default value notPresent for operStatus."
]
],
[
"201405160000Z",
[
"DESCRIPTION",
"Added a parameter for offset adjustment which will allow for better regulation in the optical control loop"
]
],
[
"200801160000Z",
[
"DESCRIPTION",
"First version."
]
]
]
]
]
}