OID reference

invPhysParentRelPos

1.3.6.1.4.1.8708.2.3.2.1.1.1.6

Description

An indication of the relative position of this 'child' component among all its 'sibling' components. Sibling components are defined as invPhysEntries which share the same instance values of each of the invPhysContainedIn and invPhysClass objects. An NMS can use this object to identify the relative ordering for all sib…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.8708.2.3.2.1.1.1 (invPhysEntry)
Node code
6
Node name
invPhysParentRelPos
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.8708.2.3.2.1.1.1.6
URN notation
urn:oid:1.3.6.1.4.1.8708.2.3.2.1.1.1.6
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 8708 2 3 2 1 1 1 6}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) lumentis(8708) lumGeneric(2) lumInventoryMIB(3) lumInventoryMIBObjects(2) invPhysical(1) invPhysTable(1) invPhysEntry(1) invPhysParentRelPos(6)}
OID-IRI notation
  • /1/3/6/1/4/1/8708/2/3/2/1/1/1/6
  • /ISO/Identified-Organization/6/1/4/1/8708/2/3/2/1/1/1/6
  • /ISO/3/6/1/4/1/8708/2/3/2/1/1/1/6
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/8708/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprise/lumentis/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprises/8708/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • /iso/identified-organization/dod/internet/private/enterprises/lumentis/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/8708/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/lumentis/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • /iso/identified-organization/dod/internet/private/vendor-objects/8708/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • /iso/identified-organization/dod/internet/private/vendor-objects/lumentis/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • /iso/org/dod/internet/private/enterprise/8708/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • /iso/org/dod/internet/private/enterprise/lumentis/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • /iso/org/dod/internet/private/enterprises/8708/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • /iso/org/dod/internet/private/enterprises/lumentis/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • /iso/org/dod/internet/private/ldap-enterprise/8708/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • /iso/org/dod/internet/private/ldap-enterprise/lumentis/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • /iso/org/dod/internet/private/vendor-objects/8708/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • /iso/org/dod/internet/private/vendor-objects/lumentis/lumGeneric/lumInventoryMIB/lumInventoryMIBObjects/invPhysical/invPhysTable/invPhysEntry/invPhysParentRelPos
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
-1–2147483647

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.

Published row index: invPhysIndex.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.8708.2.3.2.1.1.1.6

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

invPhysParentRelPos OBJECT-TYPE
    SYNTAX      Integer32 (-1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An indication of the relative position of this
        'child' component among all its 'sibling'
        components. Sibling components are defined as
        invPhysEntries which share the same instance
        values of each of the invPhysContainedIn
        and invPhysClass objects.

        An NMS can use this object to identify the
        relative ordering for all sibling components
        of a particular parent (identified by the
        invPhysContainedIn instance in each sibling
        entry).

        This value should match any external labeling
        of the physical component if possible. For example,
        for a container (e.g., card slot) labeled as
        'slot #3', invPhysParentRelPos should have the
        value '3'.  Note that the invPhysEntry for the
        module plugged in slot 3 should have an
        invPhysParentRelPos value of '1'.

        If the physical position of this component
        does not match any external numbering or clearly
        visible ordering, then user documentation or
        other external reference material should be
        used to determine the parent-relative position.
        If this is not possible, then the the agent should
        assign a consistent (but possibly arbitrary)
        ordering to a given set of 'sibling' components,
        perhaps based on internal representation of the
        components.

        If the agent cannot determine the parent-relative
        position for some reason, or if the associated
        value of invPhysContainedIn is '0', then the
        value '-1' is returned. Otherwise a non-negative
        integer is returned, indicating the parent-relative
        position of this physical entity.

        Parent-relative ordering normally starts from
        '1' and continues to 'N', where 'N' represents
        the highest positioned child entity.  However,
        if the physical entities (e.g., slots) are labeled
        from a starting position of zero, then the first
        sibling should be associated with a
        invPhysParentRelPos value of '0'.  Note that this
        ordering may be sparse or dense, depending on agent
        implementation.

        The actual values returned are not globally
        meaningful, as each 'parent' component may use
        different numbering algorithms. The ordering is
        only meaningful among siblings of the same parent
        component.

        The agent should retain parent-relative position
        values across reboots, either through algorithmic
        assignment or use of non-volatile storage.
"
    ::= { invPhysEntry 6 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

An indication of the relative position of this 'child' component among all its 'sibling' components. Sibling components are defined as invPhysEntries which share the same instance values of each of the invPhysContainedIn and invPhysClass objects. An NMS can use this object to identify the relative ordering for all sibling components of a particular parent (identified by the invPhysContainedIn instance in each sibling entry). This value should match any external labeling of the physical component if possible. For example, for a container (e.g., card slot) labeled as 'slot #3', invPhysParentRelPos should have the value '3'. Note that the invPhysEntry for the module plugged in slot 3 should have an invPhysParentRelPos value of '1'. If the physical position of this component does not match any external numbering or clearly visible ordering, then user documentation or other external reference material should be used to determine the parent-relative position. If this is not possible, then the the agent should assign a consistent (but possibly arbitrary) ordering to a given set of 'sibling' components, perhaps based on internal representation of the components. If the agent cannot determine the parent-relative position for some reason, or if the associated value of invPhysContainedIn is '0', then the value '-1' is returned. Otherwise a non-negative integer is returned, indicating the parent-relative position of this physical entity. Parent-relative ordering normally starts from '1' and continues to 'N', where 'N' represents the highest positioned child entity. However, if the physical entities (e.g., slots) are labeled from a starting position of zero, then the first sibling should be associated with a invPhysParentRelPos value of '0'. Note that this ordering may be sparse or dense, depending on agent implementation. The actual values returned are not globally meaningful, as each 'parent' component may use different numbering algorithms. The ordering is only meaningful among siblings of the same parent component. The agent should retain parent-relative position values across reboots, either through algorithmic assignment or use of non-volatile storage.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

invPhysParentRelPos · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: invPhysParentRelPos

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "invPhysParentRelPos",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "1",
    ".",
    ".",
    "2147483647",
    ")",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"An indication of the relative position of this 'child' component among all its 'sibling' components. Sibling components are defined as invPhysEntries which share the same instance values of each of the invPhysContainedIn and invPhysClass objects. An NMS can use this object to identify the relative ordering for all sibling components of a particular parent (identified by the invPhysContainedIn instance in each sibling entry). This value should match any external labeling of the physical component if possible. For example, for a container (e.g., card slot) labeled as 'slot #3', invPhysParentRelPos should have the value '3'. Note that the invPhysEntry for the module plugged in slot 3 should have an invPhysParentRelPos value of '1'. If the physical position of this component does not match any external numbering or clearly visible ordering, then user documentation or other external reference material should be used to determine the parent-relative position. If this is not possible, then the the agent should assign a consistent (but possibly arbitrary) ordering to a given set of 'sibling' components, perhaps based on internal representation of the components. If the agent cannot determine the parent-relative position for some reason, or if the associated value of invPhysContainedIn is '0', then the value '-1' is returned. Otherwise a non-negative integer is returned, indicating the parent-relative position of this physical entity. Parent-relative ordering normally starts from '1' and continues to 'N', where 'N' represents the highest positioned child entity. However, if the physical entities (e.g., slots) are labeled from a starting position of zero, then the first sibling should be associated with a invPhysParentRelPos value of '0'. Note that this ordering may be sparse or dense, depending on agent implementation. The actual values returned are not globally meaningful, as each 'parent' component may use different numbering algorithms. The ordering is only meaningful among siblings of the same parent component. The agent should retain parent-relative position values across reboots, either through algorithmic assignment or use of non-volatile storage. \"",
    "::=",
    "{",
    "invPhysEntry",
    "6",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -1,
            2147483647
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "An indication of the relative position of this 'child' component among all its 'sibling' components. Sibling components are defined as invPhysEntries which share the same instance values of each of the invPhysContainedIn and invPhysClass objects. An NMS can use this object to identify the relative ordering for all sibling components of a particular parent (identified by the invPhysContainedIn instance in each sibling entry). This value should match any external labeling of the physical component if possible. For example, for a container (e.g., card slot) labeled as 'slot #3', invPhysParentRelPos should have the value '3'. Note that the invPhysEntry for the module plugged in slot 3 should have an invPhysParentRelPos value of '1'. If the physical position of this component does not match any external numbering or clearly visible ordering, then user documentation or other external reference material should be used to determine the parent-relative position. If this is not possible, then the the agent should assign a consistent (but possibly arbitrary) ordering to a given set of 'sibling' components, perhaps based on internal representation of the components. If the agent cannot determine the parent-relative position for some reason, or if the associated value of invPhysContainedIn is '0', then the value '-1' is returned. Otherwise a non-negative integer is returned, indicating the parent-relative position of this physical entity. Parent-relative ordering normally starts from '1' and continues to 'N', where 'N' represents the highest positioned child entity. However, if the physical entities (e.g., slots) are labeled from a starting position of zero, then the first sibling should be associated with a invPhysParentRelPos value of '0'. Note that this ordering may be sparse or dense, depending on agent implementation. The actual values returned are not globally meaningful, as each 'parent' component may use different numbering algorithms. The ordering is only meaningful among siblings of the same parent component. The agent should retain parent-relative position values across reboots, either through algorithmic assignment or use of non-volatile storage."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.8708)

Carlsson Martin

Siblings (17)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.8708.2.3.2.1.1.1.1 invPhysIndex00
1.3.6.1.4.1.8708.2.3.2.1.1.1.2 invPhysDescr00
1.3.6.1.4.1.8708.2.3.2.1.1.1.3 invPhysVendorType00
1.3.6.1.4.1.8708.2.3.2.1.1.1.4 invPhysContainedIn00
1.3.6.1.4.1.8708.2.3.2.1.1.1.5 invPhysClass00
1.3.6.1.4.1.8708.2.3.2.1.1.1.7 invPhysName00
1.3.6.1.4.1.8708.2.3.2.1.1.1.8 invPhysHardwareRev00
1.3.6.1.4.1.8708.2.3.2.1.1.1.9 invPhysFirmwareRev00
1.3.6.1.4.1.8708.2.3.2.1.1.1.10 invPhysProductDataRev00
1.3.6.1.4.1.8708.2.3.2.1.1.1.11 invPhysSerialNum00
1.3.6.1.4.1.8708.2.3.2.1.1.1.12 invPhysMfgName00
1.3.6.1.4.1.8708.2.3.2.1.1.1.13 invPhysModelName00
1.3.6.1.4.1.8708.2.3.2.1.1.1.14 invPhysIsFRU00
1.3.6.1.4.1.8708.2.3.2.1.1.1.15 invPhysSoftwareRev00
1.3.6.1.4.1.8708.2.3.2.1.1.1.16 invPhysSoftwareProduct00
1.3.6.1.4.1.8708.2.3.2.1.1.1.17 invPhysClei00
1.3.6.1.4.1.8708.2.3.2.1.1.1.18 invPhysAid00